background image

8 1 0   E L E T T R O S I T

M U L T I F U N C T I O N A L   G A S   C O N T R O L

SIT Group

PIN 63AN7060/3

PUSH-BUTTON CONTROL

ALL ADJUSTMENTS ACCESSIBLE FROM ABOVE

THERMOELECTRIC SAFETY DEVICE

ON-OFF SOLENOID VALVE

Summary of Contents for 810 ELETTROSIT

Page 1: ...0 E L E T T R O S I T M U L T I F U N C T I O N A L G A S C O N T R O L SIT Group PIN 63AN7060 3 PUSH BUTTON CONTROL ALL ADJUSTMENTS ACCESSIBLE FROM ABOVE THERMOELECTRIC SAFETY DEVICE ON OFF SOLENOID VALVE ...

Page 2: ...let pressure test points Threaded gas inlet and outlet ready for flanged connection M A I N F E A T U R E S High flow multifunctional control complete with push button control off pilot on thermoelectric safety device for protection against improper operation main burner ignition enabling button pressure regulator on off solenoid valve with gas flow on off control On request a step ignition device...

Page 3: ...llation position any position Gas families I II and III Maximum gas inlet pressure 50 mbar Outlet pressure setting range 3 18 mbar on request 15 30 Working temperature range 0 60 C Pressure regulator Class C Automatic solenoid valve Class D Data refer to EN 126 1 Ignition button pilot position 2 Main burner ignition enabling button 3 Shutdown button 4 Pressure regulator setting device 5 Pilot gas ...

Page 4: ...EG ADJ ADJ I STEP PILOT ADJ 123 84 Rp 3 4 Rp 3 4 87 134 47 30 Pilot Ø 6 11 32 G G 0 5 Q m3 h d 0 6 4 2 6 8 10 Dp mbar 1 2 3 4 Rp 1 2 Rp 3 4 I Family d 0 45 Q 11 2 m3 h Q 12 9 m3 h Æp 5 mbar II Family d 0 6 Q 9 8 m3 h Q 11 2 m3 h Æp 5 mbar III Family d 1 7 Q 6 0 kg h Q 6 9 m3 h Æp 5 mbar Q m3 h d 0 6 Dp mbar Rp 3 4 Rp 1 2 ...

Page 5: ... manual versions The gas passage to the main burner is opened by powering the automatic solenoid valve The valve with step ignition device reaches the maximum flow after about 10 seconds Pilot flame ignition Fully depress the knob fig 1 to keep the main burner closed and the pilot flame lit Shutdown Fully depress the knob fig 3 CAUTION the restart interlock device prevents igni tion of the applian...

Page 6: ...quency of the coils indicated on the control are correct Check that all the connections in particular the earth are carried out to industry standards The 24Vac versions must be powered by an isolating transformer with very low safety voltage Carry out the connections in accordance with the rules for the appliance To access the supply and earth terminals unscrew the screw and remove the cover To ac...

Page 7: ...ral gas Adjustment screw 1st STEP ADJ With the screw 1st STEP ADJ in combination with the screw REG ADJ or with the buttons and it is possible to adjust the step ignition device so that the burner goes on gradually and silently Adjustment of the step ignition minimum flow with third family gases By completely unscrewing the screw NO P R and adjusting the screws REG ADJ and PILOT ADJ it is possible...

Page 8: ...tifunctional control for gas appliances with electrical power supply 9 955 721 R00 GRAPHIC DESIGN BY START PD ITALY SIT La Precisa Viale dell Industria 31 33 35129 PADOVA ITALY Tel 049 8293111 Fax 049 8070093 Telex 430130 SITEC I ...