sisel ENDA EI741A Quick Start Manual Download Page 2

TERMS

     4 digits  7 segment red LED display

  ( 2 ),( 3 ),( 4 ),( 5 ) Tuþ takýmý

  ( 1 ) Digital display

Panel cut-out

Connection
cables

Depth

97mm

75mm

8

4

m

m

DIMENSIONS

 68     mm

+0.7

 6

8

  

  

 m

m

+

0

.7

Rubber packing

Flush mounting 

clamp

Panel

7

2

m

m

7

8

m

m

1

2

 2/3

EI741A-E-05

CONNECTION DIAGRAM

10

9

184-253V AC 
50/60Hz 7VA

230V AC 
Supply

Switch

Cable size: 1,5mm²

Fuse

F 100 mA 

250V AC

Neutral

Line

SUPPLY :

NOTE :

Fuse should
be connected

1) Measurement value, measurement unit, the minimum or the maximum measured values are 
    displayed in the run mode.
    Parameter name, parameter value or a user defined unit is displayed in the programming mode.

3) De
    Used for making the minimum and the maximum measured values equal in the run mode.

crement or parameter selection key in the programming mode.

2) Increment or parameter selection key in the programming mode.
    Used for displaying measurement unit or the max. measured value in the run mode.

4) Menu selection key in the programming mode.
    
   

Used for displaying the  minimum measured value in the run mode.

5) Used for selecting run and programming modes,

displaying 

    measurement unit or 

 

 

 adjusting parameters, 

making the minimum and the maximum measured values equal.

ENDA

PROGRAMMABLE INDICATOR

PRG

SHIFT

MIN.

MAX.

UNIT

RESET

D.P.

SET

EI 741A

 14mm       

      Micro switch

         Character height

ENDA

ENDA

ENDA

ENDA

ENDA

ENDA

EI741A INDICATOR

EI741A-24AC INDICATOR

EI741A-24DC INDICATOR

EI741A-ASXX INDICATOR

EI741A-24AC-ASXX
INDICATOR

EI741A-24DC-ASXX
INDICATOR

INDUSTRIAL ELECTRONICS

INDUSTRIAL ELECTRONICS

INDUSTRIAL ELECTRONICS

INDUSTRIAL ELECTRONICS

INDUSTRIAL ELECTRONICS

INDUSTRIAL ELECTRONICS

INPUT

INPUT

INPUT

INPUT

INPUT

INPUT

GND

GND

GND

GND

GND

GND

GND

GND

GND

5

5

5

6  

6  

6  

7  

7  

7  

7  

7  

7  

8  

8  

8  

8  

8  

8  

9  

9  

9  

9  

9  

9  

10  

10  

10  

10  

10  

10  

SN: XXXXXXXXX

SN: XXXXXXXXX

SN: XXXXXXXXX

SN: XXXXXXXXX

SN: XXXXXXXXX

SN: XXXXXXXXX

230V AC +10% -20% 

50/60Hz 7VA

24V AC ±10% 
50/60Hz 7VA

24V DC ±10% 

 7VA

24V AC ±10% 
50/60Hz 7VA

24V DC ±10% 

 7VA

230V AC +10% -20% 

50/60Hz 7VA

AUXILIARY SUPPLY 

OUT XXV XXmA

AUXILIARY SUPPLY 

OUT XXV XXmA

AUXILIARY SUPPLY 

OUT XXV XXmA

Note  1) While panel mounting, additional distance required for
              connection cables should be considered.
          2) Panel thickness should be maximum 10mm.
          3) If there is no 90mm free space at back side of the device,
              it would be difficult to remove it from the panel.
  

 

 -  

Push up the flush-mounting 

     clamp in direction 

1

 as    

     

shown in the figure above.

 

 -  

Then, pull out the clamp in  

     

direction 

2.

 

For removing mounting clamps:

ENDA EC762 is intended for installation in control panels. Make sure that the device is used only for intended purpose. 

During an installation, all of the cables that are connected to the device must be free of energy. The device 

must be protected against inadmissible humidity, vibrations, severe soiling and make sure that the operation temperature is not exceeded. All 
input and output lines that are not connected to the supply network must be laid out as shielded and twisted cables. These cables should not be 
close to the power cables or components. 

The shielding must be 

grounded on the instrument side. 

The installation and electrical connections must be carried on by a qualified staff and must be 

according to the relevant locally applicable regulations.  

1) Mains supply cords shall meet the requirements of  IEC 60227 or IEC 60245. 
2) In accordance with the safety regulations, the power supply switch shall bring the identification of the relevant instrument and it

  

 should 

 

be easily accessible by the operator.

Note :

Holding screw
0.4-0.5Nm 

Equipment is protected throughout
by DOUBLE INSULATION.

ENDA

PROGRAMMABLE INDICATOR

PRG

SHIFT

MIN.

MAX.

UNIT

RESET

D.P.

SET

EI 741A

Reviews: