T E C H N I C A L D A T A
D E S C R I P T I O N
ELECTRICAL DATA
Supply Voltage
(AC)
Consumption
(mA)
240 V 50 Hz
25
220 V 50 Hz
20
220 V 60 Hz
25
24 V 50 Hz
210
24 V 60 Hz
220
Electrical protection rating
IP54 using 160-type connectors
with screw and gasket - code
0.960.104
9
Actuation valve
10 Pilot outlet
11 Main gas outlet
12 Holes (M5) for mounting flange
13 Supplementary fixing points for valve
14 Connection point for combustion
chamber pressure regulator
compensation
1
Control knob
2
Pressure regulator cap screw
3
Pilot gas rate adjuster
4
Thermocouple connection
5
Alternative thermocouple connection
6
Provision for accessories support
bracket
7
Inlet pressure test point
8
Outlet pressure test point
7
8
9
6
10
11
2
1
3
4
12
5
13
• Gas connections:
Rp 1/2 ISO 7
• Installation positions:
any
• Gas families:
I, II and III
• Maximum gas inlet
pressure:
60 mbar
• Maximum outlet pressure
setting range:
3...30 mbar (optional 20...50)
• Working temperature
range:
0...70 °C (optional -20... +60°C)
• Pressure regulator:
Class B
• Automatic shut-off valve:
Class D (Class C on request)
Data refer to EN 126