Technical Specifications
16
www.sitron.com - email: [email protected]
CF12AC
Repeatability
Application
Operating Voltage
Current Consumption
Electrical Connection
Operating Temperature
Gradient Temperature
Set Point Range
Output
Flow Rate Indication
Max Pressure
Accuracy
Response Time
Enclosure Material
Wetted Material
Class Protection
Process Connection
+/- 10%
1 to 10s
15ºC/min
Liquid: 3 cm/s to 3 m/s - Gas: 5 cm/s to 5 m/s
+/- 1% setpoint
Cable gland w/ 2000mm cable, M12 connector or ½” NPT
Red led - flow is below setpoint
Yellow led - flow is at setpoint
Green led - flow is above setpoint
1450 PSI (100 Bar)
IP65 (IEC 60529)
NEMA 4X (G1 / G2 )
Glass filled nylon (option - Aluminium)
316 Stainless Steel
½” to 1 1/2” BSP or NPT, adjustable, sanitary or flanged connections
14 to 176º F (-10 to 80ºC) sanitary option to 248ºF (120ºC)
Flow for liquids and gas level for liquids only
85-240Vac (50/60hz) & 125Vdc
+/- 100mA
Relay(SPDT) 5A - 250Vac (1 SPDT N1/G1/G3)
(2 SPDT - G2 or GX) aluminum enclosure
85...260 Vac 50/60 Hz
Adjust
Pin# 1/2 Power
Pin# 3 Ground
Pin# 4 N.O.
Pin# 5 N.C.
Pin# 6 Neutral
-Detect
-Switch
-Flow
CF12AC
N1 Enclosure
G2 Enclosure
G1 Enclosure
G3 Enclosure
Adjust
Flow
100 %
0
+
-
1 2 3
4
5 6
7
9
8
+
_
1
2
3
4
5
6
Adjust