Installation 
This gas detector must be installed by a competent person. 
The gas installation and shut-off device (where used) must comply with 

the appropriate national regulations. 

Electricity must be turned off before beginning installation to prevent 

electrical shock or equipment damage. 

Connect the output signal wire with the solenoid valve. (If applicable, 

please refer to next section) 

Having established the mounting location ensures that there is no electrical 

wiring or pipe work in the area next to the mounting surface. 

Mark the proper location on the wall according to the two holes of the 

bracket of alarm. (Refer to diagram 3) 

Drill two 

ф

5.0mm holes in the wall, then insert the plastic plugs into the 

holes.Attach the bracket to the plastic plugs and fix tightly the screws into the 
plastic plugs.Fit the alarm on the bracket and pull it down until matching well 
on the bracket. 

Insert the power plug into the socket after installation, the power light will 

be on. the gas detector will be in self- detection for about 3 minutes. During this 
period, green LED is flashing.When it stops,the green LED is constant on, and 
the detector is ready for use.

 

 

Additionally, any changes to the gas installation, e.g., fitting of an 

automatic gas shut-off valve, must be carried out by a person qualified to the 
national regulations for gas installations. 

Note for installation of solenoid valve: 
To prevent the possibility of death, serious injury or property damage, 

close the electricity and gas supply pipeline before installation. 

Removing impurities like metal powder and rust from the pipeline. 
Ensure the solenoid valve is horizontal, i.e., the input and output port of 

solenoid valve must keep on the horizontal level. 

The solenoid valve can’t mount reversely, while there is a mark for gas 

flow direction on the valve. (Refer to diagram 4) 

External leakage tests must be carried out after installation. 
Have any problem caused by solenoid valve, please call our agent. 

 

Diagram 3 

 

Diagram 4 

Manufacturer: 

SITERWELL ELECTRONICS CO., LIMITED

 

ADDRESS: No.666 Qingfeng Road, Jiangbei District, Ningbo, Zhejiang Province, 

China 

TEL: 0086-574-87729581 

FAX: 0086-574-87729581 

E-MAIL: [email protected]   

URL: www.china-siter.com 

Summary of Contents for GS869

Page 1: ...d valve Solenoid valve Specifications If applicable Control type Normally open Actuation voltage DC 9V pulse voltage Temperature 10 60 Reset style manual reset Maximum pressure 50Kpa Flux 25m3 h Connection style screw thread Status All statuses of the detector are showed in the summary table Summary Table Status Illustration Green LED Yellow LED Red LED Horn Solenoid valve Self Test Power on ON ON...

Page 2: ...ly may be reinstated and the solenoid valve must be manual reset Even if the apparatus is fitted with a triggering device for example for closing a solenoid valve on the incoming gas pipe the same procedure as described above should be followed The detector should not be installed directly above cooking appliances in any outside location in an enclosed space e g in a cupboard or behind a curtain d...

Page 3: ...hlorine gas Hydrogen chloride alkaline metals water alcohol based products propane isobutene isopropanol ethylene benzene toluene ethyl acetate paints thinner solvents adhesives hair sprays after shaves perfumes and some cleaning agents etc Warning If water freezes on the sensing surface the sensing material would crack altering characteristics Warning The detector cannot properly operate in a zer...

Page 4: ...r will be in self detection for about 3 minutes During this period green LED is flashing When it stops the green LED is constant on and the detector is ready for use Additionally any changes to the gas installation e g fitting of an automatic gas shut off valve must be carried out by a person qualified to the national regulations for gas installations Note for installation of solenoid valve To pre...

Reviews: