4
/
8
always on about 5 seconds, else the yellow led always on 5 seconds.
Note: Exclusion network status, you can click on the button to exit.
Note: If the alarm is remove(excluded), then the sensor will be itself restored to factory default settings.
4: Factory Default Reset
It happens automatically when the device is excluded or you can use the following steps to reset factory settings.
a: Remove the battery.
b: Press the button and don't let go. And then connecting the battery, the red led will on 3 seconds,3 seconds later, when the red light is off,
then release the button.
c. When the button is released, the red light is lit for 3 seconds. In these 3 seconds, press the button, then the red led will flash quickly about
10 seconds (
NOTE: Do not turn off the power when the red led flashes
). After successful recovery factory settings, the product into
preheating state.
Note: If this sensor is reset, the information of Z-Wave network in the sensor will be deleted. The sensor
will be itself restored to factory default settings. Please use this procedure only when the network
primary controller is missing or otherwise inoperable.
NOTE: Damage to the Z-Wave module will not affect the main function of the alarm, only affect the
module related functions.
Associations
When networking with the product host
,
this feature is used to associate other products. This has the effect that when the sensor detects
the CO leak, all devices associated with the sensor will receive the relevant reports and can be controlled by the sensor, e.g. the CO value,
alarm device etc.
This device supports three linkage groups:
The group 1 is the lifeline group.
Linkage group 2 is assigned to the devices status - sending BASIC SET control frame to the associated devices having detected the CO
leak.
Linkage group 3 reports the detection's status to the associated device.
The maximum number of devices that can be added to the linkage
group 1 is 5
number
,
linkagegroup2 or linkage group3 is 5 numbers.
This product will send a “BASIC SET(0xFF)” message to associated group, when press and release the test button(<2s) to check the
function; and this CO alarm will also send a “BASIC SET(0x00)” message to associated group, after end of test alarm(<10s). This CO alarm
will send a “BASIC SET(0xFF)” message to associated group, when this product is CO alarm (
Conforms to EN 50291-1:2010+A1:2012
standard
); and this product will also send a “BASIC SET(0x00)” message to associated group, when CO alarm is cleared.
Installation instructions
WARNING
:
This alarm should be installed by a competent person.
WARNING: Installation of the alarm should not be used as a substitute for proper installation, use and maintenance of fuel burning
appliances including appropriate ventilation and exhaust systems.
1: Installation location
When choosing your installation locations, make sure you can hear the alarm from all sleeping areas. If you install only one CO alarm in
your home, install the alarm near bedrooms. Not in the basement or furnace room. The recommended position for the unit should be at least
1.8 meters (about 6 feet) above the floor level. Far away metal installation.
2: Mounting step
a: Drilling two
ф5.0
mm holes in the wall, the distance between two holes center is 30mm
(
1.18 inch
)
,then inserting two plastic stopper
provided into the holes.
b: Insert the two screws provided until the screw heads are approximately 5mm from wall.
c: Test the unit by using the TEST&SILENCE button. Ensure the unit sound is alarm pattern.
d: Hook the unit over the screws onto keyholes in back of unit.