SET
-
30.0
-
29.9
-
30.0
1000
-
24.0
uPL
Hy5
C.Fos
C.Fos
C.Fo5
uPL
unl
2. Locking / Unlocking the Keys
6. Changing the Parameter Values
C.dI5
C.Enb
1000
-
24.0
Loc
Locked
Unlocked
1000
-
24.0
DEFROST LED :
Lights up during the defrost process is running.
°F FAHRENHEIT LED :
Lights up when the parameter value or the measured temperature is in ° F.
This LED lights up if a parameter is displayed in the hidden menu, if also available in the user menu.
COMPRESSOR LED :
Lights up if the compressor output is active and it flashes while waiting for compressor delay time.
Used for displaying and configuring a selected parameter value.
Used for increasing the setpoint value and changing parameters.
When held down for a few seconds, configured numeric value increases faster.
Used for decreasing the setpoint value and changing parameters.
When held down for a few seconds, configured numeric value decreases faster.
HEATING LED :
Lights up when the output is active during heating control.
SET
SET
SET
SET
SET
SET
SET
SET
SET
1
2
3
4
5
6
7
8
9
18
17
16
15
14
13
12
11
10
ENDA
SET
°C
°F
EDT5412A
PsC
Pfa
Displayed measuring value flashes if an alarm
condition occurs. If
5nd
parameter
is not
set to
0
, buzzer will sound. Buzzer can be silenced
by pressed key.
-
24.0
EA
5
A
2
/
4
FRONT PANEL COMMANDS
1. Viewing and Changing The Setpoints
Measurement
value
If key is pressed for 3 seconds in "Running Mode", setpoint value is displayed and it can be changed by using navigation keys.
3.Manual Defrost Settings
To locking or unlocking the keypad, keys are pressed together for 2 seconds.
Loc
or
unL
message will appears for valid status.
During
Loc
status, just the setpoint value will appear if the key is pressed.
Measurement
value
4.Manual Lighting Settings
When key is pressed for 2 seconds while the
otYP
parameter is set to
Lght
, the lighting output status changes (active or inactive).
When key is pressed for 2 seconds in “Running Mode” while the
o.tYP
parameter is set to
dEF
, defrost process will start or stop manually.
The defrosting process will be disabled if the
d.dur
parameter is set to 0.
5.Activating / Inactivating The Control Outputs
Measurement
value
Control output inactive.
Control output active.
In "Running Mode", if the key is pressed for 2 seconds
C.di5
message appears, control outputs become inactive and the device runs as indicator.
If key is pressed for 2 seconds during control outputs are inactive
C.Enb
message appears and the control operation continued.
If keys are pressed together for 2 seconds, message appears and the user menu is entered, and the first parameter of the user menu is
displayed. The parameter value can be displayed by pressing key and can be changed by using navigation keys.
If no operation is performed for 3 seconds while a parameter value displayed or by pressing to key, the parameter name will be re-displayed.
If keys are pressed together while the parameter name displayed, "Running Mode" is entered immediately.
Program
ming Mode
7. Hidden Menu
If key is pressed for 7 seconds, message appears and the hidden menu is entered, and
R2
parameter is displayed.
The parameter value can be displayed by pressing key and can be changed by using navigation keys.
Parameter accessing and/or saving operation can be performed as same as user menu.
8. Transferring the Parameters Between Menus
By pressing to keys together for 2 seconds, the parameter can be
transferred to user menu. Up to 8 parameters can be transferred to the user menu.
If keys are pressed for 2 seconds, parameter will be removed from user menu. °F LED is continuously lit if a parameter is
present in the hidden menu.
If no parameter is stored in the user menu,
nP
message will be displayed.
ERROR MESSAGES
No communication with the thermostat probe.
Probe and/or cable broken or not connected)
Thermostat probe or
c o n n e c t i o n l i n e
short-circuited.
Temperature value is
higher than the scale.
Temperature value is
lower than the scale.
External alarm is active but
the outputs are not affected.
External alarm is active and the
relay outputs are in OFF situation.
Buzzer can be silenced by pressed
any key.
ALARM SITUATION
Power-up the device by pressing and holding down the key for factory defaults.
d.PAr
message will be displayed if the operation success.
FACTORY DEFAULTS