3

4. DIMENSIONS                                        

       5. TITLE PAGE 

 

All measures in mm. 

 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

 
6. INPUTS AND OUTLETS 

 

6.1. INPUTS 

 

The unit has four digital inputs (D1,D2,D3,D4). 

Three of them work as switches (D1,D2 and D3), 
starting or stopping the corresponding programme, 
while the fourth one is a breakdown input (D4).  

The activation of inputs is done through their 

connection to the common.  

A time for the detection delay can be 

configured for every input, but the deactivation is 
immediate

.

 

 

 
 
 
 
 
The pH and conductivity reference, as well as 

the proportion between fertilisers can be configured 
for every input or programme 1, 2 and 3. If more than  

one input is activated at the same time, the 

programme which has priority is the one with the 
lowest cardinal number. 

Input 4, breakdown, is only taken into account if 

a programme is working. 

 

The unit also has an input for pH sensor 

(terminal type BNC) and another one for conductivity 
sensor. 

 

Summary of Contents for AGRONIC 54

Page 1: ... works on the solenoids another one with analogical injection which works on frequency variators In the by pulsed injection version to maintain the CE the unit applies every certain seconds a dose of every fertiliser which is related to the desired proportion between fertilisers and the programmed reference To maintain the pH the unit works in a similar way In the analogical injection version to m...

Page 2: ...t one If you keep pressing this key the code will change rapidly Use the and key to modify the values which are displayed on the screen These keys will increase or decrease the active value which is displayed in that moment If you keep pressing the key it increases or decreases rapidly 3 TECHNICAL CHARACTERISTICS Feeding Power source 12 Vdc Energy consumption Average consume 8 5VA Input fuse 4 A F...

Page 3: ... A time for the detection delay can be configured for every input but the deactivation is immediate The pH and conductivity reference as well as the proportion between fertilisers can be configured for every input or programme 1 2 and 3 If more than one input is activated at the same time the programme which has priority is the one with the lowest cardinal number Input 4 breakdown is only taken in...

Page 4: ...e and fertiliser by pulses The acid or base electrovalve is connected to S1 the fertiliser number 1 electrovalve to S2 and the fertiliser number 2 electrovalve to S3 Electrically the electrovalves will be connected directly to the outlets without any relay in between and hydraulically they will be connected to the venturis or to the magnetic pumps A1 A2 Analogical outlets from 0 to 10 volts to con...

Page 5: ...s introduced when the sensor value is outside the programmed reference value but within the allowed error The minimum time is 4 seconds and the maximum is 15 Codes 03 04 and 05 Proportional bands The limits within which the of injection will be calculated must b e indicated in these three codes one for every programme The lower the limit the more abrupt the changes will be when trying to obtain th...

Page 6: ...programme 1 2 and 3 are activated The value 00 means that this part is not to be regulated C2 2 6 6 3 Activated programme Conductivity reference programme 1 pH reference programme 1 Codes C5 C6 and C7 Indicate the desired proportion between the fertilisers of every one of the three programmes C6 3 0 11 Non activated programme Proportion of fertiliser 1 programme 2 Proportion of fertiliser 2 progra...

Page 7: ...g is stable enough and similar to the desired one the screen stops blinking indicating that the sensor has been calibrated If you press the and keys simultaneously the unit is forced to accept the value which is displayed at this moment If the calibration of sensor is not to be done press the C key during the initial seconds or press the C key until the code changes when the screen is blinking In ...

Page 8: ...8 13 FUNCTION CHART R 1078 ...