INSTRUCTION MANUAL 

for installation and operation of room heaters 

and inset appliances fired by solid fuel 

 
 
 

 

 
 
 
 

SKLADOVA TEHNIKA 

25 Sveti Knyaz Boris I St. 
5100 Gorna Oryahovitsa 
Republic of Bulgaria 
phone: +359 618 60576 
e-mail: [email protected] 
www.st-bg.com 

Summary of Contents for ??dena

Page 1: ...stallation and operation of room heaters and inset appliances fired by solid fuel SKLADOVA TEHNIKA 25 Sveti Knyaz Boris I St 5100 Gorna Oryahovitsa Republic of Bulgaria phone 359 618 60576 e mail info...

Page 2: ...3 3 Appliance operation 4 4 Important directions for fire precaution and safety regulations 6 5 Cleaning 7 6 Possible defects and their causes 7 Appendix 1 8 Appendix 2 10 Installation diagram for a...

Page 3: ...lass or stone plates If a heat resistant plate is used it should come out 50 cm in front and 30 cm from both sides measured from the fire door of the fireplace If there are any combustible materials o...

Page 4: ...The mounted glass is ceramic and it stands up to 850 C so it cannot be damaged by the temperature which is achieved when the appliance is operating But it could be damaged by a mechanical influence wh...

Page 5: ...uct The inner part of the oven is painted with heat resistant paint which can be damaged by boiled over food and grease It is advisable to use deeper dishes with lids In order to obtain even baking th...

Page 6: ...e appliance In this case for the right burning to be achieved it is necessary to let additional air into the room 3 7 Heating during the transitional period For the good functioning of the appliance i...

Page 7: ...ir causes At ignition the appliance is smoking not enough flue draught pressure The chimney and the flue pipes are not sealed The chimney is with wrong size open doors of another appliance connected t...

Page 8: ...65 125 Lotos Max B 25 4 19 77 48 251 16 27 12 40 40 80 1 31 1 6 8 650 615 1185 220 Lotos Max FT 14 14 69 80 68 13 318 13 4 12 278 15 8 12 40 40 80 3 9 3 8 650 600 1070 155 Lotos Max FTB 18 5 14 77 48...

Page 9: ...7 75 53 249 6 9 12 30 35 80 2 3 550 495 1095 125 Mars BO 3 5 5 80 96 229 6 98 12 25 20 80 2 1 2 57 550 500 1095 175 Jupiter 7 77 2 242 7 99 12 40 40 120 2 3 508 475 1040 156 Jupiter BO 3 5 80 96 229...

Page 10: ...er 2 bar Deaeration in each branch and component of the installation should be ensured in each moment of its operation and the appliance as well In the installation immediately near the integral boile...

Page 11: ...4 Filter 15 Turn cock for filling and draining the system INSTALLATION DIAGRAM for connecting of room heaters and inset appliances fired by solid fuel with integral boilers type BO close heating syste...