9 - INSTALLATION

- WARNING -

THESE PROCEDURES MUST BE CARRIED OUT 

BY QUALIFIED STAFF

9.1 Preliminary operations 

The suction system is shipped to the customer completely assembled and packed
Before switching the machine on, the following checks are advisable: 
• Check that the packaging is intact. 
• Check that the appliance has not been damaged in any way and in particular check that all the protrud-
ing parts are intact. 
• Verify the correct tightening of the 

fi

 lter cartridge.

• Using the equipment list and the kit and accessories list, check that the equipment and the kit have 
been exactly and completely delivered.
• Check that the Guarantee Certi

fi

 cate has been provided. 

If any damage or irregularity is found or if any accessory is missing, do not install the appliance and 
contact your Retailer. 

9.2 Recommended installation 

The Tecno Star Dual Power vacuum cleaner must be connected to an exhaust air pipe, crucial for 
discharging outside the micropowders that the 

fi

 lter cartridge cannot retain. The vacuum cleaner must 

be installed in service rooms (e.g. garage, store room etc) protected from bad weather, dampness and 
excessive temperature variations. Install the unit in a place far from heat sources such as stoves and 
radiators. (N.B: the unit features IP 20 protection degree). 
During the set up phase, we suggest to always carefully check that the unit is positioned in the most 
suitable location selected for the system. Check also that suf

fi

 cient space has been allowed for instal-

lation, use and maintenance purposes and for an optimal recirculation of the air around the vacuum 
cleaner. 
Construction features allow the vacuum cleaners to be connected to the pipe system with pipes com-
ing either from right or left sides. In case of multi-storey vacuum cleaning system, we suggest you to 
install the unit on the lowest available 

fl

 oor.

Summary of Contents for 3116.2TS

Page 1: ...USE OF THE VACUUM CLEANER 12 8 EQUIPMENT AND ACCESSORIES 13 9 INSTALLATION 14 9 1 Preliminary operations 14 9 2 Recommended Installation 14 9 3 Transport and unpacking 15 9 4 Positioning of the vacuu...

Page 2: ...2 Changing parameters Autocleaner 34 12 MAINTENANCE 36 12 1 Programmed routine maintenance 36 12 2 Extraordinary maintenance 36 12 3 Cleaning the vacuum cleaner body cylinder 37 12 4 Emptying the dust...

Page 3: ...pliance with the Machinery Directive 2006 42 CE transposed into Italian Legislation by Decree Law 17 10 Low Tension Directive 2006 95 CE and Electromagnetic Compatibility Directive 2004 108 CE The sys...

Page 4: ...esearch applied to central vacuum cleaners and advanced electronic technology have al lowed TECNOPLUS S r l to create TECNO Star Dual Power The central vacuum cleaner suitable for any type of resident...

Page 5: ...e product features TURBO function by means two motors on a single micro line Safety thermal sensor to protect the motor Vacuum breaker valve to ensure the motor is not operating in critical conditions...

Page 6: ...G C 10 9 8 1 2 3 4 5 6 7 11 12 13 14 15 16 17 18 Cover Electronic board Pressure transducer On board computer Bin release handle Filter protection Filter cartridge Handle Base Wheels Motors group Air...

Page 7: ...supply V dc 12 Maximum air flow m3 h 390 Filtering surface cm2 17000 Dust bin capacity l 62 Air exhaust YES Air exhaust silencer YES Weight kg 55 A Size mm 615 B Size mm 633 C Size mm 1369 D Size mm 7...

Page 8: ...on 62 litres capacity equipped with wheels for handling Dust bag and bag stretcher for dust collection to ensure quick and healthy disposal operations of the material collected Soundproofed motor comp...

Page 9: ...the vacuum cleaner has been knocked or the outer body has been in any way damaged you think the system requires maintenance or repair Wear protective gloves and mask to carry out maintenance to empty...

Page 10: ...established by the health and environment protection regulations in force and do not contain SVHC classified substances Substance of Very High Concern in compliance with CE regulation 1907 2006 REACH...

Page 11: ...d to design and manufacture the appliances with screws that feature different characteristics TECNOPLUS s r l will immediately suspend the product guarantee in case of machine tampering car ried out b...

Page 12: ...es which are consid ered to be inappropriate and dangerous The system must not be used to vacuum clean fabrics heavy or hot burning materials The system must not be used to vacuum clean liquids Do not...

Page 13: ...ipe network 3 N 4 metal clamps to fix the sleeves 4 N 1 adhesive label detailing the system model 5 N 1 installation use and maintenance manual 6 N 1 silencer Check that the system the accessories and...

Page 14: ...and contact your Retailer 9 2 Recommended installation The Tecno Star Dual Power vacuum cleaner must be connected to an exhaust air pipe crucial for discharging outside the micropowders that the filte...

Page 15: ...h 9 3 Transport and unpacking Remove the protective cardboard box 1 2 Use a transpallet or a fork lift truck for transport and handling always maintain the system inside its own packaging until it rea...

Page 16: ...lable remove manually the unit from the pallet see picture In this case at least two strong per sons are needed to slide the unit while a third person removes the pal let WARNING do not tilt the unit...

Page 17: ...on the left Vacuum cleaners are generally supplied with suction and exhaust pipes on the right side RIGHT ver sion If needed the system can be transformed so as to have both suction and exhaust pipe c...

Page 18: ...l Disassemble the intake of the C exhaust pipe and the D closing sheet by removing the screws 3 After exchanging their housings reassemble the intake of the C exhaust pipe and the D closing sheet by f...

Page 19: ...ower vacuum cleaner features a control board from which the appliance func tions can be programmed by means of a simple operator s interface display with 6 function keys From the control board display...

Page 20: ...INE to the suction socket Connect the output cable for the auxiliary maintenance warning signal The use of this signal is OP TIONAL N B This signal is a normally open contact Insert the plug of the po...

Page 21: ...3 Rev 2 0 0 English 10 2 1 Auxiliary connection signal Example of connection of the auxiliary contact normally open which closes in case of alarms on the display Led indicator or 12V light Ext supply...

Page 22: ...acuum cleaner 11 2 Using the vacuum cleaner Position the main switch assembled on the right side on the appliance on I ON posi tion The display will switch on to indicate the unit is connected to the...

Page 23: ...ows the operator to send the inputs to the computer of the central unit in order to select the various functions programme the routine maintenance and upload specific data The data uploading is carrie...

Page 24: ...E 01 01 2013 12 00 Select the language by pressing the ar rows Up and Down Press Enter to select the language Press Esc to confirm the selected language and go to the next screen Set the date and time...

Page 25: ...2013 10 00 Suction OFF Depression mbar 000 PressENTER On this screen you will be able to save the details of the Service Write the tel ephone number by pressing the Up Down Left and Right arrows Press...

Page 26: ...re the suction if you activated the Suction stop option see par 11 4 2 FILTER ALARM Filter efficiency 0 clean the filter car tridge see par 12 7 1 DUST ALARM BIN Dust container level 100 empty the dus...

Page 27: ...lected sub menu Press Esc to exit 1 MENU Timer dust container Suction stop Maintenance Info Date time 11 4 1 Menu timer of the dust container Press the Up and Down arrows to modify the parameter Press...

Page 28: ...to confirm your choice and exit the menu Selection is active Selection is not active 11 4 3 Maintenance menu Press ESC to exit the menu 1 MAINTENANCE Filer efficinecy 100 Dust level 000 Allarm Service...

Page 29: ...n detail Installer Telephone number of the installer of the central vacuum system Service Telephone number of the authorized Service Center 3 Press the Up Down Right and Left ar rows to put the teleph...

Page 30: ...tup Press the Up and Down arrows to select the sub menus Press Enter to access the selected menu Press Esc to exit the menu 1 SETUP Turbo function Autocleaner Parameters Reset parameters Language Mode...

Page 31: ...PARAMETERS Timer Dust max 032 h Display stand by 005 min 11 5 3 Setup parameters In this menu you can modify the parameters relating to the functioning of the central vacuum unit set by the constructi...

Page 32: ...ines 2 users Timer dust max Set point timer max alarm dust container bin Standby display Set point timer activation display standby Selection is active Selection is not active 11 5 4 Set up reset para...

Page 33: ...spanol Press the Up and Down arrows to select the language Press Enter to activate the language Press Esc to confirm your choice and go back to the previous menu Press the Up and Down arrows to select...

Page 34: ...sys tem Autocleaner is connected see Appendix A 3 Selection is active Selection is not active Press Enter to activate the Autocleaner Press the Esc key to confirm the selec tion and return to the main...

Page 35: ...he new setting and return to the main screen 4 AUTOCLEANER Cycles number 05 Start 00 00 Stop 23 59 AUTOCLEANER Cycles number 05 AUTOCLEANER Start 00 00 AUTOCLEANER Stop 23 59 Parameter to set the numb...

Page 36: ...alled in case technical assistance is needed Furthermore when the alarm signals the need for routine maintenance dirty filter full dust bag and full dust bin the operator can decide whether to switch...

Page 37: ...riodically clean the outside casing of the appliance using a soft damp cloth with water and neutral soap Important only use water or neutral soap and water to clean the appliance The use of other sol...

Page 38: ...CENTRAL VACUUM SYSTEMS ByTecnoplus s r l Tie up the dust bag and remove it from the container 4 Introduce a new dust bag and the bag stretcher 5 Assemble the conveyor cone 6 Use both hands to lower t...

Page 39: ...3 Rev 2 0 0 English 12 5 Replacing the filter cartridge Lift the release handle using both hands Unscrew the blocking knob Screw the blocking knob 1 3 5 Remove the dust container 2 Replace the filter...

Page 40: ...TECNO Star Dual Power instruction manual 40 23 10 13 Rev 2 0 0 CENTRAL VACUUM SYSTEMS ByTecnoplus s r l Reassemble the dust container in its position 6 Use both hands to lower the clip handle 7...

Page 41: ...Any intervention of non authorized personnel will result in the invalidation of any guarantee of the product and the manufacturer will not be held responsible for any eventual damage to persons and o...

Page 42: ...ith the regulations in force 14 SOUND EMISSION A sound level measurement has been gauged by measuring the acoustic pressure and the sound level of the vacuum cleaner The test report is held at TECNOPL...

Page 43: ...system equal to or less than the limits set in the Setup menu see par 11 5 3 Check possible losses in the system Reduce the time of opening of the vacpan inlet valve if present Call the Technical Ser...

Page 44: ...TECNO Star Dual Power instruction manual 44 23 10 13 Rev 2 0 0 CENTRAL VACUUM SYSTEMS ByTecnoplus s r l...

Page 45: ...e Autocleaner system Loosen the Torsen screws to remove the cover made of thermoformed material Hook the autocleaner frame to the anchoring bracket and slide the centering strips in the slotted holes...

Page 46: ...retainer to connect them Disassemble the connec tor cover on the vacuum cleaner appliance 2 A 2 Pneumatic connection Approach the pipe connection of the vacuum system to the inlet on the rear side of...

Page 47: ...47 2 23 10 13 Rev 2 0 0 English...