background image

A

A-  PREPARE THE DESIRED DRAINING EQUIPMENT TO ENSURE COMPLETE BACK BOX DRAINAGE IN UNDER 30 MINUTES:

 

NEW INSTALLATION:

 8" TO 12" (20-30cm) OF GRAVEL UNDER THE BACK BOX.

 

OVER EXISTING SURFACES:

 INSTALL A DRAINING PIPE TO THE BACK BOX.

B-  REMOVE THE DESIRED KNOCKOUT AND INSTALL AN APPROPRIATE ELECTRICAL CONDUIT (

NOT INCLUDED

) INTO THE BACK BOX.

C- FEED CABLE THROUGHT THE ELECTRICAL CONDUIT.

D- POUR CONCRETE IN AND MAKE SURE THAT THE BACK BOX OPENING IS FLUSH WITH THE CONCRETE.

A + B + C

D

scale 1:12

BACK BOX INSTALLATION

MEGAZIP

WALK-OVER ROUND MODELS: S8500, S8501, S8502, S8568, S8570, S8571, S8572, S8578

WALK-OVER SQUARE MODELS: S8580, S8581, S8582, S8588, S8590, S8591, S8592, S8598

INSTRUCTIONS SHEET

PAGE: 1 of 2

INS-685

9320 Boul. St-Laurent, suite 100, Montréal (Québec) Canada H2N 1N7

P.: 514.523.1339   F.: 514.525.6107  www.sistemalux.com

JP - R0

Last update: April 28, 2021

IMPORTANT -

 READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE. 

THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND ALL APPLICABLE LOCAL CODES, BY A PERSON FAMILIAR WITH THE 

CONSTRUCTION AND OPERATION OF THE PRODUCT, AND THE HAZARDS INVOLVED. PROPER GROUNDING IS REQUIRED FOR SAFETY.

8" - 12"

(20 - 30cm)

BACK BOX

DRAINING PIPE

NO!

OK!

NO!

C

B

CABLE

ELECTRICAL CONDUIT

(NOT INCLUDED)

KNOCKOUT

GRAVEL

BACK BOX

A

CONCRETE

CONCRETE WITH DRAINING PIPE

CONCRETE WITH GRAVEL

BEAM

ORIENTATION

WALL

SPOT, NARROW FLOOD,

FLOOD & ASSYMETRIC OPTIC

BEAM ORIENTATION

90°

Reviews: