6
–
Replacing batteries (see
diagram 1
):
1.
Turn the alarm body counterclockwise and take out the alarm body from the bracket.
2.
Take out the old batteries from the battery box.
3.
Fix the two new batteries to the battery box. Please note the polarity of the batteries.
4.
Fit the alarm body onto the bracket and turn the alarm body clockwise.
5.
Test the smoke alarm using the test button. The sound pattern is 3 short beeps - 1.5seconds pause, 3
short beeps -
4.5seconds pause and is then repeated. If there’s no sound output, it means that the smoke
alarm is faulty or the installing operation is wrong and you should gain the correct method of disposal
through reading “TROUBLE SHOOTING”
.
RECOMMENDED LOCATIONS FOR ALARMS:
Install the first alarm in the immediate area of the bedrooms. Try to monitor the exit path as the bed-
rooms are usually farthest from the exit. If more than one sleeping area exists, install additional alarms in
each sleeping area.
Install additional alarms to monitor any stairway as stairways act like chimneys for smoke and heat.
Install at least one alarm on every floor level and install an alarm in every bedroom. Install an alarm in
every room where someone sleeps with the door closed. The closed door may prevent an alarm not in-
stalled in that room from waking the sleeper.
Install alarms in every room where electrical appliances are operated (i.e. portable heaters or humidifi-
ers).
Smoke, heat and burning things will spread horizontally after rising to the ceiling. So install the alarm in
the middle of the ceiling of an ordinary structure house. Let the alarm induce every corner.
Not recommend to use for in
MOBILE HOMES
.
For single floor plan and multiple floor plan, please refer to
diagram 2
and
diagram 3
.
If alarm couldn’t be installed in the middle of the ceiling for some reasons, the distance
from the wall
corner should be at least 50 cm. (see
diagram 4
).
If the length of the room or the hall is beyond 30 feet (10m), you need to install several alarms in the hall.
When the ceiling is slanting, the alarm needs to be installed 500 mm (2 feet) away from the highest
ceiling point in the room (see
diagram 5
).
Installation Steps
Fix the two AA batteries to each battery box of the smoke alarm.
Ensure the wireless function is ok according to the section
“Wireless function description” o
n operating
the smoke alarm.
Press the bracket on the installation position and mark installation holes of bracket with pencil.
Note:
Make sure that there are
no cables under these positions
.
Drill two installation holes at the marks with an electric drill. Make holes with a diameter of 5 mm and a
depth of 30 mm. Strike the two plastic plugs into holes with hammer.
Attach the bracket to the plastic plugs and fix the screws tightly into the plastic plugs (see
diagram 6
).
·Fit the alarm on the bracket and turn the alarm body clockwise until matching well on the bracket.
Test smoke alarm using test button. The alarm will sound 3 short beeps
–
1.5 seconds pause and then
repeat it until the button is released.
If there is no sound this indicates to a defective alarm. Please refer to section
“Trouble shooting” for a
solution or return the device to your retailer during warranty.
If you have any questions on installation please contact your retailer.
During testing other smoke detectors may alarm. Once the button is released the other devices will stop
alarming in approx. 1 minute.
WARNING:
To prevent injury, this unit must be securely attached to the ceiling in accordance with the
installation instructions.