PARAMETERS TABLE
inp.
4 20
Parameter
Options
/ [units]
Description
0 20
conf.
Configuration menu
0 10
1 5
2 10
0 5
pot.
manu.
4-20mA
0-20mA
0-10V
1-5V
2-10V
0-5V
Potentiometer input.
Manual Running Mode.
disp.
out
curr.
Output as Percentage in Running Mode.
Output as Current in Running Mode.
c.typ.
phaS.
croS.
Control with phase angle.
Control with Zero-cross.
St.ti.
Soft
ic.St.
Output is energized with soft start.
Output is energized with kick start.
Err.c.
auto
Stop
Returns to Running Mode when error disappeares.
Remains in Eror Mode when error disappeares.
out.c.
Output Control Menu
ou.hi.
Takes a value between
ou.lo.
and
100
.
ou.lo.
Takes a value between
0 .
and
ou.hi
.
cu.hi.
Takes a value between
0
and load current.
Start duration (0 - 200).
ou.of.
Takes a value between
-50.
and
50
.
[Ampere]
[Second]
[%]
[%]
[%]
5ECU
Security Menu
a.con.
Configuration menu invisible.
Configuration menu can be changed.
Only configuration menu visible.
a.out.
Output control menu invisible.
Output control menu can be changed.
Only Output control menu visible.
Input selection.
Programming Mode
inp.
If, and
keys are pressed, Programming Mode is entered.
than
Control type
selection.
c.typ.
Start type
selection.
st.ty.
Running Mode
display selection.
disp.
st.ti.
Data menu security
parameter.
A.out..
A.con.
Control menu security
parameter.
codE.
Security menu access
code is 124.
Max. acceptable
value for output.
Min. acceptable
value for output.
ou.hi.
ou.lo.
Start duration.
ou.of.
If
Err.c
parameter is set as
stop
, only when key is pressed,
auto
,
when key is pressed or when the error disappeared, it returns to Running Mode. When return to the
operating mode. If overheating continues device passes to the Eror Mode.
If
Err.c
parameter is set as
Output offset value.
Err.c.
Quit method
from error status.
conf.
out.c.
SET
SET
sECU.
St.ty.
nonE
p.yES
p.no
nonE
p.yES
p.no
Default
values
out
phaS.
Soft
4
auto
p.yES
p.yES
100
0
0
SET
SET
SET
If held down key, the selected parameter will flash and can be adjusted to desired value with the keys.
Parameter Adjustment Method
ou.hi
51
50
50
If keys are pressed for 0.4 seconds parameter changes faster.
SET
SET
SET
SET
SET
cu.hi.
Running
Mode
a. 3.0
o. 30
diSp.
=
curr.
Output as
Current.
diSp.
=
out
Output as
Percentage.
If key is pressed in Running Mode for 3 seconds, Manuel Running Mode is entered.
Flashing manual output value is set to the desired value with the keys. When key is
pressed, desired set value is saved and Running Mode is returned.
SET
SET
SET
SET
Manual Running Mode
If 20 seconds have without pressed any key, information is saved
and returned to Running Mode.
Or; if pressed
together,
automatically
and than keys, access to menu headers are entered. By pressing and than
keys are pressed
information is saved and returns to Running Mode.
SET
+
+
+
+
+
m. 50
m. 51
m. 50
(**)
0 10
(If
disP.
=
curr.
)
Max. current value for
connected load
in
curr.
selection
ERFA1 device does not measures the load current. It indicates
the calculated current value for according to the entered
cu.hi.
parameter.
Psc
Err.1
When the device overheats,
Err.1
appears on display and enters to error mode.
Error Messages
Psc
Err.2
If input values are selected as 4-20 or 0-20 and if above current flows,
Err.2
appears on display
and enters to error mode.
m.sft.
Output is energized with soft start according to manual output value.
m.ic.S.
Output is energized with kick start according to manual output value.
Device starts at
"Running Mode"
in every power-up.
Factory Settings
If key is held down while the device is powered up,
d.PAr
message will appears and factory settings will be restored.