background image

Star-delta switching time selection.

Relay status LED 
(OUT1 LED lights up when OUT1 relay is turned on).

Cable size 

: 1,5mm²

Fuse

 

F 100 mA 

250V AC

NC C NO

U1

U2

NC C NO

     ENDA

 Y

 T

IM

E

 Y

 R

A

N

G

E

100

200

400

0

500

20

10S

M

10M

H

S

10H

62 mm

66 mm

       

ATSD02

.4

.6

.8

0

1

.2

O

F

F

 T

IM

E

Star connection active time duration selection.

18,5 mm

     ENDA

  

  

Y

 T

IM

E

Y

 R

A

N

G

E

100

200

400

0

500

20

10S

M

10M

H

S

10H

       

ATSD02

.4

.6

.8

0

1

.2

O

F

F

 T

IM

E

8 680407 715046

ENDA

 ATSD02-UV

     ANALOG STAR-DELTA TIMER

SN: XXXXXXXXX

Made in Turkey

OUT1 / OUT2 :

250V AC 10A

RESISTIVE LOAD

POWER :

90-250V AC

50/60Hz

OUT1

NC

NO

C

U1

U2

OUT2

NC

NO

C

9

0

 m

m

6

9

 m

m

4

5

 m

m

8
6

8

0

4

0

7
7

1

5

0

4

6

E

N

D

A

 A

T

S

D

0

2

-U

V

   

  A

N

A

L

O

G

 S

T

A

R

-D

E

L

T

A

 T

IM

E

R

S

N

: X

X

X

X

X

X

X

X

X

M

a

d

e

 in

 T

u

rk

e

y

O

U

T

1

 / 

O

U

T

2

 :

2

5

0

V

 A

C

 1

0

A

R

E

S

IS

T

IV

E

 L

O

A

D

P

O

W
E

R

 :

9

0

-2

5

0

V

 A

C

5

0

/6

0

H

z

O

U

T

1

N

C

N

O

C

U

1

U

2

O

U

T

2

N

C

N

O

C

Star connection active remain time selection.

OUT2

OUT1

.4

.6

.8

0

1

.2

10S

M

10M

H

S

10H

2

1

     E

NDA

 

     AT

SD

02

O

FF

 T

IM

E

O

FF

R

A

N

G

E

.5

.1

.3

.4

.6

.7

.8

.9

0

1

.2

10S

M

10M

H

S

10

H

OF

F T

IM

E

OF

F R

AN

GE

.4

.6

.8

0

1

.2

O

N

 T

IM

E

.5

.1

.3

.4

.6

.7

.8

.9

0

1

.2

1

CONNECTION DIAGRAM

ENDA ATSD02

 Series timers are rail mounted devices. Make 

sure  that  the  device  is  used  only  for  intended  purpose.  The 
shielding must be grounded on the instrument side. During an 
installation, all of the cables that are connected to the device 
must be free of energy. The device must be protected against 

inadmissible  humidity,  vibrations,  severe  soiling  and  make  sure  that  the 
operation temperature is not exceeded. All input and output lines that are not 
connected to the supply network must be laid out as shielded and twisted cables. 
These  cables  should  not  be  close  to  the  power  cables  or  components.  The 
installation and electrical connections must be carried on by a qualified staff and 
must be according to the relevant locally applicable regulations.  

Supply indicator.

Relay status LED 
(OUT2 LED lights up when OUT2 relay is turned on).

1)

 Mains supply cords shall meet the requirements of  IEC   

    60227 or IEC 60245. 

2)

 In accordance with the safety regulations, the power supply

    switch shall bring the identification of the relevant instrument
    and it should be easily accessible by the operator.

Phase

N

eutral

Fuse should

 be connected.

Switch

Holding screw

 0.4-0.5Nm. 

DIMENSIONS

MONTAGE 

For mounting the device to the panel : 

Push the device in direction 

1

 , the rails 

provide the key to keeping the rail.

SİSEL MÜHENDİSLİK ELEKTRONİK SAN. VE TİC. A.Ş.

Şerifali Mah. 

 

Y.Dudullu  34775

ÜMRANİYE/İSTANBUL-

TURKEY

Tel : +90 216 499 46 64 Pbx.    Fax : +90 216 365 74 01
url : www.enda.com.tr

Barbaros Cad. No:

18

 

2

 / 2

For removing the device from rail;

Push the rail lock in direction 

1

 with a 

screwdriver  and pull the device in 
direction 

.

 ATSD02-

EN-02-220103