PROFLAME 2 BA

TTER

Y HOLDER USE AND INST

ALLA

TION INSTRUCTIONS

Fig. 2: Wiring diagram.

FUNCTIONS

The  Proflame  2  battery  holder  provides  backup  system  power  during  line  power  interruption 
through the installed 4 AA type batteries.
The Proflame 2 battery holder connects directly to the Proflame 2 integrated fireplace control (IFC) 
board through the 0.584.920 and 0.584.922 wire harness, see Fig.2.
The Proflame 2 battery holder has a three position slider switch for system control. The slider switch 
can be set to one of three positions:

OFF position

With the slider in OFF position, the system is "OFF". No function can be selected by the transmitter.  
No "beep" will be emitted from the Proflame 2 IFC when a command is sent by pressing any key on 
the transmitter (for example the ON / OFF key).

ON position

With the slider in ON position, the burner flame is "ON". Only the other functions ( Fan, Lights, etc.) 
can be selected by the  transmitter. 

Remote position

With the slider in Remote position, all the functions can be selected by the  transmitter. 

Programming Button (PRG)
When pushed allows a transmitter to be accepted for use by the system.  See "Initializing the 
System for the first time"

0.584.920

0.584.922

CONNECT TO

IFC BOARD

X8 TERMINAL

CONNECT TO

IFC BOARD

X5 TERMINAL

CONNECT TO

BATTERY

HOLDER 6 PIN

TERMINAL

CONNECT TO

0.584.920

J1 TERMINAL

CONNECT TO

0.584.922

J1 TERMINAL