1. FUNCTION DESCRIPTION 

This gynaecology examination table is for professional use in health care only, for 
examination of the patient. 

It is designed to be a functional and user-friendly tool for the operator and patient. 

 Note that the product must only be used by competent health 

professionals who read the user manual, for correct handling. 

 

General description 

Gynaecology table with electric adjustment of height, backrest and 
seat/Trendelenburg. All-welded powder coated steel chassis. Pads covered in 
artificial leather. 

Legrests on a ball-joint and integral foam mounted onto rails placed alongside the 
seat, onto which also accessories such as examination light may be attached.  

100 mm central locking castors. 
 

 

 

Summary of Contents for 016-5000

Page 1: ...200320 USER MANUAL GYNAECOLOGY EXAMINATION COLUMN TABLE Model 016 5000 NOTE The operator must read the user manual carefully BEFORE the product is used to avoid unnecessary risks to the patient and operator ...

Page 2: ...ckrest adjustment 2 5 Seat Trendelenburg adjustment 2 6 Paper roll holder 2 7 Castors 2 8 Battery backup 2 9 Leg plate 2 10 Patient handles 2 11 Legrests 2 12 Neck cushion 2 13 Knobs and handles 2 14 Seat pad and rinsing bowl 3 Maintenance and cleaning 3 1 Routine check ups 3 2 Cleaning 3 3 Accessories 3 4 Spareparts 4 Technical specification 4 1 Dimensions 4 2 Motors and control boxes 4 3 Battery...

Page 3: ...ied Therefore we reserve against possible changes in the user manual WARRANTY Sjöbloms provides a two year warranty for material design and manufacturing defects provided the products are not subjected to tampering or excessive wear For the guarantee to apply the product must have been used in accordance with the user manual and the maintenance performed as specified IMPORTANT INFORMATION This pro...

Page 4: ...Note that the product must only be used by competent health professionals who read the user manual for correct handling General description Gynaecology table with electric adjustment of height backrest and seat Trendelenburg All welded powder coated steel chassis Pads covered in artificial leather Legrests on a ball joint and integral foam mounted onto rails placed alongside the seat onto which al...

Page 5: ...g should be connected to a grounded outlet The product is now ready for use 2 2 Height adjustments Hand control Foot control Ensure that no unauthorized persons are in the couch s working range Follow the symbols and arrows to regulate the chair On the hand control height is adjusted via button line 2 ...

Page 6: ...e patient sits down We recommend that the staff helps the patient down especially elderly and younger patients so that they sit correctly 1 2 Lock the castors before the patient is seated The patient is to be seated mid seat leaning backwards against the backrest Max load 165 kg ...

Page 7: ...Gyn column table Operation SJÖBLOMS 46 660 84251 info sjobloms com Leg plate NOTE It is NOT allowed to sit on the pulled out leg plate The leg plate only intended for temporary resting of the legs ...

Page 8: ... 84251 info sjobloms com 2 4 Backrest adjustment Hand control Foot control Ensure that no unauthorized persons are in the couch s working range Follow the symbols and arrows to regulate the chair On the hand control height is adjusted via button line 2 ...

Page 9: ...ight is adjusted via button line 2 Button line 4 on the hand control plus one of the foot controls activates Treatment and Start position When the patient is seated and this function is activated the patient is gently transported backwards for 5 seconds after which the height angle backrest is adjuste simultaneously to the desired position Button line 5 activates Trendelenburg Left button lowers t...

Page 10: ...BLOMS 46 660 84251 info sjobloms com 2 6 Paper roll holder 1 Pull out the lock 2 Turn the lock upwards 3 Remove the steel from the hole on the oposite side and place the roll onto it 4 Place the steel in the left hole and set the lock to its original ...

Page 11: ...s SJÖBLOMS 46 660 84251 info sjobloms com 2 7 Castors Central locking castors are included 2 8 Battery backup With the optional battery backup you can run the chair if the power is cut Connects to the back of the chair Unlocked Locked ...

Page 12: ...plate towards you so that the front is raised When pulled out completely lift carefully The lock is then activated and the leg plate is in its place DONE To push it into place again pull the lock and press the leg plate forward so that it folds Press the leg plate in under the seat DONE NOTE The leg plate is only a support for resting the legs temporarily never to be used for sitting Damages due t...

Page 13: ...ory rail arrow and also be completely removed from the rail when necessary 2 11 The part onto which the leg rests is made of integral foam and may be adjusted variously via a ball joint The leg rest may also be adjusted up and down and along the rail forward backwards Note that the attachment that the legrest steel is placed into is of left and right hand side design If mounted on the wrong side t...

Page 14: ...or towards yourself applies to handle B then the tension mode is opened and you can turn back the handle without the achieved tension being released When you then release the handle it returns to the operational mode and you can repeat your hold 2 14 Seat pad rinsing bowl The seat pad and bowl may be removed for cleaning Seat pad Pull out the lock lift the seat plate remove and clean When re mount...

Page 15: ...echanism On electric tables Damages to electric cables The motor functions That joints and fittings are lubricated according to the lubrication chart 3 2 Cleaning Cleaning and disinfection of imitation leather During normal cleaning warm water and a mild soap solution should be used For full list specification ask us for the manufacturer s pdf Chlorine Chlorine based solutions are not recommended ...

Page 16: ...4251 info sjobloms com 3 3 Accessories Art nr Item 010 5000 70 Battery backup 3 4 Spare parts Art nr Item BL141HA11324B M Lifting column CB6S654 X2009 Control box CB06 J01297 Hand control 2362102000100G4 Motor leg plate J15591 Motor Trendelenburg J09980 Motor backrest 00771985 Castor ...

Page 17: ...ions Length 134 cm Length including legplate 174 cm Width 55 cm Seat height 55 95 cm Max height at leg plate rim when extended and the seat angle is max out 115 cm Backrest length 92 cm Backrest angle 10 60 Seat plate length 39 cm Leg plate length x width 31x44 cm Trendelenburg angle 22 Weight 97 kg Lift capacity 165 kg ...

Page 18: ... comply with EMC directives in accordance with standard EN 60601 1 2 At full load the motors can be used a maximum of 6 minutes hour The actuator manufacturer guarantees at least 10 000 cycles performance Control units Max usage time 10 or 6 min h at continuous operation Complies with directives in accordance with standard EN 60601 1 ...

Page 19: ...ally lose its stored energy It is therefore recommended that the batteries are recharged at least 8 hours before usage Battery life Battery life depends on several factors including the extent of discharging If the battery is discharged too extensively between charges the lifespan will be reduced Charging as often as possible is recommended The built in buzzer Charge the battery that is built into...

Page 20: ...ical specifications Labels SJÖBLOMS 46 660 84251 info sjobloms com 4 4 Labels The CE label contains the date order number serial number and our contact information Max patient weight 165 kg Shows not to sit on the leg plate ...

Page 21: ...ination table electric Art nr 016 5000 Product registration number 197141 Manufacturer Sjöbloms Sjukvårdsutrustning AB Myrängsvägen 8 S 891 50 ÖRNSKÖLDSVIK SWEDEN Sjöbloms Sjukvårdsutrustning AB ensures that the above products are in accordance with the EU Council MDD 93 42 EEC as well as the Swedish legislation in force 1993 584 on medical devices and the regulations issued by Medical Products Ag...

Page 22: ...le Contact info SJÖBLOMS 46 660 84251 info sjobloms com 6 CONTACT INFORMATION SJÖBLOMS Myrängsvägen 8 891 50 Örnsköldsvik Sweden Tel 46 660 105 80 Fax 46 660 180 00 E mail info sjobloms com Web page www sjobloms com ...

Reviews: