USE AND INST
ALLA
TION INSTRUCTIONS
INSTALLATION
When installation of this product begins…
1. Read all of these instructions carefully. Failure to follow these instructions could damage the
product or cause a dangerous condition.
2. Check the ratings given in the instructions and on the appliance to make certain that the control
is suitable for your application.
3. All operations of installation, calibration, conversion and regulation must be undertaken
exclusively by a qualified and certified Gas Appliance Service Technician following the
instruction specified in this catalog and those in the instruction manual of the appliance in which
the valve is installed.
4. After installation is complete, verify that the appliance is operating as indicated in these
instructions.
STOP
Do not install, replace, or in any way modify the gas valve or the appliance, unless
CERTIFIED and QUALIFIED as a Gas Appliance Service Technician on the appliance this
valve is used on. READ AND FOLLOW ALL INSTRUCTIONS.
CAPACITy
880- Power test gas A [Kbtu/h, d=0.64, Hi=37.3 Mj/m3]-Pinlet=3,5["w.c.]-d pil = 0.3mm
0
10
20
30
40
50
60
70
80
90
100
110
120
0
0.5
1
1.5
2
2.5
3
∆
P ["w.c.]
P
[k
bt
u/
h]
FLOW RATE Q AS A FUNCTION OF PRESSURE DROP ∆P
OPERATION
880 Proflame has two automatic shut-off valves. When both of them are de-energised, it is only
possible to measure the inlet pressure on the inlet pressure test point.
When the solenoid EV1 is energised the first gas valve opens. The pilot outlet is enabled.
Energising the second solenoid EV2, the second valve also opens and the gas flows through the
main outlet.
It is possible to measure the outlet pressure on the outlet pressure test point.
The servo pressure regulator diaphragm system allows improved performance of outlet pressure
regulation. The outlet pressure can be adjusted by a screw.
Summary of Contents for PROFLAME 880