SN: XXXXXXXXX
ET1413R-NTC-230VAC
DIGITAL THERMOSTAT
ENDA
INDUSTRIAL ELECTRONICS
2
3
0
V
A
C
+
1
0
%
-
2
0
%
5
0
/6
0
H
z
4
.5
V
A
C
IR
C
U
L
A
T
IO
N
2
5
0
V
A
C
8
A
R
E
S
IS
T
IV
E
L
O
A
D
C
O
A
L
2
5
0
V
A
C
8
A
R
E
S
IS
T
IV
E
L
O
A
D
N
T
C
S
E
N
S
O
R
F
A
N
2
5
0
V
A
C
8
A
R
E
S
IS
T
IV
E
L
O
A
D
1
2
3
4
5
6
7
8
9 10 11 12
1
2
V
A
C
/D
C
1
0
%
5
0
/6
0
H
z
4
.5
V
A
±
SN: XXXXXXXXX
ET1413R-NTC-12
DIGITAL THERMOSTAT
ENDA
INDUSTRIAL ELECTRONICS
C
IR
C
U
L
A
T
IO
N
2
5
0
V
A
C
8
A
R
E
S
IS
T
IV
E
L
O
A
D
C
O
A
L
2
5
0
V
A
C
8
A
R
E
S
IS
T
IV
E
L
O
A
D
N
T
C
S
E
N
S
O
R
F
A
N
2
5
0
V
A
C
8
A
R
E
S
IS
T
IV
E
L
O
A
D
1
2
3
4
5
6
7
8
9 10 11 12
2
4
V
A
C
/D
C
1
0
%
5
0
/6
0
H
z
4
.5
V
A
±
SN: XXXXXXXXX
ET1413R-NTC-24
DIGITAL THERMOSTAT
ENDA
INDUSTRIAL ELECTRONICS
C
IR
C
U
L
A
T
IO
N
2
5
0
V
A
C
8
A
R
E
S
IS
T
IV
E
L
O
A
D
C
O
A
L
2
5
0
V
A
C
8
A
R
E
S
IS
T
IV
E
L
O
A
D
N
T
C
S
E
N
S
O
R
F
A
N
2
5
0
V
A
C
8
A
R
E
S
IS
T
IV
E
L
O
A
D
1
2
3
4
5
6
7
8
9 10 11 12
1/
2
SET
°C
SET
ET1413R
ENDA
COAL
CIR
FAN
COAL
3
5
m
m
77mm
SET
°C
SET
ET1413R
ENDA
COAL
CIR
FAN
COAL
SN
: X
XX
XX
XX
XX
ET
14
13
R-N
TC
-2
30
VA
C
DIG
IT
AL
T
HE
RM
OS
TA
T
EN
DA
IN
DU
ST
RIA
L E
LE
CT
RO
NIC
S
2
3
0
V
A
C
+
1
0
%
-2
0
%
5
0
/6
0
H
z
4
.5
V
A
C
IR
C
U
L
A
T
IO
N
2
5
0
V
A
C
8
A
R
E
S
IS
T
IV
E
L
O
A
D
C
O
A
L
2
5
0
V
A
C
8
A
R
E
S
IS
T
IV
E
L
O
A
D
N
T
C
S
E
N
S
O
R
F
A
N
2
5
0
V
A
C
8
A
R
E
S
IS
T
IV
E
L
O
A
D
1
2
3
4
5
6
7
8
9
10
11
12
1 -
Supply Voltage
230.....
...
230V AC
24 ........24V AC/DC
12 ........12V AC/DC
ET1413R-NTC -
1
Order Code :
ET1413R-EN-01-170404
ENDA
TM
SİSEL MÜHENDİSLİK ELEKTRONİK SAN. VE TİC. A.Ş.
Şerifali Mah.
Y.Dudullu 34775
ÜMRANİYE/İSTANBUL-TURKEY
Tel : +90 216 499 46 64 Pbx. Fax : +90 216 365 74 01
url : www.enda.com.tr
Barbaros Cad. No:18
Please read this document carefully before using this product. The guarantee will be invalidated if the
device is damaged by not following instructions detailed in the manual. The company shall not be
responsible for any damage or losses however caused, which may be experienced as a result of the
installation or use of this product.
ENDA ET1413R RADIATOR CONTROLLER
Thank you for choosing
ENDA ET1413R
Radiator Controller.
3
5
x 77mm sized.
On-Off control.
CIRCULATION, COAL and FAN control outputs.
Coal output can be set by depending on temperature
duration or manually.
Upper and Lower alarm limits can be configured to
dependent on set value.
CE marked according to the European Norms.
Upper and Lower setpoint value limits can be adjusted.
Connection Diagram
ENDA ET1413R
is intended for installation in control panels. Make sure that the device is used only
for intended purpose. The electrical connections must be carried out by a qualified staff and must be
according to the relevant locally applicable regulations. During an installation, all of the cables that
are connected to the device must be free of electrical power. The device must be protected against
inadmissible humidity, vibrations, severe soiling and make sure that the operation temperature is
not exceeded. The cables should not be close to the power cables or components.
Holding screw
0.4-0.5Nm.
Equipment is protected throughout by
DOUBLE INSULATION
SUPPLY:
NOTE:
184-253V AC
50/60Hz 4VA
Line
Neutral
230V AC
Supply
Switch
Note:
Cable size: 1,5mm²
Fuse
F 100 mA
250V AC
Fuse should
be connected
1)
Mains supply cords shall meet the requirements of
IEC 60227 or IEC 60245.
2)
In accordance with the safety regulations, the power
supply switch shall bring the identification of the
relevant instrument and it should be easily
accessible by the operator.
7
8
Technical Specifications
CONTROL
ENVIRONMENTAL CONDITIONS
Ambient / Storage
T
emperature
Relative Humidity
Protection class
Height
Do not use the device in locations subject to corrosive and flammable gasses.
ELECTRICAL CHARACTERISTICS
Supply Voltage
Power Consumption
Connection
Scale
Sensitivity
/
Accuracy
Time Accuracy
Display
EMC
Safety Requirements
OUTPUTS
Coal Output Relay
Circulation Output Relay
Fan Output Relay
Control
T
ype
Control
A
lgorithm
Hysteresis
HOUSING
Housing Type
Dimensions
Weight
Enclosure Material
Max. 2000m
0 ... +50°C/-25 ... 70°C (without icing)
According to EN60529; Front panel : IP65
Rear Panel : IP20
Relative humidity 80% for temperatures up to 31°C decreasing linearly to 50% relative humidity at 40°C.
Max.
4.
5VA
2.5mm² screw-terminal connections
For Time Unit (±% 1-15sec), For Minute Unit (±% 1-1sec)
4 digits, 12.5mm, 7 segment LED
EN 61326-1: 2013
(Provides performance criterion B for EMC experiments.
The device is intended for use in controlled electromagnetic environments.)
EN 61010-1: 2010 (Pollution degree 2, overvoltage category II)
0 ... +150.0°C
0.1°C
/
±1°C
230V AC +%10 -%20, 50/60Hz ; 12V AC/DC
± %
10 or 24V AC/DC
±%
10
NO
250V AC, 8A (
), 1/2hp, 0.37kW 240V AC CosF = 0.4 (
)
+NC
for resistive load
for inductive load
NO 250V AC, 8A (for resistive load), 1/2hp, 0.37kW 240V AC CosF = 0.4 (for inductive load)
NO 250V AC, 8A (for resistive load), 1/2hp, 0.37kW 240V AC CosF = 0.4 (for inductive load)
Single set-point control
On-Off control
Adjustable between 1 ... 20.0
°C.
Suitable for flush -panel mounting
W77xH35xD
7
1mm
Approx. 190g (After packing)
Self extinguishing plastics.
While cleaning the device, solvents (thinner, gasoline, acid etc.) or corrosive materials must not be used.
Life Expectancy for Relay
30.000.000 Switching for no-load operation; 300.000 switching for 8A resistive load at 250VAC.
DIMENSIONS
Note:
1)
Panel thickness should
be maximum 7mm.
2)
If there is no 60mm free
space at the back side of
the device,
it would be
difficult to remove it from
the panel.
Flush mounting
clamp
For removing mounting clamps:
-
Push the flush-mounting
clamp in direction
1
as shown
in the figure below.Then,pull
out the clamp in direction
2
.
71,5mm
2
8
,5
m
m
Panel Cut-out
71mm 5mm
Flush mounting
clamp
Panel
Rubber
packing
2
Depth
1