background image

RP-350.1D

RP-800.1D

RP-1500.1D

RP-2000.1D

RP-3500.1D

RP-4500.1D

RP-75.4AB

RP-150.4AB

RP-600.5

Summary of Contents for RP-150.4AB

Page 1: ...RP 350 1D RP 800 1D RP 1500 1D RP 2000 1D RP 3500 1D RP 4500 1D RP 75 4AB RP 150 4AB RP 600 5 ...

Page 2: ... 4ohm THD 4ohm Damping Factor Fuse Rating Dimensions L inches 6 30 W x 2 20 H inches RP 800 1D 370Watts x 1 600Watts x 1 800Watts x 1 1 ohm stable 6V 0 2V 50Hz 220Hz Off 50Hz 6dB 12dB 20 250Hz 85 Over 90 0 1 150 80A 10 13 inches RP 1500 1D 550Watts x 1 930Watts x 1 1500Watts x 1 1 ohm stable 6V 0 2V 50Hz 220Hz Off 50Hz 6dB 12dB 20 250Hz 85 Over 90 0 1 150 120A 13 267 inches All features are subjec...

Page 3: ...he products without notice DIGITAL MONOBLOCK FEATURES DIGITAL MONOBLOCK SPECIFICATIONS STABLE INTO 1 OHM LOAD HIGH SPEED MOSFET POWER SUPPLY 24dB OCT VARIABLE SUBSONIC FILTER 24dB OCT LOW PASS FILTER VARIABLE BASS EQ VARIABLE PHASE CONTROL 4 CHANNEL AMPLIFIER 5 CHANNEL AMPLIFIER CH1 CH4 STABLE INTO 2 OHM STEREO CH5 STABLE INTO 1 OHM 12dB OCT HIGH PASS FILTER FOR CH1 CH4 24DB OCT LOW PASS FILTER FO...

Page 4: ...ble 6V 0 2V 20Hz 5KHz 50Hz 500Hz na 6dB 12dB 20Hz 20KHz 105 Over 65 0 1 150 120A 17 72 inches RP 600 5 60Watts x 4 170Watts x 1 90Watts x 4 270Watts x 1 370Watts x 1 180Watts x 2 2 ohm for CH1 4 1 ohm for CH5 6V 0 2V 20Hz 5KHz CH1 2 CH3 4 50Hz 250Hz for CH5 10Hz 50Hz for CH5 0 12dB for CH5 20Hz 20KHz for CH1 4 20 250Hz for CH5 105 for CH1 4 85 for CH5 Over 65 for CH1 4 Over 90 for CH5 0 1 150 80A ...

Page 5: ...e sure to use fuses and fuse holder adequate for the application GND GROUND Locate a secure grounding connection as close to amplifier as possible Make sure the location is clean and provides a direct electrical connection to the frame of the vehicle The ground needs to have as low of a resistance as possible Connect one end of a short piece of the same size cable as the power cable to the groundi...

Page 6: ...DIGITAL MONOBLOCK SPEAKER CONNECTION 4 1 ohms 8 2 ohms 8 2 ohms ...

Page 7: ...ut slave switch to slave input Step 3 Connect RCA cable from the master to slave amplifier as shown in the diagram POWER SPEAKER CONNECTION Step 1 Connect speaker cable on master amplifier to subwoofer Step 2 Connect speaker cable on slave amplifier to subwoofer Step 3 Connect speaker cable on master amplifier to speaker cable on slave amplifier 12V SOURCE Fully adjusted signal is transferred from...

Page 8: ...MASTER AMPLIFIER SLAVE AMPLIFIER Remote turn on BATTERY 8 2 ohms Ground 2 ohm 12V SOURCE Remote turn on ...

Page 9: ...er Protect Remote Min Max 20Hz 5KHz 50Hz 500Hz Min Max 20Hz 5KHz 50Hz 500Hz HPF LP BP Full HPF LP BP Full 0dB 12dB 6dB 0dB 12dB 6dB 4 CHANNELS RCA INPUT CONNECTION HEADUNIT 4 CHANNELS SPEAKER CONNECTIONS POWER Bridged Bridged Ch2 Ch1 Ch4 Ch3 Mid Range Passive Tweeter ...

Page 10: ...5 CHANNEL RCA INPUT CONNECTION HEADUNIT POWER Bridged Bridged Ch2 Ch1 Ch4 Ch3 Mid Range Passive Tweeter 8 4 ohms ...

Page 11: ...5 CHANNEL SPEAKER CONNECTIONS 4 1 ohms 8 4 ohms 8 4 ohms Mid Range Passive Tweeter 4 1 ohms ...

Page 12: ...00 1D RP 2000 1D RP 3500 1D and RP 4500 1D RP 75 4AB and RP 150 4AB is 2 ohm stereo or 4 ohm mono RP 600 5 is 2 ohm stereo or 4 ohm mono for CH1 CH4 and 1 ohm for CH5 If amplifiers are shut down due to heat they will be on some minutes later after cooling down Please make better airflow and no obstruction around amplifiers for thermal protection RP 350 1D RP 800 1D RP 1500 1D RP 2000 1D RP 3500 1D...

Reviews: