sisel ENDA EDT2423A Quick Manual Download Page 1

ENDA

TM

ENDA

  EDT2423A

  is  intended  for  installation  in  control  panels.  Make  sure  that  the  device  is  used

only  for  intended  purpose.  The  electrical  connections  must  be  carried  out  by  a  qualified  staff
and must be according to the relevant locally applicable regulations. During an installation, all of the cables  
that 

are connected to the device must be free of electrical power.

Thank you for choosing  

ENDA EDT2423A

 temperature controller

1/4

  ENDA

 

EDT

2

4

23A

 

TEMPERATURE CONTROLLER

CONNECTION DIAGRAM

ENVIRONMENTAL CONDITIONS

 

Height

 Max. 2000m

 

Ambient/storage temperature

 

Relative humidity

0 ... +50°C/-25 ... 70°C (

without icing

)

Protection class

According to EN60529;      Front panel : IP65
                                    

       

Rear Panel : IP20

                                               

 Do not use the device in locations subject to corrosive and flammable gasses.

 

Supply voltage

 

Power consumption

Max. 5VA
2.5mm² screw-terminal connections

   ±1% 
   4 digits, 12.5mm, 7 segment  LED

 

Connection

 S

cale

 

Sensitivity

 Accuracy

 

Time accuracy

 

Display

 EMC
 

Safety requirements

 

 EN 61326-1: 2013 
 EN 61010-1: 2010 (Pollution degree 2, overvoltage category II)

ELE

CTRICAL CHARACTERISTICS

-60.0 ... +150.0°C (-76.0 ... +302.0°F)

0.1°C (Can be selected as 0.1

ºC 

or

 1ºC

.) 

±1°C  

CONTROL

 

Control type

 Single set-point control
 On-Off control

 

Control algorithm

 H

ysteresis

 Adjustable between 1 ... 20.0

 

°C.

OUTPUTS

HOUSING

 

Housing type

 Suitable for flush -panel mounting

 

Dimensions

  

 W77xH35xD61mm 

 

Weight

 

 Approx. 190g (After packing)  

 

Enclosure material

 Self extinguishing plastics.

 While cleaning the device, solvents (thinner, benzine, acid etc.) or corrosive materials must not be used.

Relative humidity 80% for temperatures up to 31°C decreasing linearly to 50% relative humidity at 40°C.

  Fan relay output

Defrosting relay output 

Compressor relay
output

Life expectancy

For 

EDT2423A

-X-R; Without load 30.000.000 switching; 250V AC, 8A (resistive load) 100.000 switching.

For EDT2423A-X-R ; Relay : NO 250V AC, 8A ,1/2hp, 0.37kW 240V AC  
                                                       
                                             

Device must be protected against inadmissible  humidity, vibrations, severe soiling and make sure that the operation 
temperature is not exceeded. The cables should not be close  to the power cables or components. 

Equipment is protected throughout by 

DOUBLE INSULATION

SUPPLY:

NOTE:

184-253V AC 
     veya 
10-30V DC /
     8-24V AC
 50/60Hz 5 VA

Line

Neutral

230V AC
Supply

 

Switch

Note: 

Cable size: 1,5mm²

Fuse 

F 100 mA 

250V AC

Fuse should 
be connected

1)

 Mains supply cords shall meet the requirements of  

    

IEC 60227 or IEC 60245. 

2)

 In accordance with the safety regulations, the power 

    

supply switch shall bring the identification of the 

    

relevant instrument and it should be easily 

    

accessible by the operator.

1

2

DIMENSIONS

 Note:  

1)

 Panel thickness should

be maximum 7mm.

2)

 If there is no 60mm free

space at the back side of
the device,it would be 
difficult to remove it from
the panel. 

Flush mounting

clamp

For removing mounting clamps:  

Push the flush-mounting 

clamp in direction 

1

 as shown 

in the figure below.Then,pull
out the clamp in direction 

2

 .

 

71,5mm

2

8

,5

m

m

Panel cut-out

  61mm                    5mm

  Flush mounting
         clamp

Panel

Rubber
 packing

2

Depth

77mm

3

5

m

m

1

      

EDT2423A-EN-07-220103

EN

DA

 

IN

DU

ST

RIA

L E

LE

CT

RO

NIC

S

SN

: X

XX

XX

XX

XX

E

N

D

A

K

E

Y

23

0V

 A

C

 +

10

%

 -2

0%

50

/6

0H

z  

5V

A

86

80

40

77

02

42

8

1

2

3

4

5

6

7

8

ED

T2

4

1

2-2

30

DIG

IT

AL

 D

EF

RO

ST

 

TH

ER

MO

ST

AT

D

E

F

R

O

S

T

2

5

0

V

 A

C

 8

A

(L

IG

H

T

)

C

O

M

P

2

5

0

V

 A

C

 8

A

R

E

S

IS

T

IV

E

L

O

A

D

9

10

   

  

N

T

C

 

   

   

   

G

N

D

11

12

D

.IN

P

1

Ma

de

 in

 T

urk

ey

Please read this document carefully before using this product. The guarantee will be invalidated if the device is 
damaged by not following instructions detailed in the manual. The company shall not be responsible for any 
damage or losses however caused, which may be experienced as a result of the installation or use of this 
product.

Order Code : EDT2423A -           -                    

1

2

1 - 

Supply Voltage

     230.....

...

230V AC

     

     LV.........10-30V DC /
                    8-24V AC
     

 

     

2 - Modbus 

   

                                         

     

RS...Modbus 

          (Specified at order)
                                                     
                     
                                   
                  

SİSEL MÜHENDİSLİK ELEKTRONİK SAN. VE TİC. A.Ş.

Şerifali Mah. 

 Y.Dudullu  34775

ÜMRANİYE/İSTANBUL-TURKEY
Tel : +90 216 499 46 64 Pbx.    Fax : +90 216 365 74 01
url : www.enda.com.tr

Barbaros Cad. No:18

 35x77mm size.

 On-Off control.

 Three relay outputs for cooling, defrost and fan control.

 Two NTC probe input for cooling and defrost control.

 Offset point can be entered for NTC input.

 Compressor protection parameters can be entered.

 In case of probe failure, compressor operation can be 

   set to ON, OFF or periodic.

 Selectable smart defrost feature.

 Defrost initiated by evaporator temperature, time 

   dependent or manual operation.

 Lower and upper limits of the set point can be set.

 Defrost time and interval can be adjusted.

 Lower and upper alarm limit can be set to dependent 

    on set point.

 Temperature can be displayed in ° C or ° F.

 Digital input.

 Transfer device parameter settings with ENDA key

    - no power-up required.

 RS485 communication features with Modbus RTU 

   protocol (optional).

 CE marked according to European standards.

  

  

 

D

E

F

.N

T

C

 

1

2

3

4

5

6

7

EDT2423A-230
DIGITAL DEFROST 
THERMOSTAT

  230V AC 
50/60Hz  5VA

D

E

F

R

O

S

T

2

5

0

V

 8

A

~

F

A

N

2

5

0

V

 8

A

~

8

9

10

   

  T

H

E

R

.N

T

C

 

  

  

 G

N

D

11 12

  

  

D

.I

N

P

ENDA

 

INDUSTRIAL ELECTRONICS

SN: XXXXXXXXX

E

N

D

A

K

E

Y

8 680407 702541

Made in Turkey

C

O

M

P

2

5

0

V

 8

A

~

SET

SET

 EDT2423A

ENDA

°F

°C

SET

SET

 EDT2423A

ENDA

°F

°C

  230V AC 

50/

60Hz

  

;10-30V DC / 8-24V AC SMPS

D

.I

N

P

14 15 16

ENDA

 

INDUSTRIAL ELECTRONICS

SN: XXXXXXXXX

EDT2423A-230-RS
DIGITAL DEFROST 
THERMOSTAT

E

N

D

A

K

E

Y

11 12 13

        

COM

           

B

        

A

8 680407 702558

  

  

 

D

E

F

.N

T

C

 

1

2

3

4

5

6

7

  230V AC 
50/60Hz  5VA

D

E

F

R

O

S

T

2

5

0

V

 8

A

~

F

A

N

2

5

0

V

 8

A

~

8

9

10

   

  T

H

E

R

.N

T

C

 

  

  

 G

N

D

Made in Turkey

C

O

M

P

2

5

0

V

 8

A

~

Vida sıkma momenti
 0.4-0.5Nm. 

For EDT2423A-X-R ; Relay : NO 250V AC, 8A ,1/2hp, 0.37kW 240V AC  
                                                       
                                             

For EDT2423A-X-R ; Relay : NO 250V AC, 8A ,1/2hp, 0.37kW 240V AC  
                                                       
                                             

Reviews: