background image

Detach the cold water supply hose from the cold water supply valve.
Attach the Quick Tee adapter inlet to the cold water supply valve outlet.
Attach the cold water supply hose to one Quick Tee adapter outlet.
Attach end of plastic supply tube to other outlet on Quick Tee adapter valve.
Route plastic supply tube up to SupraH

2

 Water System.

UNDER-COUNTER CONNECTION (Figure 2)

PRODUCT WATER SUPPLY CONNECTION

Locate the quick connector on back of machine below black water supply valve and 
rotate outward.
Insert end of plastic tubing into quick connector.

CONNECT POWER

 

Connect power jack to the port on the back of product.
Plug in the power cord.

WARNING

Sisel strongly recommends that you hire a licensed plumber to ensure 
proper installation and to prevent possible damage.

Rubber

Sealing Ring

Diverter Valve

Adapter

Faucet Diverter

FIGURE 1

Existing Water Line

to Faucet

New Suppy Line

Quick Tee

Adapter

Supply Stop

FIGURE 2

ATTENTION

The SupraH2 can be connected directly to the cold water supply. In order 
to do so, 

additional materials will need to be purchased separately

 

including a quick tee adapter and corresponding fittings.

INSTALLATION OF SUPRAH

2

 ULTRA WATER SYSTEM

WARNING

 DO NOT CONNECT TO HOT WATER!

Hot water may produce scale which can damage machine. Do not use the 
device for filtering and ionization of other liquids than water. Do not use 
the device if it appears to have been damaged in shipment.

ATTENTION

The SupraH2 Ultra Water Machine was designed for use with water from 
municipal water departments. Untreated water high in mineral content 
from private wells or other natural sources may damage the Supra H2’s 
components; in such cases, we strongly recommend installing a system 
to remove minerals. Sisel is not responsible for damage caused from the 
use of untreated water.

PRODUCT PLACEMENT

Place the product indoors on an even and stable place away from open flame or 
freezing areas but within easy access to power and water supplies.

FAUCET CONNECTION (Figure 1)

 

Remove the aerator screen (if any) from the faucet. Use the included faucet adaptors 
to attach water diverter (also included) to the faucet.
Insert end of plastic supply tube into quick connector on water diverter.

Water
Outlet

Hydrogen

Generator

Receptacle

Stand

Carbon

Filter

UF

Filter

Water Supply

Valve

Power

Water

Inlet

“Pure”
& “H

2

Buttons

“Start”
Button

Reviews: