SJÖBLOMS 010-8251 User Manual Download Page 10

 

Ultrasound table 

Operation 

 

 

Cut-out section 

SJÖBLOMS 

+46 660 10580 

[email protected] 

2.7 Cut-out pad section 

 

 

 

 

 

 

Pull out the pad section.

 

 

NOTE!

 

Don’t leave the section 
hanging, risk of pinching.

 

Summary of Contents for 010-8251

Page 1: ...er 200320 USER MANUAL ULTRASOUND TABLE For models 010 8251 011 8251 NOTE The operator must read the user manual carefully BEFORE the product is used to avoid unnecessary risks to the patient and operator ...

Page 2: ...endelenburg position 2 5 Replacing the paper roll 2 6 Paper dispenser 2 7 The function of the castors 2 8 Cut out pad section 3 Maintenance Cleaning 3 1 Routine check ups 3 2 Cleaning 3 3 Lubrication scheme 3 4 Spare parts hydraulic 3 5 Spare parts electric 3 6 Accessories 3 7 Solutions for lubrication cleaning and disinfecting 4 Technical specification 4 1 Dimensions 4 2 Motors and control units ...

Page 3: ...ed Therefore we reserve against possible changes in the user manual WARRANTY Sjöbloms provides a two year warranty for material design and manufacturing defects provided the products are not subjected to tampering or excessive wear For the guarantee to apply the product must have been used in accordance with the user manual and the maintenance performed as specified IMPORTANT INFORMATION This prod...

Page 4: ...h professionals who read the user manual for correct handling General description 2 sectioned ultrasound table electrically or hydraulically adjustable chromium plated or coated all welded steel tube chassis Backrest and Trendelenburg adjusted by gas spring The cushions are stuffed with foamed plastic and upholstered with imitation leather The cut out section is adjusted manually 125mm swivel cast...

Page 5: ...lic To raise the product Pump the longer part of the pedal to raise the chassis to the desired height To lower the product Press the shorter part of the pedal to lower the chassis to a desired height Electric foot controll optional NOTE Ensure that no unauthorized persons are in the couch s working range as a pinch hazard exists when raising and lowering the product Follow the symbols and arrows t...

Page 6: ...hing down the backrest Electric foot control For exam table with two motors The right pair regulates the backrest The left pair regulates the height of the table For exam table with three motors The right pair regulates the backrest and or the Trendelenburg position Press the middle switch to change between the two functions The left pair regulates the height of the table NOTE Ensure that no unaut...

Page 7: ...en raising and lowering the product Gas spring To raise the Trendelenburg position stand at the foot end side of the table Press one of or both the handles The gas spring helps adjust the tables Trendelenburg function To lower the Trendelenburg position press the handle again while pressing down the table top Electric foot control optional The right pair regulates the backrest and or the Trendelen...

Page 8: ...Push the metal rod to the left C Pull the rod gently towards you until it comes loose on the right side D Pull the rod gently to the right The rod is now loose and you can put on a new paper roll E Put the rod back on the left side F Put the rod back on the right side in the score G Push the rod to the right H Screw the ball tight again The pair of attachments is mounted onto two square tubes unde...

Page 9: ... helps transporting the chassis straight in long corridors Central locking castors Separately locking castors Free castors Directional locking mode Braked mode Unbraked mode Central locking castor Free mode When the directional lock is activated it is important to have the castor locked as shown to the right the arrow shows a forward transportation direction Wrongly positioned the exam table trans...

Page 10: ...Ultrasound table Operation Cut out section SJÖBLOMS 46 660 10580 info sjobloms com 2 7 Cut out pad section Pull out the pad section NOTE Don t leave the section hanging risk of pinching ...

Page 11: ...Ultrasound table Operation Cut out section SJÖBLOMS 46 660 10580 info sjobloms com Fold the pad all the way around as shown Make sure the pin is inserted in the hole as shown Done ...

Page 12: ...tric tables Damages to electric cables The motor functions That joints and fittings are lubricated according to the lubrication chart 3 2 Cleaning Cleaning of imitation leather During normal cleaning warm water and a mild soap solution should be used or our own Cleaning solution for artificial leather art no R 1 Stronger cleaning agents should be avoided whenever possible If it nonetheless becomes...

Page 13: ...tion Lubrication according to the scheme should be performed every 6 months or as needed 1 First lock the castors 2 Enlist the help of another person and tip the couch on the side in order to lubricate the moving joints The spray can in the pictures above indicates where to lubricate HYDRAULIC ELECTRIC ...

Page 14: ...lic No Art no Article 1 2 G0001 Gas spring 3 010 8540 Paper roll holder including ball 4 12532142120LPZ Castor standard 4a 12532142122LPZ Castor braked 5 12532142123LPZ Castor directional locked 6 125321630T2LPZ Castor central locking 6a 125321630T3LPZ Castor central locking directional locking 7 HY001 Hydraulic pump 1 1 2 ...

Page 15: ... Paper roll holder including ball 4 12532142120LPZ Castor standard 4a 12532142122LPZ Castor braked 5 12532142123LPZ Castor directional locked 6 125321630T2LPZ Castor central locked 6a 125321630T3LPZ Castor central locked directional locked 7 HB814500001 01 Hand control one motor Linak 8 HB824500004 11 Handkontroll två motorer Linak 9 HB834500003 11 Handkontroll tre motorer Linak 1 1 2 ...

Page 16: ... 16 No Art no Article 12 FS1001 Fotkontroll en motor Linak 13 FS2001 Fotkontroll två motorer Linak 14 FS3001 Fotkontroll tre motorer Linak 15 CB9140AE3 000F0 Styrenhet Linak nätfrånskiljare 16 314100 1115004E Lyftmotor Linak 17 312100 3115004C Ryggstödsmotor Linak 18 312100 1110004C Chocklägesmotor Linak 17 18 ...

Page 17: ...o sjobloms com 3 6 Accessories Central locking castors Back support Not in picture Battery backup for electric ultrasound tables only Electrically adjustable backrest for electric ultrasound tables only Electrically adjustable Trendelenburg for electric ultrasound tables only ...

Page 18: ...ion and cleaning SJÖBLOMS 46 660 10580 info sjobloms com 3 7 Solutions for lubrication and cleaning R 1 Artificial leather cleaning solution 5557001 Lubrication for medical furniture C068 Disinfection solution Lubrication Cleaning solution Disinfection solution ...

Page 19: ...mensions SJÖBLOMS 46 660 10580 info sjobloms com 4 TECHNICAL SPECIFICATION 4 1 Dimensions Length 200 cm Length backrest 75 cm Width 70 cm Weight 67 kg Height 53 91 cm Max patient weight 200 kg SWL 220 kg Angle backrest 71o Angle Trendelenburg 14o ...

Page 20: ...tors comply with EMC directives in accordance with standard EN 60601 1 2 At full load the motors can be used a maximum of 6 minutes hour The actuator manufacturer guarantees at least 10 000 cycles performance Control units Max usage time 10 or 6 min h at continuous operation Complies with directives in accordance with standard EN 60601 1 ...

Page 21: ... lose its stored energy It is therefore recommended that the batteries are recharged at least 8 hours before usage Battery life Battery life depends on several factors including the extent of discharging If the battery is discharged too extensively between charges the lifespan will be reduced Charging as often as possible is recommended The built in buzzer Charge the battery that is built into the...

Page 22: ...bels The CE label contains the date order number serial number and our contact information Max patient weight 200 kg Displays the adjustment of the backrest There is a label on each side of the table Displays the adjustment of the Trendelenburg position There is a label on each side of the table ...

Page 23: ...t registration number 13958 Model 011 8251 Product registration number 13949 The appendix contains documents that have been applied for verification of compliance Manufacturer Sjöbloms Medical Equipment AB Myrängsvägen 8 S 891 50 ÖRNSKÖLDSVIK SWEDEN Sjöbloms Sjukvårdsutrustning AB ensures that the above products are in accordance with the EU Council MDD 93 42 EEC as well as the Swedish legislation...

Page 24: ...le Contact info SJÖBLOMS 46 660 10580 info sjobloms com 6 CONTACT INFORMATION SJÖBLOMS Myrängsvägen 8 891 50 Örnsköldsvik Sweden Tel 46 660 105 80 Fax 46 660 180 00 E mail info sjobloms com Web page www sjobloms com ...