Star-delta switching time selection.
Relay status LED
(OUT1 LED lights up when OUT1 relay is turned on).
Cable size
: 1,5mm²
Fuse
F 100 mA
250V AC
NC C NO
U1
U2
NC C NO
ENDA
Y
T
IM
E
Y
R
A
N
G
E
100
200
400
0
500
20
10S
M
10M
H
S
10H
62 mm
66 mm
ATSD02
.4
.6
.8
0
1
.2
O
F
F
T
IM
E
Star connection active time duration selection.
18,5 mm
ENDA
Y
T
IM
E
Y
R
A
N
G
E
100
200
400
0
500
20
10S
M
10M
H
S
10H
ATSD02
.4
.6
.8
0
1
.2
O
F
F
T
IM
E
8 680407 715046
ENDA
ATSD02-UV
ANALOG STAR-DELTA TIMER
SN: XXXXXXXXX
Made in Turkey
OUT1 / OUT2 :
250V AC 10A
RESISTIVE LOAD
POWER :
90-250V AC
50/60Hz
OUT1
NC
NO
C
U1
U2
OUT2
NC
NO
C
9
0
m
m
6
9
m
m
4
5
m
m
8
6
8
0
4
0
7
7
1
5
0
4
6
E
N
D
A
A
T
S
D
0
2
-U
V
A
N
A
L
O
G
S
T
A
R
-D
E
L
T
A
T
IM
E
R
S
N
: X
X
X
X
X
X
X
X
X
M
a
d
e
in
T
u
rk
e
y
O
U
T
1
/
O
U
T
2
:
2
5
0
V
A
C
1
0
A
R
E
S
IS
T
IV
E
L
O
A
D
P
O
W
E
R
:
9
0
-2
5
0
V
A
C
5
0
/6
0
H
z
O
U
T
1
N
C
N
O
C
U
1
U
2
O
U
T
2
N
C
N
O
C
Star connection active remain time selection.
OUT2
OUT1
.4
.6
.8
0
1
.2
10S
M
10M
H
S
10H
2
1
E
NDA
AT
SD
02
O
FF
T
IM
E
O
FF
R
A
N
G
E
.5
.1
.3
.4
.6
.7
.8
.9
0
1
.2
10S
M
10M
H
S
10
H
OF
F T
IM
E
OF
F R
AN
GE
.4
.6
.8
0
1
.2
O
N
T
IM
E
.5
.1
.3
.4
.6
.7
.8
.9
0
1
.2
1
CONNECTION DIAGRAM
ENDA ATSD02
Series timers are rail mounted devices. Make
sure that the device is used only for intended purpose. The
shielding must be grounded on the instrument side. During an
installation, all of the cables that are connected to the device
must be free of energy. The device must be protected against
inadmissible humidity, vibrations, severe soiling and make sure that the
operation temperature is not exceeded. All input and output lines that are not
connected to the supply network must be laid out as shielded and twisted cables.
These cables should not be close to the power cables or components. The
installation and electrical connections must be carried on by a qualified staff and
must be according to the relevant locally applicable regulations.
Supply indicator.
Relay status LED
(OUT2 LED lights up when OUT2 relay is turned on).
1)
Mains supply cords shall meet the requirements of IEC
60227 or IEC 60245.
2)
In accordance with the safety regulations, the power supply
switch shall bring the identification of the relevant instrument
and it should be easily accessible by the operator.
Phase
N
eutral
Fuse should
be connected.
Switch
Holding screw
0.4-0.5Nm.
DIMENSIONS
MONTAGE
For mounting the device to the panel :
Push the device in direction
1
, the rails
provide the key to keeping the rail.
SİSEL MÜHENDİSLİK ELEKTRONİK SAN. VE TİC. A.Ş.
Şerifali Mah.
Y.Dudullu 34775
ÜMRANİYE/İSTANBUL-
TURKEY
Tel : +90 216 499 46 64 Pbx. Fax : +90 216 365 74 01
url : www.enda.com.tr
Barbaros Cad. No:
18
2
/ 2
For removing the device from rail;
Push the rail lock in direction
1
with a
screwdriver and pull the device in
direction
2
.
ATSD02-
EN-02-220103
90-250V AC
or
10-30V DC/8-
24V AC