PROFLAME 2 BA
TTER
Y HOLDER USE AND INST
ALLA
TION INSTRUCTIONS
Fig. 2: Wiring diagram.
FUNCTIONS
The Proflame 2 battery holder provides backup system power during line power interruption
through the installed 4 AA type batteries.
The Proflame 2 battery holder connects directly to the Proflame 2 integrated fireplace control (IFC)
board through the 0.584.920 and 0.584.922 wire harness, see Fig.2.
The Proflame 2 battery holder has a three position slider switch for system control. The slider switch
can be set to one of three positions:
OFF position
With the slider in OFF position, the system is "OFF". No function can be selected by the transmitter.
No "beep" will be emitted from the Proflame 2 IFC when a command is sent by pressing any key on
the transmitter (for example the ON / OFF key).
ON position
With the slider in ON position, the burner flame is "ON". Only the other functions ( Fan, Lights, etc.)
can be selected by the transmitter.
Remote position
With the slider in Remote position, all the functions can be selected by the transmitter.
Programming Button (PRG)
When pushed allows a transmitter to be accepted for use by the system. See "Initializing the
System for the first time"
0.584.920
0.584.922
CONNECT TO
IFC BOARD
X8 TERMINAL
CONNECT TO
IFC BOARD
X5 TERMINAL
CONNECT TO
BATTERY
HOLDER 6 PIN
TERMINAL
CONNECT TO
0.584.920
J1 TERMINAL
CONNECT TO
0.584.922
J1 TERMINAL