Siterwell GS816B Instruction Manual Download Page 4

 

 

4

 / 

8

 

 

always on about 5 seconds, else the yellow led always on 5 seconds.   

Note: Exclusion network status, you can click on the button to exit. 

Note: If the alarm is remove(excluded), then the sensor will be itself restored to factory default settings. 

4: Factory Default Reset

 

It happens automatically when the device is excluded or you can use the following steps to reset factory settings. 

a: Remove the battery.   

b: Press the button and don't let go. And then connecting the battery, the red led will on 3 seconds,3 seconds later, when the red light is off, 

then release the button. 

c. When the button is released, the red light is lit for 3 seconds. In these 3 seconds, press the button, then the red led will flash quickly about 

10 seconds (

NOTE: Do not turn off the power when the red led flashes

). After successful recovery factory settings, the product into 

preheating state.   

Note: If this sensor is reset, the information of Z-Wave network in the sensor will be deleted. The sensor 

will be itself restored to factory default settings. Please use this procedure only when the network 

primary controller is missing or otherwise inoperable. 

NOTE: Damage to the Z-Wave module will not affect the main function of the alarm, only affect the 

module related functions.

 

Associations

 

When networking with the product host

this feature is used to associate other products. This has the effect that when the sensor detects 

the CO leak, all devices associated with the sensor will receive the relevant reports and can be controlled by the sensor, e.g. the CO value, 

alarm device etc. 

This device supports three linkage groups: 

The group 1 is the lifeline group.

 

Linkage group 2 is assigned to the devices status - sending BASIC SET control frame to the associated devices having detected the CO 

leak. 

Linkage group 3 reports the detection's status to the associated device.   

The maximum number of devices that can be added to the linkage 

group 1 is 5 

number

linkagegroup2 or linkage group3 is 5 numbers. 

This product  will send a “BASIC SET(0xFF)” message to associated group, when press  and release the test  button(<2s) to check the 

function; and this CO alarm will also send a “BASIC SET(0x00)” message to associated group, after end of test alarm(<10s). This CO alarm 

will send a “BASIC SET(0xFF)”  message to  associated group, when this product  is CO  alarm  (

Conforms to EN 50291-1:2010+A1:2012 

standard

); and this product will also send a “BASIC SET(0x00)” message to associated group, when CO alarm is cleared. 

Installation instructions 

WARNING

This alarm should be installed by a competent person. 

WARNING: Installation of the alarm should not be used as a substitute for proper installation, use and maintenance of fuel burning 

appliances including appropriate ventilation and exhaust systems.

 

1: Installation location 

When choosing your installation locations, make sure you can hear the alarm from all sleeping areas. If you install only one CO alarm in 

your home, install the alarm near bedrooms. Not in the basement or furnace room. The recommended position for the unit should be at least 

1.8 meters (about 6 feet) above the floor level. Far away metal installation.   

2: Mounting step 

a: Drilling two 

ф5.0

mm holes in the wall, the distance between two holes center is 30mm

1.18 inch

,then inserting two plastic stopper 

provided into the holes. 

b: Insert the two screws provided until the screw heads are approximately 5mm from wall. 

c: Test the unit by using the TEST&SILENCE button. Ensure the unit sound is alarm pattern. 

d: Hook the unit over the screws onto keyholes in back of unit. 

Summary of Contents for GS816B

Page 1: ...ction Manual CARBON MONOXIDE ALARM Thank you for your support Please read the instruction manual carefully before operating Please keep the instruction manual for future reference SITERWELL ELECTRONICS CO LIMITED ...

Page 2: ...S816B Type of apparatus Type A Power Supply DC 3V 2pcs alkaline battery Recommend battery type GP GN15A Raymax LR6 Sensor Type Electrochemical Product life 10 years after initial power up Sensitivity Setting Conforms to EN 50291 1 2010 A1 2012 standard 30PPM Without alarm before 120 minutes 50PPM Between 60 to 90 minutes 100PPM Between 10 to 40 minutes 300PPM Less than 3 minutes Standby Current 50...

Page 3: ...COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_MANUFACTURER_SPECIFIC COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_BATTERY COMMAND_CLASS_NOTIFICATION COMMAND_CLASS_WAKE_UP COMMAND_CLASS_SUPERVISION Supported Notification Type CO Alarm 0x02 CO Alarm Supported Event a Carbon monoxide detected Unknown Location 0x02 b Carbon monoxide Test 0x03 c Replacement Required Unspe...

Page 4: ...he devices status sending BASIC SET control frame to the associated devices having detected the CO leak Linkage group 3 reports the detection s status to the associated device The maximum number of devices that can be added to the linkage group 1 is 5 number linkagegroup2 or linkage group3 is 5 numbers This product will send a BASIC SET 0xFF message to associated group when press and release the t...

Page 5: ...damp and humid areas such as the bath room Avoid spraying aerosols near the CO alarm Do not install in areas where the temperature is below 10 or hotter than 40 Do not place behind curtains or furniture CO must be able to reach the sensor for the unit to accurately detect CO Do not place near metal objects otherwise it will affect the distance of wireless signal transmission Tips 1 Start up After ...

Page 6: ...FAULT indicator yellow LED flashing twice every 30 seconds indicates that the battery is low battery you must to replace the battery with battery specified To install or replace the battery in unit please perform the following steps 1 Take down the unit from screw heads of the wall 2 Open battery compartment 3 Remove the old battery and replaced by new battery 4 Close battery compartment 5 Hook th...

Page 7: ...s a colourless odourless non irritating gas classified as a chemical asphyxiant and whose toxic action is a direct result of the hypoxia produced by a given exposure CO is rapidly absorbed through the lungs diffuses across the alveolar capillary membrane and is reversibly bound with haemoglobin as carboxyhaemoglobin COHb however a minute amount is present in the plasma The affinity of haemoglobin ...

Page 8: ...us will not fully safeguard individuals at special risk Manufacturer and Service information SITERWELL ELECTRONICS CO LIMITED ADDRESS NO 76 HAICHUAN ROAD CHUANGYE ZONE B JIANGBEI NINGBO CHINA TEL 0086 0574 87729581 FAX 0086 0574 87729581 E MAIL Sales china siter com Guarantee THREE YEARS LIMITED WARRANTY Dear customer Our products are subject to strict quality controls However if this device shoul...