SET
°C
SET
ET1413R
ENDA
COAL
CIR
FAN
COAL
Themperature set
value for
COAL
Coal
Stoking Coal
Duration
C.dur
Fan
Lower limit for
circulation set
value
C.Lol
C.int
A.Lol
C.upl
A.upl
Parameter
security code
60.0
8
60.5
20.0
5.0
0.0
50.0
90.0
0
Can be adjusted between
0.0
°C
and
C.upl
paramet
er.
In order to setting up the parameter access options, specified security
code must be entered. Once the security code has been entered,
AccS
parameter can be accessed by using key.
CIR.SET
0.5
+
Programming Mode
Measurement
value
1000
Running Mode
22.0
30.0
29.9
30.0
Pfa
Thermostat probe
or line is short circuited
PsC
Thermostat probe not connected, broken or probe faulty.
Error Messages
Measured
value is
higher than the scale
Measured
value is
lower than the scale
C.int
Coal
Coal 0.5
-
CIR
.SET
NTC Input
t
t
Fan
Fan 0.5
-
t
t
CIRCULATION
Output
If the measurement value is blinking on display,
measured value is out of alarm scale limits.
23.5
Output Table
Initial Value
Hysteresis value for
FAN,
CIRCULATION
and
COAL outputs.
HYS.
2.0
C.dur
C.int
C.dur
---
COAL
LED
CIRCULATION
LED
FAN
LED
COAL
output will be active as long as
COAL
key is pressed while in
"Running Mode"
. In
"Programming Mode"
, provides the
menu selection and increases the parameter value. In
"Running Mode"
, by using together with the SET key, provides the
increases the set value. If pressed continuously, value increases rapidly.
In
"Running Mode"
, indicates the measurement temperature value. In
"Programming Mode"
, indicates the current parameter's
name or parameter's value.
S.cod
Err.
Accs.
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
oFF
Temperature
Offset Value
0.0
SET
2/2
Parameter access options are determined by this parameter.
If
P.no
is selected, the parameters are visible but values can
not be changed. If
P.YES
is selected, values of all parameters
can be changed.
ET1413R-EN-01-170404
In
"Programming Mode"
, provides the parameter selection and decreases the parameter value. In
"Running Mode"
, by using
together with the SET key, provides the decreases the set value. If pressed continuously, value decreases rapidly.
In
"Running Mode"
, provides the set value . In
"Programming Mode"
, provides the configuring to selected parameter value.
In order to configuring a selected parameter, press and hold down to key and perform the desired settings by using
navigation keys.
SET
If key is pressed in "Running Mode",
CIRCULATION
set value displayed and desired value can
be set by using navigation keys. Initial setpoint value for circulation is
35.0
°C .
if keys are pressed together for 3 seconds,
“Programming Mode” is entered.
if keys are pressed together,
“Running Mode” is entered.
Themperature set
value for
FAN
Time between
Stoking Coal
processes
Upper limit for
circulation set
value
Lower limit for
alarm set
value
Upper limit for
alarm set
value
Can be adjusted between
0.0
°C and
120.0
°C
Can be adjusted between
0.0
°C and
120.0
°C
Can be adjusted between
0
and
1
5
0
seconds. If set as
0
,
coAL
output is disable.
Can be adjusted between
0
.0
and
1
5.
0
minutes. If set as
0.0
,
coAL
output is enable.
Can be adjusted between
-2
0.0
°C and
20.0
°C
Can be adjusted between
CLoL
parameter and
150.0
°C.
Can be adjusted between
0.0
°C
and
A.uPL
paramet
er.
Can be adjusted between
A.LoL
parameter and
150.0
°C.
Can be adjusted between
0.1
°C and
20.0
°C
COAL
Output
FAN
Output