background image

USE AND INST

ALLA

TION INSTRUCTIONS

INSTALLATION

When installation of this product begins…
1. Read all of these instructions carefully. Failure to follow these instructions could damage the
  product or cause a dangerous condition.
2. Check the ratings given in the instructions and on the appliance to make certain that the control
  is suitable for your application.
3.  All  operations  of  installation,  calibration,  conversion  and  regulation  must  be  undertaken
  exclusively  by  a  qualified  and  certified  Gas  Appliance  Service  Technician  following  the
  instruction specified in this catalog and those in the instruction manual of the appliance in which
  the valve is installed.
4.  After  installation  is  complete,  verify  that  the  appliance  is  operating  as  indicated  in  these
  instructions.

STOP

Do not install, replace, or in any way modify the gas valve or the appliance, unless 
CERTIFIED and QUALIFIED as a Gas Appliance Service Technician on the appliance this 
valve is used on. READ AND FOLLOW ALL INSTRUCTIONS.

CAPACITy

880- Power test gas A  [Kbtu/h, d=0.64, Hi=37.3 Mj/m3]-Pinlet=3,5["w.c.]-d pil = 0.3mm

0

10

20

30

40

50

60

70

80

90

100

110

120

0

0.5

1

1.5

2

2.5

3

P ["w.c.]

[k

bt

u/

h]

FLOW RATE Q AS A FUNCTION OF PRESSURE DROP ∆P

OPERATION

880 Proflame has two automatic shut-off valves. When both of them are de-energised, it is only 
possible to measure the inlet pressure on the inlet pressure test point.
When the solenoid EV1 is energised the first gas valve opens. The pilot outlet is enabled.
Energising the second solenoid EV2, the second valve also opens and the gas flows through the 
main outlet. 
It is possible to measure the outlet pressure on the outlet pressure test point.
The servo pressure regulator diaphragm system allows improved performance of outlet pressure 
regulation. The outlet pressure can be adjusted by a screw.

Summary of Contents for PROFLAME 880

Page 1: ...8 8 0 P R O F L A M E USE AND INSTALLATION INSTRUCTIONS Read the instructions before use This control must be installed in accordance with the rules in force 9 957 018 02 ...

Page 2: ...tor FLO is the outlet filter on request PA is the pilot adjustment screw FLP is the pilot filter GAS INLET FLI EV1 RP EV2 MAIN BURNER PILOT BURNER FLP FLO PA GAS INLET FLI EV1 RP EV2 MAIN BURNER PILOT BURNER FLP FLO PA Fig 1 880 schematic blocks TECHNICAL DATA Gas inlet and outlet connections 3 8 18 NPT ANSI B 1 20 1 Pilot outlet 7 16 24 UNS 2B ANSI Installation position Upright LTD horizontal Nev...

Page 3: ...let 8 Gas inlet with protective seal 9 Gas outlet with protective seal 10 Ground connection 11 Mounting dead holes 12 Mounting through holes VALVE DESCRIPTION Aluminium alloy body In line inlet and outlet Pilot outlet Inlet filter Inlet pressure test point Outlet pressure test point Two mounting through holes on the side Two mounting dead holes on the gas inlet and outlet MAIN FEATURES 1 2 10 6 8 ...

Page 4: ... in any way modify the gas valve or the appliance unless CERTIFIED and QUALIFIED as a Gas Appliance Service Technician on the appliance this valve is used on READ AND FOLLOW ALL INSTRUCTIONS capacity 880 Power test gas A Kbtu h d 0 64 Hi 37 3 Mj m3 Pinlet 3 5 w c d pil 0 3mm 0 10 20 30 40 50 60 70 80 90 100 110 120 0 0 5 1 1 5 2 2 5 3 P w c P kbtu h FLOW RATE Q AS A FUNCTION OF PRESSURE DROP P OPE...

Page 5: ...not remove the seals until ready for connection to piping Appliance manufacturer s instructions supercede any instructions listed in this instruction book WARNING DO NOT SUBJECT THE VALVE TO BENDING IN EXCESS OF 310 LBF IN AND TORQUE IN EXCESS OF 220 LBF IN General recommendations Do not tamper with sealed parts Do not slacken assembly screws Do not remove labels Avoid blows knocks falls etc Only ...

Page 6: ...quality pipe compound DO NOT USE TEFLON TAPE to the pipe only leaving two end threads bare On LP installations use compound that resists exposure to LP gas 4 Remove seals over inlet and outlets if necessary 5 Connect pipe to valve inlet and outlet Place a 1 1 16 wrench on valve as shown in Fig 3 6 Thread pipe into the valve until a gas tight seal is achieved Typically for NPT thread penetration is...

Page 7: ...rew and retest If after tightening the pressure test port screw and the leak is still present shut off main gas supply then replace the valve WARNING Fire or Explosion hazard Can cause damage to property and severe injury or death The appliance where this combination gas control is installed does not have a permanent pilot It is equipped with an ignition device which automatically light the burner...

Page 8: ......