230V AC
±
%10, 50/60Hz
or
12/
24V AC/DC %10, 50/60Hz
or
9-30V DC/7-24V AC
, 50/60Hz
±
Max. 7
VA
2.5mm²'lik
screw-terminal
±%1
S
cale
Sensitivity
Time Accuracy
Indıcator
EMC
START
INPUT
Input Type
Mechanical contact (Minimum = 50ms)
OUTPUT
O
ut
2 Relays
: 250V AC, 8A (for resistive load), NO and NC control output.
30.000.000 Switching for no-load operation; 300.000 switching for 8A resistive load at 250VAC.
Selectable
99:59
min.
or
hour.
1 second.
HOUSING
ENDA
ETM
2432
DIGITAL TIMER
2
60mm
5mm
77mm
3
5
m
m
GATE
INPUT
Input Type
RESET
INPUT
Input Type
G
A
T
E
S
T
A
R
T
R
E
S
E
T
+
1
2
V
8 6 8 0 4 0 7 7 1 1 7 0 3
8 6 8 0 4 0 7 7 1 1 7 1 0
1
2
3
4
5
6
7
8
9
10
ENDA
INDUSTRIAL ELECTRONICS
SN: XXXXXXXXX
ETM2432-230VAC
DIGITAL TIMER
230V AC +10% -20%
50/60Hz
11 12
Made In Turkey
O
U
T
1
250V AC 8A RESISTIVE LOAD
1
2
3
4
5
6
7
8
9
10
ENDA
INDUSTRIAL ELECTRONICS
SN: XXXXXXXXX
ETM2432-24
DIGITAL TIMER
24V AC/DC +10% -20%
50/60Hz
11 12
Made In Turkey
O
U
T
2
G
A
T
E
R
E
S
E
T
S
T
A
R
T
+
1
2
V
250V AC 8A RESISTIVE LOAD
O
U
T
1
O
U
T
2
71,5mm
2
9
,5
m
m
2
1
G
A
T
E
S
T
A
R
T
R
E
S
E
T
+
1
2
V
1
2
3
4
5
6
7
8
9
10
EN
DA
IN
DU
ST
RIA
L E
LE
CT
RO
NIC
S
SN
: X
XX
XX
XX
XX
ET
M2
43
2-2
30
VA
C
DIG
IT
AL
T
IM
ER
23
0V
A
C +
10
% -
20
%
50
/6
0H
z
11
12
Ma
de
In
T
urk
ey
O
U
T
1
25
0V
A
C 8
A R
ES
IS
TIV
E L
OA
D
O
U
T
2
8
68
04
07
71
17
10
Read this document carefully before using this device. The guarantee will be expired by device
demages if you don't attend to the directions in the user manual. Also we don't accept any
compensations for personal injury, material damage or capital disadvantages.
Thank you for choosing
ENDA ET
M2432
digital timer
.
*
77 x 35mm sized.
*
Dual contact output for timing control.
*
External start, reset, and gate inputs.
*
Hours - minutes and minutes - seconds indications can be selected.
*
Scale 0:01 .... 99:59 minutes
0:01 .... 99:59 hours
*
Time increasing and decrement steps can be adjusted.
*
Counting in downward direction.
*
Start and stop process can be controlled by the front panel.
*
8 different warning tones.
*
Upper and lower limits can be adjusted to setpoint value.
*
CE marked according to European Norms.
CONNECTION DIAGRAM
ENDA ETM2432
is intended for installation within control panels. Make sure that the device is
used only for intended purpose. The shielding must be grounded on the instrument side. During an
installation, all of the cables that are connected to the device must be free of electrical power. The
device must be protected against inadmissible humidity, vibrations, severe soiling. Make sure
that the operation temperature is not exceeded. All input and output lines that are not connected to
the supply network must be laid out as shielded and twisted cables. These cables should not be close to the
power cables or components. The installation and electrical connections must be carried out by a qualified staff
and must be according to the relevant locally applicable regulations.
7
8
SUPPLY:
NOTE :
184-253V AC
50/60Hz 5VA
Phase
Neutral
230V AC
Supply
Switch
Cable size: 1,5mm²
Fuse
F 100 mA
250V AC
Fuse should
be connected.
1) Mains supply cords shall meet the requirements
of IEC 60227 or IEC 60245.
2) In accordance with the safety regulations, the
power supply switch shall bring the identification of
the relevant instrument and it should be easily
accessible by the operator.
Note
TECHNICAL SPECIFICATIONS
ENVIRONMENTAL CONDITIONS
Ambient/Storage temperature
Relative Humidity
Protection Class
Height
0 ... +50 /
-25... +70
°C
°C
Max. humidity 80% for temperatures up to 31°C decreasing linearly to 50% relative humidity at 40°C.
According to EN60529; Front panel: IP65 Rear panel : IP20
Max. 2000m
ELECTRICAL CHARACTERISTICS
Supply
Power
C
onsumption
Wiring
Safety Requirements
Holding screw
0.4-0.5Nm.
Equipment is protected throughout by
DOUBLE INSULATION
Do not use the device in locations subject to corrosive and flammable gasses.
4 digits, 12.5mm, 7 segment red LED
EN 61326-1: 2013 (Performance criterion B is satisfied for EN 61000-4-3)
EN 61010-1: 2010 (Pollution degree 2, overvoltage category II)
Life Expectancy for Relay
For removing mounting clamps:
-
Push the flush-mounting clamp
in direction
1
as shown in the
figure below.Then, pull out the
clamp in direction
2
.
Dimensions
Depth
Flush mounting
clamp
Panel
Rubber
Packing
Flush mounting
clamp
Note: 1)
Panel thickness should
be maximum 7mm.
2)
If there is no
t
60mm free
space at the back side of
the device,it would be
difficult to remove it from
the panel.
Panel Cut-out
Mechanical contact (Minimum = 50ms)
Mechanical contact (Minimum = 50ms)
according to DIN 43 700.
Suitable for flush-panel mounting
5
1
W77xH3 xD7 mm
Approx. 198g (A
)
fter packing
Self extinguishing plastics
While cleaning the device, solvents (thinner, benzine, acid etc.) or corrosive materials must not be used.
Housing Type
Dimensions
Weight
Enclosure Materials
Order Code : ETM2432 -
1
1 - Supply Voltage
230VAC...230V AC
24............24V AC/DC
12............12V AC/DC
SM............9-30V DC / 7-24V AC
SET
SET
ETM232
ENDA
OUT1
H
M
SET
SET
ETM2432
ENDA
OUT1
OUT2
HOUR
MIN
START
STOP
DIGITAL TIMER
SET
SET
ETM232
ENDA
OUT1
H
M
SET
SET
ETM2432
ENDA
OUT1
OUT2
HOUR
MIN
START
STOP
DIGITAL TIMER
ETM2432-
E
-0
1
-151012
SİSEL MÜHENDİSLİK ELEKTRONİK SAN. VE TİC. A.Ş.
Şerifali Mah.
Y.Dudullu 34775
ÜMRANİYE/İSTANBUL-TURKEY
Tel : +90 216 499 46 64 Pbx. Fax : +90 216 365 74 01
url : www.enda.com.tr
Barbaros Cad. No:18
ENDA
TM
1/4