LAN control
Function
Command interface over TCP, port 60000.
HTTP server, port 80
Interface
Ethernet, RJ-45 connector
MAC address
SKD System AB MAC address space 00-50-C2C59XXX.
MAC address is printed on the product label.
MAC address can be read via Web interface or via app.
Defaults
Factory settings:
IP=192.168.1.222
GW=192.168.1.1
MASK=255.255.255.0
Command interface
Serial interface commands are listed in User Manual, product app and product web page.
USB control
Function
USB-host interface.
Charging of connected USB-devices.
Communication
Android Open Accessory Protocol 2.0 with extensions
Application
Control of the product by app in Android device.
Upgrade of firmware from USB-memory
Supported-devices
Android smart phones and tablets version 4.1 or higher
Interface
USB-A connector
Characteristics
Max charging current on USB interface 0.5A.
USB DC-supply leads are protected from overload by internal fuse of 2A DC.
Wieland mini male
Function
AC-connector for connection to mains
Type
Wieland, Gesis-mini, GST15i3, male
Characteristics
Rated 16A, color white
Wieland mini female
Function
AC-connector for connection of user equipment.
Type
Wieland, Gesis mini, GST15i3, female
Characteristics
Rated 16A, color white
Indirect WiFi control
Function
Communication via WiFi from Android device indirectly via LAN
Characteristics
Communication between the Android app and the product over WiFi starts automatically when app is
activated.
AutoFuse
Function
Software controlled fuse.
Complement to the 16A physical fuse integrated into the product.
AutoFuse disconnects power on both L and N lines, when current to the product exceeds a preset threshold
level (in Ampere) for the time period (in seconds) set by the fuse latency parameter.
AutoFuse is activated by command, via app or via product web page.
Mode of operation
When activated, AutoFuse turns AC switches off when current exceeds preset limit for the time set by
latency. AutoFuse get deactivated.
AC switch is not blocked when AutoFuse is inactive.
Control
Threshold level and latency of the AutoFuse can be set by command via LAN, via Android app or via product
Web page.
Defaults
Default current threshold level for automatic fuse is 16 Ampere and latency 3 seconds.
Product Approvals
Product safety
EN 60950-1:2006 +A1+A2+A11+A12