5
SKOPE B1200-2/B1200G-2
Installation
User Manual
Positioning the Cabinet
Chiller
Location
The location of the chiller may be the single most important decision that will
extend its life and ensure economical, high performance. We recommend
that you put the chiller in the coolest place possible because it will use less
power and last longer.
Allow adequate space for doors to open and close properly. Self-closing
doors have internal torsion bars pretensioned at the factory, and must be
unobstructed. Ensure the cabinet sits on a level surface so that the doors
shut and correctly seal. Level footing also prevents the condensate tray from
overflowing.
Ventilation
Ensure there is always at least a 50mm gap around the back, top and
underside of the cabinet. Keep the ventilation slots in the front panel clear at
all times,
never
store cardboard cartons or other objects in front of the
chiller.
Before
Operating
Ensure both rear spacers are rotated outwards and fully tightened. This will
provide the necessary air gap at the rear of the cabinet for correct operation.
Power Cord
The chiller has a flexible power cord fitted with a 3-pin plug, which exits the
rear of the cabinet at floor level. Pull the power cord around so that it’s not
trapped before you position the cabinet.
CAUTION
To prevent over heating and conserve energy, ensure air flows
freely all around the chiller - including front, back, top and
underside (minimum 50mm gap).
Back of Chiller
Power Cord
Rear Spacer