The CTS-9006/ CTS-9009 digital ultrasonic flaw detector is the perfect combination of various 

advanced modern technologies such as ultrasonic flaw detection, computer, electronics, mould, 

techniques. Therefore we present a series of digital ultrasonic flaw detectors with higher 

performance and more powerful functions to the industry.   

Main features of the CTS-9006/ CTS-9009 digital ultrasonic flaw detector: 

1

 Small size —— The dimension of the whole unit is 152mm

×

240mm

×

52mm (W

×

H

×

D). This is the 

smallest size among all flaw detectors with a 5.7-inch monitor.   

2

 Light weight —— The total weight of the unit (including battery) is 1.15kg only.   

3

 Low consumption —— Given that the system has small size and light weight, a fully-recharged 

battery can support the system to work continuously over 7 hours.   

4

 High performance ——The main technical specifications, such as detection sensitivity surplus, 

vertical linearity, horizontal linearity and dynamic range, are much better than the requirements 

of China’s national standard.   

5

 Rich functions —— The system is featured with USB port, auto gain control, peak memory, DAC, 

AVG. Moreover, the CTS-9009 has many additional functions, such as network communication, 

probe frequency measure, cine, curved surface correction and AWS code.   

6

 Easy operation —— The user-friendly system interface is quite intuitive with just a few buttons 

for easy definition and simple operation.   

 

This Operation Manual contains the following chapters:   

Chapter 1 gives a brief introduction to the system.   

Chapter 2 describes system menus and functional operation.   

Chapter 3 describes some operation techniques, so as to facilitate the users to operate the system 

quickly and conveniently.   

Chapter 4 describes the general steps when performing field testing with the system, and gives 

some application examples. 

Chapter 5 describes how to use peripheral devices, ports and accessories.   

Summary of Contents for CTS-9006

Page 1: ...CTS 9006 CTS 9009 Digital Ultrasonic Flaw Detector Operation Manual Shantou Institute of Ultrasonic Instruments Co Ltd...

Page 2: ......

Page 3: ...S D1 1 D1 5 welding code Optional API 5UE Defect Sizing Quantitative Criteria Curved Surface Correction Crack Height Sizing Echo Magnifier within gate Amplitude B Scan Special Thickness Measurement Mo...

Page 4: ......

Page 5: ...ION 9 2 1 POWER SUPPLY 9 2 2 POWER ON 9 2 3 POWER OFF 9 2 4 MAIN MENU SELECTION 10 2 5 SUBMENU SELECTION 10 2 6 TURNING PAGE 10 2 7 GENERAL SUBMENU ADJUSTMENT 10 2 8 EXTENDED SUBMENU 11 2 9 SELF DEFIN...

Page 6: ...10 APPLYING PEAKECHO TO MAKE DAC CURVES 31 3 11 USING DIFFERENT COLORS TO ACHIEVE OPTIMAL VISUAL EFFECT IN APPLICATION 31 3 12 IMPACT OF GATE STATE ON GATE MEASUREMENT RESULTS 32 CHAPTER 4 TESTING AP...

Page 7: ...INCORRECT HORIZONTAL READING WHEN USING AN ANGLE PROBE 49 APPENDIX B SPECIFICATIONS 51 APPENDIX C SUBMENU DEFAULT VALUE AND RANGE OR OPTION 55 APPENDIX D ADDITIONAL DATA ON CTS 9009 59 D 1 APPEARANCE...

Page 8: ......

Page 9: ...nce The main technical specifications such as detection sensitivity surplus vertical linearity horizontal linearity and dynamic range are much better than the requirements of China s national standard...

Page 10: ...leshoot the problems Appendix B describes system main performance specifications Appendix C describes system submenus Appendix D describes differences between CTS 9009 and CTS 9006 and their correspon...

Page 11: ...described in the Operation Manual 4 The system warranty will be void if the fragile labels on specific positions are damaged 5 Do not place the system in the place of moisture or near radiator strong...

Page 12: ......

Page 13: ...gital ultrasonic flaw detector especially suitable for 1 Material testing flaw positioning and echo evaluation 2 Thickness measurement 3 Testing result storage and recording 4 General ultrasonic testi...

Page 14: ...Shantou Institute of Ultrasonic Instruments Co Ltd 2 Fig 1 2 System Back View Fig 1 3 System Side View Handle Battery Battery securing screw Probe Socket R Probe Socket T...

Page 15: ...ing Buzzer Port The buzzer sound outlet when the alarm sound is enabled USB Port To connect a USB disk or a printer DC Power In Socket For main unit power supply when connected to the external charger...

Page 16: ...C Function To activate cancel AGC function Confirm To execute a function or confirm an item B Ba as si ic c To adjust system basic parameters including Range Velocity Delay Zero Reject Gain Step Gate...

Page 17: ...AC Table 1 3 Menu Structure Continued Main Menu Submenu Main Menu Submenu Submenu Submenu StandardName Angle PRF Fill_Mode Grade K_Value MeasPt Unit X_Value Horn Lang Thk Coor Date Power AVG_Freq Time...

Page 18: ...e 1 The item in bold font indicates that this submenu has extended submenu If selected the extended submenu will show up Note 2 The submenu marked with has coarse adjustment fine adjustment The submen...

Page 19: ...le 1 4 Description of Parameters and Symbols Parameter Symbol Description a Echo measurement point sound path within gate a a Echo measurement point depth within gate a when testing with an angle prob...

Page 20: ...only EW The flat bottomed hole equivalent of echo measurement point within gate under AVG curve display under AVG curve only Rs Range start Re Range end 1 2 3 4 This coordinate reading corresponds to...

Reviews: