SKF LINCOLN 85831 Assembly Manual Download Page 3

Safety

Read and carefully observe these installation 
instructions before installing, operating or 
troubleshooting the assembly. The assembly 
must be installed, maintained and repaired 
exclusively by persons familiar with the 
instructions.

Install the assembly only after safety 

 instructions and this guide have been read 
and are completely understood.

Adequate personal protection must be 

used to prevent splashing of material on the 
skin or in the eyes.

 Always disconnect power source (elec-

tricity, air or hydraulic) from the pump when 
it is not being used.

This equipment generates very high 

grease pressure. Extreme caution should be 
used when operating this equipment as  
material leaks from loose or ruptured com-
ponents can inject fluid through the skin and 
into the body. If any fluid appears to pene-
trate the skin, seek attention from a doctor 
immediately.

Do not treat injury as a simple cut. Tell  

attending doctor exactly what type of fluid 
was injected.

Any other use not in accordance with  

instructions will result in loss of claim for 
warranty or liability. 

•  Do not misuse, over-pressurize, modify 

parts, use incompatible chemicals, fluids, 
or use worn and/or damaged parts.

•  Do not exceed the stated maximum 

working pressure of the pump or of the 
lowest rated component in your system.

•  Always read and follow the fluid manufac-

turer’s recommendations regarding fluid 
compatibility, and the use of protective 
clothing and equipment.

•  Failure to comply may result in personal 

injury and/or damage to equipment.

Table 1

Model

Power source Drum size

85831

230 V AC

120 lbs. 

(54 kg)

85832

230 V AC

400 

(181 kg)

85833

120 V AC

120 lbs. 

(54 kg)

85834

120 V AC

400 

(181 kg)

85835

24 V DC

120 lbs. 

(54 kg)

85836

24 V DC

400 

(181 kg)

Use of this manual

Overview

This manual details the procedure that must 
be followed while installing,the electric vent 
valve assembly on a 120 lb. 

(54 kg)

 

or 

400 lb. 

(181 kg)

 drum with a FlowMaster II 

rotary driven AC electric pump.

All required parts, tools, and equipment 

needed to complete the installation of the 
electric vent valve assembly are defined and 
listed within this manual.

Review of the parts list and nomenclature 

is recommended before starting  
disassembly or operation.

General description 

and information

The electric vent valve assembly is intended 
to be used with a drum mounted 
FlowMaster II electric pump in a Centro-
Matic lube system. The 2-way normally 
open solenoid vent valve is to be wired in 
parallel with the motor on an electric 
FlowMaster II pump. See wiring diagram in 
appropriate pump owner’s manual.

 

Inspection

If over pressurizing of the equipment is  
believed to have occurred, contact the  
factory authorized warranty and service 
center nearest you for inspection of the 
pump.

Specialized equipment and knowledge is  

required for repair of this pump.

Annual inspection by the factory 

authorized warranty and service center 
nearest you is recommended.

Damaged Pumps

Do not use any pump that appears to be 
damaged, badly worn or operates 
abnormally. Remove the pump from service 
and contact the factory authorized warranty 
and service center nearest you for repairs.

A list of authorized warranty and  

service centers is available upon request.

3

Summary of Contents for LINCOLN 85831

Page 1: ...over 85757 120 lb and 85758 400 lb drum Assembly guide Date of issue December 2012 Form number 404475 Section C8 Page 368A Read manual prior to installation or use of this product Keep manual nearby f...

Page 2: ...Contents Safety 3 Use of this manual 3 Overview 3 General description and information 3 Assembly 4 Parts 6 Lincoln industrial standard warranty 9 2...

Page 3: ...amage to equipment Table 1 Model Power source Drum size 85831 230 V AC 120 lbs 54 kg 85832 230 V AC 400 181 kg 85833 120 V AC 120 lbs 54 kg 85834 120 V AC 400 181 kg 85835 24 V DC 120 lbs 54 kg 85836...

Page 4: ...ure 2 and thread the street elbow 11 onto the reducer nipple 17 and tighten hand tight 2 Insert reducer nipple 17 into block valve 15 and tighten hand tight 3 Thread adapter 16 into block valve 15 4 I...

Page 5: ...screws 19 9 Refer to page 3 figure 1 and connect hose assembly 12 to both elbows 11 10 Assemble hose assembly 10 to elbow 13 and to vent fitting 5 11 Thread safety unloader 6 into internal run tee 7...

Page 6: ...12018 1 17 Reducer nipple 14727 1 18 Lock washer 5 16 66246 2 19 Hex head screw 5 16 18 x 1 2 50034 2 20 DIN connector 276904 1 21 Solenoid coil See below 1 22 Cartridge valve 276899 1 23 Vent valve...

Page 7: ...1 4 5 6 7 8 9 10 11 12 13 14 15 16 17 11 18 19 2 3 Fig IPB 1 7...

Page 8: ...12 13 14 15 16 17 11 18 1 2 3 4 5 6 7 8 9 10 11 19 Fig IPB 2 8...

Page 9: ...e sale resale or use of any Lincoln equipment shall in no event exceed the purchase price Some jurisdictions do not allow the exclusion or limitation of inci dental or consequential damages therefore...

Page 10: ...nsequential arising out of the use of the information contained herein SKF PUB LS I4 13474 EN December 2012 Form 404475 Bearings and units Seals Lubrication systems Mechatronics Services The Power of...

Reviews: