Surface Back Pressure Regulator
BPR10000MFB-MA
Operations and Maintenance Instructions
2
A
BOUT
S
KO
F
LO
Our experience and track record speak for themselves.
SkoFlo has delivered over 20,000 valves since 1988. We are
the only company that proves our products by testing in
surface applications before deploying them subsea. The
result is that SkoFlo valves have amassed over 25 million
continuous operating hours. This level of experience is
unparalleled and provides the basis for being the solution
provider to our served market.
SkoFlo Surface Back Pressure Regulator (BPR) is the
industry leader in the oil and gas marketplace and
regulating pump discharge pressure in chemical injection
systems.
G
ENERAL
I
NFORMATION
1.
Product Overview
The BPR is designed to maintain a constant set pressure in
pump discharge lines feeding the chemical injection
system. As pressure rises in the pump discharge line, the
BPR will maintain pressure levels at a Set Point while
allowing the unused fluid to return to the chemical
holding tank.
BPRs should be used in any pump discharge line where
the pressure must remain at a constant level and unused
fluid can be routed back to the fluid holding tank.
BPRs are not designed to be used as Pressure Safety
Devices.
BPRs provide a constant pressure to the system with
continuous spill-off to the chemical tank that is
independent of the flow rate. The BPR10000MFB series has
a maximum operating pressure of 10,000psi and supports
a flow range of 0.5 – 15 GPM.
2.
Guidelines for Using this Manual
The following instructions are provided to ensure a safe
and proper installation.
−
Read all instructions prior to installation and operation
of this product.
−
Follow all warning and caution notes.
−
Install this product as specified in the instructions
provided by SkoFlo.
−
Prior to use, educate personnel in the proper
installation, operation, and maintenance of this
product.
−
Only use replacement parts specified by SkoFlo.
3.
Warning, Caution, Notice
Throughout this manual there are steps and procedures
which, if not followed, may result in a hazard. The
following flags are used to identify the level of potential
hazard.
! WARNING
WARNING IS USED TO INDICATE THE PRESENCE OF A
HAZARD WHICH CAN CAUSE SEVERE INJURY, DEATH, OR
SUBSTANTIAL PROPERTY DAMAGE IF THE WARNING IS
IGNORED.
! CAUTION
CAUTION IS USED TO INDICATE THE PRESENCE OF A
HAZARD WHICH CAN CAUSE INJURY OR PROPERTY
DAMAGE IF THE WARNING IS IGNORED.
! NOTICE
NOTICE IS USED TO NOTIFY PEOPLE OF INSTALLATION,
OPERATION, OR MAINTENANCE INFORMATION,
WHICH IS IMPORTANT BUT NOT HAZARD RELATED.
4.
Abbreviations and Acronyms
BPR Back Pressure Regulator
BOM Bill of Materials
GA
General Arrangement
MA
Manual
NPT National Pipe Thread
PPE Personal Protective Equipment
PSI
Pounds per Square Inch
Summary of Contents for BPR10000MFB Series
Page 8: ...Surface Back Pressure Regulator BPR10000MFB MA Operations and Maintenance Instructions 7...
Page 11: ...Surface Back Pressure Regulator BPR10000MFB MA Operations and Maintenance Instructions 10...
Page 13: ...Surface Back Pressure Regulator BPR10000MFB MA Operations and Maintenance Instructions 12...
Page 15: ...Surface Back Pressure Regulator BPR10000MFB MA Operations and Maintenance Instructions 14...