7. Functional description in single-line systems
7.2 Functional description of single-line
system with KFGS pump unit
The general functional description for single-
line systems with a KFG pump unit also applies
for the design with KFGS pump control.
The control unit integrated into the pump
housing allows the following additional con-
iguration, monitoring and connectivity options:
Interval time and pump cycle time can be
adjusted independently, including on
monitored systems
Recording of remaining intervals and
remaining lubrication times
Recording of fault notiications
(diagnostics memory)
Data backup in case of voltage failure
Non-volatile memory with PIN code
protection
Connectivity for pressure switch
Fill level monitoring, lubrication cycle is
stopped and fault notiication shown on
display in case level falls below minimum
3
4
5
1
2
M
6
Legend to figure of KFGS single-line system
1 Pump unit with pump element and ill level monitoring
2 Pressure regulating valve
3 Valve for pressure build-up and relief
4 Single-line distributor
5 Pressure gauge for pressure build-up monitoring (optional)
6 Pressure switch for pressure build-up monitoring
Single-line system with a lubrication zone using a 3/2 directional solenoid valve