SKF Spandau Pumpen PSR 02 Assembly Manual And Corresponding Operating Manual Download Page 4

Information on the EC Declaration of Conformity and the EC Declaration of Incorporation 

Page 4 

 
 
 

 

EN 

 

EN 

Information on the EC Declaration of Conformity and the EC Declaration of 
Incorporation

For the following product: 
 
Centrifugal pump 
 
Belonging to the following series: 

MFEx model 

PSR… 

 
We hereby confirm that this product complies with 
the relevant safety requirements specified in the 
applicable directives of the Council concerning the 
approximation of the laws of the Member States, 
viz.: 
 

 

Machinery Directive 2006/42/EC 

 

Low Voltage Equipment 2006/95/EC 

 

Electromagnetic Tolerance 2004/108/EC 

 
...   
 

Information: 

(a)

 

This declaration certifies compliance with the 
named regulations but does not guarantee 
characteristics. 

(b)

 

The safety instructions in the documentation 
enclosed with the product must be observed. 

(c)

 

The commissioning of the certified products is 
prohibited until it has been ensured that the 
machine, vehicle, or similar unit into which the 

product has been installed complies with the 
conditions and requirements of the applicable 
directives. 

(d)

 

The operation of the products on a non*
standard mains voltage as well as non*
compliance with installation instructions can 
affect EMC characteristics and electrical safety. 

 
Furthermore: 
 

 

The aforementioned product is intended, in 
accordance with 

EC Machinery Directive 

2006/42/EC, Appendix II, Part B

, to be 

installed in a machine/assembled with other 
machines to form a superordinate machine. It 
may not be commissioned for applications 
within the scope of this EC directive until it has 
been determined that the machine in which 
this product is installed complies with the 
conditions of the aforementioned directive. 

 

 

The product may only be used as intended and 
in accordance with the instructions in the 
documentation with due observance of 

EC 

Directive 97/23/EC regarding pressure 
equipment

. Please closely observe the 

following: 

 

The product is neither designed nor approved for 
use in conjunction with fluids belonging to Group 1 
(hazardous fluids) as defined in Article 2, 
Paragraph 2 of Directive 67/548/EC of 27 June 
1967. 
The product is neither designed nor approved for 
use in conjunction with gases, liquefied gases, 
gases dissolved under pressure, vapours, or fluids 
with a vapour pressure of more than 0.5 bar above 
normal atmospheric pressure (1013 mbar) at the 
maximum permitted temperature. 
 
Products supplied by SKF Lubrication Systems 
Germany GmbH do not reach the limit values listed 
in Article 3, Paragraph 1, Points 1.1 to 1.3 and 
Paragraph 2 of Directive 97/23/EC. This means 
that they are not subject to the requirements of 
Appendix I of this Directive. They therefore do not 
have a CE mark as per Directive 97/23/EC. SKF 
Lubrication Systems Germany GmbH classifies 
products in accordance with Article 3, Paragraph 3 
of the directive. 
 
The Declaration of Conformity and Incorporation 
forms an integral part of the documentation and is 
delivered with the product. 

Summary of Contents for Spandau Pumpen PSR 02

Page 1: ...Product name Centrifugal pump Product range PSR Original assembly manual and corresponding operating manual in accordance with EC Machinery Directive 2006 42 EC Version 03...

Page 2: ...mentation is protected by copyright The photo mechanical reproduction copying and distribution of this documentation or parts thereof by means of processes such as data processing data carriers and da...

Page 3: ...unction 11 5 Assembly instructions 12 5 1 Positioning 12 5 2 Connection dimensions 14 5 3 Laying the pipes 14 5 4 Connection of pipelines 14 5 5 Screwing the pump onto the reservoir 14 5 6 Electrical...

Page 4: ...led in a machine assembled with other machines to form a superordinate machine It may not be commissioned for applications within the scope of this EC directive until it has been determined that the m...

Page 5: ...examples below must be observed Rotational direction arrow Fluid connection label Such signs must be kept in a legible state Keywords in safety information and their meanings The responsibility is yo...

Page 6: ...Product name Centrifugal pump Product range PSR Original assembly instructions in accordance with EC Machinery Directive 2006 42 EC...

Page 7: ...be implemented in accordance with the characteristics of the conveyed media The provided safety functions must not be damaged taken out of services made useless or replaced by any parts other than th...

Page 8: ...ion regulations and assembly measures They are entitled to carry out the required tasks and to recognize and thus avoid any dangers that might otherwise occur A definition of what constitutes a qualif...

Page 9: ...ng limit values must be observed if using contaminated or high viscosity fluids Grain size Max of 2 mm for PSR 02 04 Dirt content Max 50 g m3 for PSR 02 04 Kinematic viscosity Max 20 mm2 s In the case...

Page 10: ...ar Size 02 04 06 2 m h 4 m h 6 m h No of stages 02 30 No of active stages Material type G C T Cast iron standard GG with chemical surface sealing GG coated with paint Seal type B G Sealing bushing Fac...

Page 11: ...es 6 are attached using tie rods 5 The pump port contains the bearing for the pump shaft and seal The pressure port 4 and connecting flange 3 for assembly on a tank are also located on the pump port A...

Page 12: ...ce instructions of the operator must be observed when carrying out all assembly work on machines 5 1 Positioning PSR immersion pumps are designed to be installed in a vertical position in a tank If yo...

Page 13: ...e mounted in a way that protects it from humidity and vibrations It should also be easily accessible so that all other installation work can be carried out without problems Make sure that there is a s...

Page 14: ...r check valves Unavoidable cross section changes in conveying lines must have smooth transitions Sudden changes of direction are to be avoided The lines must be leak tight and laid in a way that preve...

Page 15: ...ith the circuit diagram in the motor junction box In the case of a pump which has been left stored without being used for a relatively long period of time in a damp room we recommend that you measure...

Page 16: ...Product name Centrifugal pump Product range PSR Operating manual...

Page 17: ...n a dry dust free low vibration veff 0 2 mm s environment In the case of a relatively long period of storage the bearing grease service life decreases In the case of storage lasting more than 12 month...

Page 18: ...at there is no dirt in the reservoir or pipeline system and that the upstream filters are working properly PSR Place the pump into operation as follows If there is a shut off valve on the pressure sid...

Page 19: ...t down the described product by disconnecting the electrical and hydraulic supply connections For more information see General information in this assembly manual If you wish to shut down the product...

Page 20: ...askets should be regularly checked for dirt and cleaned replaced as necessary Make sure that there are no foreign bodies dust or similar in the housing of the pump motor in order to ensure good heat e...

Page 21: ...t slightly Undo the cylinder head screw 3 on the hydraulics side The hydraulics are then separated from the drive Removing the hydraulics unit Undo the spray ring 5 This is a hat shaped stainless stee...

Page 22: ...e edge of the bottom running wheel and the edge of the bottom chamber opening Tightening the clamp coupling Once the running gap has been set correctly you can attach the shaft to the clamp coupling a...

Page 23: ...Cross section of PSR coupling pump 1 Plastic cap 4 Pump shaft 6 1 Counter ring 8 Running wheel 2 Clamp coupling 5 Spray ring 7 Sealing bushing 9 Tie rod 3 Cylinder hear screw 6 O ring 7 1 Slide ring...

Page 24: ...he replacement of parts etc may only be carried out by qualified and trained experts Repair work may only be carried out by qualified experts once all assemblies have been disconnected from the power...

Page 25: ...rcuit breaker again Switching contact or motor coils are defective Replace any defective parts Motor circuit breaker triggers immediately when you switch the system on Fuse is blown A phase is missing...

Page 26: ...sary Incorrect installation See Assembly instructions Pump is running but not conveying medium Suction opening blocked Check the suction opening and clean it if necessary The medium may be heavily con...

Page 27: ...Conveying systems are under pressure when they are being operated They must therefore be depressurized before assembly maintenance or repair works begin and before any changes to the system are made...

Page 28: ...inless steel 1 4571 Impeller Stainless steel 1 4305 Intermediate chamber Stainless steel 1 4301 Tension anchor Stainless steel 1 4057 Bushing Stainless steel 1 4301 Pump bottom Stainless steel 1 4308...

Page 29: ...al data Page 29 EN 11 4 Dimensions PSR Additional equipment For extension pipe For intake strainer k 114 mm to 182 mm l 223 mm to 530 mm m 176 mm to 257 mm t 137 mm to 747 mm q 140 mm Weight 13 1 kg t...

Page 30: ...11 Technical data Page 30 EN 12 Notes...

Page 31: ...Page 31 EN...

Page 32: ...mp units which are marketed by SKF Lubrication Systems Germany GmbH are not approved for use in conjunction with gases liquefied gases gases dissolved under pressure vapours and fluids with a vapour p...

Reviews: