Sistemes Electrònics Progrés s.a. AGRONIC 54 Instruction Manual Download Page 1

 

1

 
 
 

 

 

 

INSTRUCTION  

                         

 

MANUAL 

 

 

 

 

 

 

 

 

 

 

12 Vdc 

 
 

INDEX 

 

Sec.  

Theme 

Page 

1. 

INTRODUCTION 

2. 

SCREEN DATA 

3. 

TECHNICAL CARACTERISTICS 

4. 

DIMENSIONS 

5. 

TITLE PAGE 

6. 

INPUTS AND OUTLETS 

6.1. 

     Inputs 

6.2. 

     Outlets 

7. 

CONFIGURATION OF THE INSTALLER 

8. 

CONSULTATION 

9. 

PROGRAMMING 

10. 

CONFIGURATION OF THE USER 

11. 

CALIBRATION 

12. 

BREAKDOWS 

13. 

FUNCTION CHART 

 
 

PRESENTATION 

 

We wish to take this opportunity to thank you for 

the confidence in us which you have demonstrated in 
expressing interest or acquiring Agrónic 54. 

This confidence, for our part, stimulates our 

efforts to meet and surpass the expectations of our 
clients to justify the traditional quality of our products. 

This Manual will allow you to see the capacity of 

the unit as well as its installation and use.  

However, if after reading this you still have any 

doubts, contact us and we will happily answer them.

 

 

 

1. INTRODUCTION 

 

Agrónic 54 is a unit which regulates both the 

electrical conductivity (EC) of irrigation water, injecting 
2 possible fertilisers, and its pH, injecting acid or base. 

There are 3 formulas or programmes, which are 

started by external orders received by the 
corresponding inputs. 

There are 2 versions, according to the way in 

which the dosage is done: one with “pulsed injection”, 
which works on the solenoids, another one with 
“analogical injection”, which works on frequency 
variators. 

In the “by pulsed injection” version, to maintain 

the CE, the unit applies every certain seconds, a dose 
of every fertiliser, which is related to the desired 
proportion between fertilisers and the programmed 
reference. To maintain the pH the unit works in a 
similar way. 

In the “analogical injection” version, to maintain 

the CE and/or the pH, the unit changes the injection 
speed of the engines until it gets the programmed 
references. 

In the version with pulsed injection, there are 

outlets for 2 fertilisers and 1 acid or base.  

In the version with analogical injection (0-10 

Vdc), there is an outlet for fertiliser and another one for 
acid or base. 

In both versions, there is also a general outlet 

and another one for alarm and/or agitator.  

Feeding of the unit at 12 Vdc and outputs as well 

to 12 Vdc. 

Outlets at 12  Vdc in the version with  pulsed 

injection and at 0-10 Vdc in the version with analogical 
injection.  

There are 3 inputs for the start of the fertilisation 

programmes and 1 input to detect breakdowns.  

There is also 1 input for the conductivity sensor 

and 1 for the pH sensor, with a transmitter, which is 
integrated in the unit circuitry.  

The calibration of sensors is done with the 

keyboard. 

It is possible to programme three different crops. 

The EC reference, pH reference and the proportion of 
two fertilisers to be applied (this is in the version with 

Summary of Contents for AGRONIC 54

Page 1: ... works on the solenoids another one with analogical injection which works on frequency variators In the by pulsed injection version to maintain the CE the unit applies every certain seconds a dose of every fertiliser which is related to the desired proportion between fertilisers and the programmed reference To maintain the pH the unit works in a similar way In the analogical injection version to m...

Page 2: ...t one If you keep pressing this key the code will change rapidly Use the and key to modify the values which are displayed on the screen These keys will increase or decrease the active value which is displayed in that moment If you keep pressing the key it increases or decreases rapidly 3 TECHNICAL CHARACTERISTICS Feeding Power source 12 Vdc Energy consumption Average consume 8 5VA Input fuse 4 A F...

Page 3: ... A time for the detection delay can be configured for every input but the deactivation is immediate The pH and conductivity reference as well as the proportion between fertilisers can be configured for every input or programme 1 2 and 3 If more than one input is activated at the same time the programme which has priority is the one with the lowest cardinal number Input 4 breakdown is only taken in...

Page 4: ...e and fertiliser by pulses The acid or base electrovalve is connected to S1 the fertiliser number 1 electrovalve to S2 and the fertiliser number 2 electrovalve to S3 Electrically the electrovalves will be connected directly to the outlets without any relay in between and hydraulically they will be connected to the venturis or to the magnetic pumps A1 A2 Analogical outlets from 0 to 10 volts to con...

Page 5: ...s introduced when the sensor value is outside the programmed reference value but within the allowed error The minimum time is 4 seconds and the maximum is 15 Codes 03 04 and 05 Proportional bands The limits within which the of injection will be calculated must b e indicated in these three codes one for every programme The lower the limit the more abrupt the changes will be when trying to obtain th...

Page 6: ...programme 1 2 and 3 are activated The value 00 means that this part is not to be regulated C2 2 6 6 3 Activated programme Conductivity reference programme 1 pH reference programme 1 Codes C5 C6 and C7 Indicate the desired proportion between the fertilisers of every one of the three programmes C6 3 0 11 Non activated programme Proportion of fertiliser 1 programme 2 Proportion of fertiliser 2 progra...

Page 7: ...g is stable enough and similar to the desired one the screen stops blinking indicating that the sensor has been calibrated If you press the and keys simultaneously the unit is forced to accept the value which is displayed at this moment If the calibration of sensor is not to be done press the C key during the initial seconds or press the C key until the code changes when the screen is blinking In ...

Page 8: ...8 13 FUNCTION CHART R 1078 ...