9
SKF SYSTEM 24 - LAGD 60 / LAGD 125
5. Problem solving
Problem
Possible causes
Action
Lubricator does
not dispense or
dispenses too slowly
Incorrect adjustment
Adjust the dispense rate
Lubricator is not activated
Activate the lubricator time
set dial
Lubrication channels are
blocked
Clear the blockage by
forcing grease with a
grease gun through the
lubrication channels
The resistance is too high
Make sure that:
- excessive grease can
escape
- supply lines are not
longer than 300 mm
- supply lines have a inner
diameter of 6 mm
- Lubrication point is
suitable for gas driven
lubricators
Lubricant dispenses too
quickly
Incorrect adjustment
Adjust the dispense rate
Short term temperature
peak
No corrective action
needed
Air between the piston
and the lubricant
Installed longer period than
the selected time
Replace the unit
The ambient temperature
is more than the acceptable
limit
Replace the unit and
protect the unit against
high ambient temperatures
Lubricator neck breaks
Too high vibration or
impact
Support the unit with
the clamp LAPC 50 or
protection plate LAPP 4
If the lubricator still fails to operate, contact your local SKF SYSTEM 24 supplier.
Material safety data sheets for the LAGD 60/125 and for the lubricants used can be found
at www.mapro.skf.com.
Engl
ish
Summary of Contents for LAGD 125
Page 2: ......
Page 4: ......
Page 14: ...12 SKF SYSTEM 24 LAGD 60 LAGD 125...
Page 24: ...22 SKF SYSTEM 24 LAGD 60 LAGD 125...
Page 34: ...32 SKF SYSTEM 24 LAGD 60 LAGD 125...
Page 44: ...42 SKF SYSTEM 24 LAGD 60 LAGD 125...
Page 54: ...52 SKF SYSTEM 24 LAGD 60 LAGD 125...
Page 64: ...62 SKF SYSTEM 24 LAGD 60 LAGD 125...
Page 74: ...72 SKF SYSTEM 24 LAGD 60 LAGD 125...
Page 84: ...82 SKF SYSTEM 24 LAGD 60 LAGD 125...
Page 90: ...88 SKF SYSTEM 24 LAGD 60 LAGD 125 4 4 1 10 C 40 C...
Page 92: ...90 SKF SYSTEM 24 LAGD 60 LAGD 125 1 2 3 6 1 2 3 4 150110 160603...
Page 94: ...92 SKF SYSTEM 24 LAGD 60 LAGD 125...
Page 102: ...100 SKF SYSTEM 24 LAGD 60 LAGD 125 1 2 3 6 1 2 3 4 EU 150110 EU 160603...