![Siruba F007K / FSC Electronic Control Parameter Manual Download Page 23](http://html1.mh-extra.com/html/siruba/f007k-fsc/f007k-fsc_electronic-control-parameter-manual_1285098023.webp)
22
Example 2.
a. sewing two opening of underwear, set one program step, manual, feeding speed 50
b. Executes cutter automatically at start of fabric, executes cutter manually at end of
fabric
c. executes cutter after 5 stitches at start of fabric, executes cutter by operator at end of
fabric
d. sewing whenever you need
Step 01 Speed=50 Mode=M
parameter 34
on2
Step 02 Speed=end
f cut
Stitch=5
b cut
Stitch=disable
procedure 1. in sewing mode press
key to enter editing mode
procedure 2. set 50 at speed column in step 01, press
key to set ‘M’ at mode column in step 01
procedure 3. pleases check the speed column must set at “end” in step 02, if not moves to step 02 and
press
key to set “end” at speed column
procedure4. Set f cut column=5stitches; please move to b cut column and press
to disable b cut
function.
procedure5. press
key to return back to sewing mode, press
key enter parameter setting
mode
procedure 6. set parameter34=on2
procedure 7. press
key to return back to sewing mode, illustrated as below