29
TCE1000N
Replacement Procedures
Service Manual
Dedicated hydrocarbon gauges.
Intrinsically safe hydrocarbon combustible gas leak detector.
Intrinsically safe scales to 1 gram accuracy.
Well ventilated work area.
Refrigeration
Unit Assembly
The refrigeration unit is a top mounted, electronically controlled removable
unit.
For safety and compliance, only SKOPE supplied parts specifically for this
appliance may be used for repairs. Other parts may appear to be suitable,
but may not be approved or safe for use in an appliance with hydrocarbon
refrigerant.
The unit must only be used on a SKOPE Hydrocarbon compliant cabinet.
Refer to the cabinet rating label to determine if the cabinet is suitable for use
with a hydrocarbon unit. The rating label MUST state refrigerant as R290. If
the label states a different refrigerant, or does NOT state a refrigerant, it is
NOT suitable for a hydrocarbon unit.
For servicing or transportation, the refrigeration unit unplugs and lifts off the
cabinet. Some minor servicing can be performed without removing the
refrigeration unit.
The model and serial number are both printed on the unit rating/serial
number label attached to the top of the side of the cover.
WARNING
The hydrocarbon unit must only be used on an hydrocarbon
compliant cabinet.