29
SERENE SC112G
Replacement Procedures
Service Manual
Compressor
The compressor is located on the bottom layer (level one) of the refrigeration
system. If the compressor is causing excessive noise, check the mountings
to ensure there is no damage to the rubber or the washers, nuts and screws.
Before replacing the compressor, check all plugs and connections and
ensure the compressor electrics are operating correctly (see below). The
compressor must be supplied with consistent voltage over 220 volts. Ensure
the voltage does not drop at start-up. If the voltage does drop, ensure the
refrigeration system has a direct power supply (not from a multi-box or
extension cord).
To access the compressor
Compressor
Electrics
The compressor electrics are located on the side of the compressor and
include the start capacitor, motor protector and run capacitor. The complete
set is supplied as a spare part if required.
To access the compressor electrics
1. Isolate the chiller from the power supply, seperate the top cabinet assembly
from the bottom refrigeration system and gain access to level one of the
refrigeration system (see page 25).
2. Service as necessary.
Figure 6: Compressor
electrics
Run capacitor
PTC starting device
Motor protector
1. Isolate the chiller from the power supply, seperate the top cabinet assembly
from the bottom refrigeration system and gain access to level one of the
refrigeration system (see page 25).
2. Lever the compressor
electrics cover off with a
slotted screwdriver.
3. Service as necessary.