Power wires with Grounding gets into the terminal blocks located right bottom of the
unit. A set of 10AWG/2 wires with Grounding wire should run from a 30A double pole
breaker on the home main breaker panel, to the water heater unit terminal blocks.
Securely tightened to get 240V supply.
The unit should be installed vertically on a flat surface that is larger than the unit itself.
Drill 4 holes into the wall for mounting screws,in accordance with the installation
template.Make sure the unit is securely mounted by those 4 wall anchor and screws
provided. Keep the unit away from any slashing or leaking water, also strong magnetic
field.