IFOV =2.77 mRad (Theoretical with 160x120 Detector and standard 25˚x19˚ lens)

                                                   Detect 1in. target @ 30.8ft. 

 

IFOV =1.15 mRad (Theoretical with 380x280 Detector and standard 25˚x19˚ lens)

                                                   Detect 1in. target @ 72.5ft. 

7. 

 

PAUSE and SAVE IMAGE: 

To save an image, depress the S key. It will then pause and show a visual image 

and you can either Save or Cancel the saving by using the ►◄ buttons and then depress On/Off/Menu button. 

Note:

 In the System Setup menu, you can also set the camera to save an image when the trigger is depressed.

 

 

8. 

 

RECALL IMAGE: 

Depress the On/Off/Menu button, highlight File with the ▲▼ buttons then depress the ► button 

and highlight Open and depress the On/Off/Menu button. The last image to be saved will be shown, using the ►◄ 
buttons you can go forward or backward through the images. To go back to a live image, depress the C button. 

 

 

9. 

 

PALETTE: 

Depress A twice, and the color bar is highlighted, then use the ►◄ buttons to scroll through the 

palettes until you find the one you want, and let it time out (2-3 seconds) to select it.

 

 

10. 

 

RANGE: 

The TKTI21 has a range of: -1°F--660°F (-20°C--350°C). The TKTI31 has two ranges: -4°F--356°F (-

20°C--180°C) and 212°F--1112°F (100°C--600°C). To change range, depress On/Off/Menu button, ▼ to select 
Setup, ► to Measurement, Enter on Measurement then the ►◄ buttons to choose the range you want, then Enter.

 

.  

11. 

 

EMISSIVITY:

 

Depress On/Off/Menu button, ▼ to select Setup, ► to Infrared Settings, depress Enter then the 

►◄ buttons to choose the proper emissivity. 

Note:

 Selecting Customize, then using the ►◄ buttons will scroll 

through a material list. Depress Enter when you find the material you choose.

 

 

12. 

 

BACKGROUND:

 

Depress On/Off/Menu button, ▼ to select Setup, ► to Infrared Settings, then ▼ to TReflect, 

use the ►◄ buttons to turn it on, then ▼ to highlight the value, then use the ►◄ buttons to the correct value and 
depress Enter.

 

 

 

 

TKTI-21 

 
 
 
 

TKTI-31 

Reviews: