background image

チコーエアーテック株式会社

Copyright CHIKO AIRTEC CO., LTD. 2009

4

1

製品使用上のご注意

Cautions on Using Product

1.1

全般

General

設置、接続、運転、操作、点検、故障診断の作業は、取扱説明書の内容に従い、適切に行って下さい。
誤った作業を行うと、火災・感電・けがの原因になります。

Perform installation, connection, operation, manipulation, inspection and failure diagnosis work properly in
accordance with the instruction manual. Incorrect work may cause fire, electrical shock and injury.

1.2

運搬・設置・保管・輸送の条件

The condition of installation and transportation and safekeeping

輸送・保管については安全な場所で、温度

-10

℃~

60

℃ 湿度

80%

以下の範囲として下さい。

For transport and storage, keep in a safe place, with a temperature range of -10 to +60

and humidity below

80%.

本機を運搬、設置、使用する際は、二人以上で行って下さい。落下などにより、けがをする恐れがあります。

During carrying-in and installation, use suitable carrying-in equipment or enlist the help of others when carrying
heavy objects to prevent an accident. There is danger of injury due to falling.

回転機器が内蔵されていますので、水平で振動の無い場所に設置して下さい。

Rotary equipment is built into the product. Install the product in a horizontal place without vibrations.

爆発・引火性ガス・腐食の危険がある場所や、水のかかる場所、可燃物のそばでは使用しないで下さい。

Do not use the product in places with explosive or flammable gas, with corrosion risk, with water splashes or
near combustible substances.

本機は、屋内クリーンルーム内 又は、清浄度の高い工場に設置することを前提とした構造となっていますので、屋外な
どには設置しないで下さい。

The product is designed to be installed in an indoor clean room or highly cleaned factory. Do not install it
outdoors.

常温(周囲温度

0

40

/

湿度

80

%以下)で、結露しない場所に設置して下さい。高温・結露は、電気部品の故障、

感電の原因になります。

Install the product in a place without dew condensation at room temperature (ambient temperature: 0 to 40ºC,
humidity: 80% or less). High temperature and dew condensation may cause electrical parts to fail and may
cause an electrical shock.

排気口は十分なスペース(排気口より

100

㎜以上)を設けて下さい。排気口を塞ぐと正規の吸引力が発揮できません。

また、ボックス内部で十分な冷却が行われないため、モータ焼けや電気部品の故障原因となります。

Provide sufficient space around the exhaust port (100 mm or more).
Clogging the exhaust port disables the regular suction force, and may cause motor burning and electrical part
failure due to insufficient cooling inside the product.

フィルタの交換、メンテナンスのしやすい場所に設置して下さい。
(フィルタ交換のため、本体正面から

500

㎜以上のスペースが必要です。)

Install the product in a place where filter replacement and maintenance can be performed easily.
(To replace filters, a space of 500 mm or more is required from the main body front face.)

本機は歩行面から

0.2

2

mの範囲で設置してください。

Install the product in a place 0.2 to 2.0 m from the walking surface.

本機の設置標高は

1,000

m以下です。

The installation height of the product is 1,000 m or less

設置区分は汚染度Ⅱ

(

製造工場

)

です。

The installation classification is “Contamination level

(manufacturing plant).

1.3

接続

Connection

接続は、確実におこなって下さい。ケーブルを無理に曲げたり、引っ張ったりしないで下さい。
火災・感電の原因になります。

Connect the product securely.
Do not bend or pull cables forcibly. Forcible bending or pulling may cause a fire and electrical shock.

異なった電源で使用しないで下さい。また、アース線を接続してお使い下さい。

Use the correct power supply, and connect the ground wire.

電源の過電圧カテゴリーは区分Ⅲです。(産業用装置など)

The category of over-voltage of the power supply is division

(industrial device).

Summary of Contents for SKV-250AT-ACC

Page 1: ...is instruction manual thoroughly and handle this SK Series machine correctly so that you can use it safely for a long time and enjoy its full performance Symbols used in this manual WARNING This symbo...

Page 2: ...osene paint etc Explosive dust Aluminum magnesium titanium zinc epoxy etc Dust containing sparks Dust containing sparks generated by high speed cutters grinders welding machines etc Fire sources Cigar...

Page 3: ...T AT panel 7 4 3 Remote connector 9 4 4 Confirmation before operation 9 4 5 Operation procedure 10 5 Remote Cable Sold Separately 11 5 1 Electrical circuit diagram 11 5 2 Remote Cable 11 5 3 Color and...

Page 4: ...y Do not install it outdoors 0 40 80 Install the product in a place without dew condensation at room temperature ambient temperature 0 to 40 C humidity 80 or less High temperature and dew condensation...

Page 5: ...repair 1 6 Disposal Dispose of the product properly as industrial waste 2 Confirmation and Preparation at Arrival After unpacking make sure that all parts are provided Contact our company immediately...

Page 6: ...e 1 Active carbon Colliding with granulated active carbon collects the particles passed through the primary filter and odor is removed carbon particle into the blower Main filter Collecting Adsorbing...

Page 7: ...When the filter replacement indicator lamp red turns ON replace the primary filter filter bag If the filter replacement indicator lamp does not turn OFF even after replacement of the primary filter f...

Page 8: ...eases by 1 level Minimum suction level Approximately 60 Hi 1 1 100 Hi switch Every time this switch is pressed the performance increases by 1 level Maximum suction level 100 ON switch and OFF switch t...

Page 9: ...ng plug are connected correctly insulation is provided properly and the rated voltage is realized Confirm items 1 to 3 above and then proceed to the item 4 AT Turn ON the MAIN POWER switch and confirm...

Page 10: ...nd confirm that the power indicator lamp lights Starts the dust collector AT ON Press the ON switch to start the operation 7 Choose operation ability in seven levels Push Lo switch or Hi switch in AT...

Page 11: ...panel and cause The wire 7 yellow is put inside a shrinkable tube so that it cannot be short circuited with other wires Remote operation switch ON Shifting to remote mode Remote control is possible in...

Page 12: ...ion The AT panel is disabled while the wires 4 and 8 are short circuited Yellow white Black White Operation pressure signal Output signals Transfers the current operation output Analog signal 0 5V Imp...

Page 13: ...Copyright CHIKO AIRTEC CO LTD 2009 13...

Page 14: ...in body Transfer required output signals in accordance with the explanation in 5 3 Color and signal of each wire AT ON Lo Hi Change with Lo Hi switch pushing the ON switch of main body AT panel when y...

Page 15: ...fore starting inspection Using a worn or damaged filter will release sucked dust to the atmosphere and damage electrical parts Make sure to inspect and maintain to prevent failures and accidents in th...

Page 16: ...make sure to attach it vertically If the nipple is inserted diagonally the clogging indicator lamp may malfunction and turn ON 1 Release the snap locks of the filter case and remove the primary filter...

Page 17: ...ds generated Is the installation level correct Filter installation status Once month Are the filters installed securely Filter clogged status Suction force check During operation Does the suction hose...

Page 18: ...verheated by clogged filters 3 30 After checking 1 to 3 above remove the cause of error and press the RESET switch Or turn OFF and ON the MAIN POWER switch to reset the error status Start the operatio...

Page 19: ...Copyright CHIKO AIRTEC CO LTD 2009 19 8 Indication of DANGER Labels SKV 250AT ACC SKV 450AT ACC V1...

Page 20: ...Copyright CHIKO AIRTEC CO LTD 2009 20 9 Electrical Circuit Diagram SKV 250AT ACC SKV 450AT ACC V1...

Page 21: ...7 2 35 58 70 62 5 1 dB Note The Noise column indicates a value dB on the scale A at 1 m on the main body side when the hose is connected to the suction port 11 Consumable Parts List Model 1 Primary f...

Page 22: ...ubject to change without prior notice Memo about purchase Model Manufacturer s serial number Date of purchase Start of operation Your name Address Phone Person in charge LTD 562 0012 1 1 33 1 1 33 Hak...

Reviews: