Sirona Sprayvit C8 Operating Instructions Manual Download Page 2

 65 45 490 D3286

2

D3286

.

201.03.15

.

23 04.2015

Table of Contents

Sirona Dental Systems GmbH

Operating Instructions SPRAYVIT / C8 / E / L / M

Table of Contents

1

Before you begin …..................................................................................................

4

1.1

Structure of the document.............................................................................

4

1.1.1

Labeling of information.....................................................................

4

1.1.2

Formats and symbols.......................................................................

5

1.2

Service life of Sirona instruments..................................................................

5

2

Safety information ....................................................................................................

6

3

Technical description................................................................................................

7

3.1

Task ..............................................................................................................

7

3.2

SPRAYVIT / C8 / E / L / M design.................................................................

7

3.3

Technical data...............................................................................................

7

4

Preparation...............................................................................................................

9

4.1

Initial start-up and longer breaks in use ........................................................

9

4.2

Prior to starting the work day ........................................................................

9

4.3

Before each patient .......................................................................................

9

5

Operation..................................................................................................................

10

5.1

Connect the multifunctional syringe to the supply hose ................................

10

5.2

Attach/remove the handle sleeve and nozzle ...............................................

10

5.3

Vent supply lines ...........................................................................................

11

5.4

Applying air, water, or spray..........................................................................

11

6

Follow-up..................................................................................................................

12

6.1

After each treatment session ........................................................................

12

7

Conditioning .............................................................................................................

13

7.1

Conduct pre-disinfection ...............................................................................

13

7.2

Automated cleaning and disinfecting ... ........................................................

13

7.2.1

... with cleaning and disinfection equipment.....................................

13

7.3

Manual cleaning and disinfection ..................................................................

13

7.3.1

Cleaning the nozzle..........................................................................

14

7.4

Sterilizing.......................................................................................................

14

8

Maintenance.............................................................................................................

15

8.1

Replacing O-rings .........................................................................................

15

Summary of Contents for Sprayvit C8

Page 1: ...l f MQKOMNR pmo vsfq L U L b L i L j k W b ErpF Operating instructions...

Page 2: ...on 9 4 1 Initial start up and longer breaks in use 9 4 2 Prior to starting the work day 9 4 3 Before each patient 9 5 Operation 10 5 1 Connect the multifunctional syringe to the supply hose 10 5 2 Att...

Page 3: ...Systems GmbH Table of Contents Operating Instructions SPRAYVIT C8 E L M 8 2 Replacing lamps 15 8 3 Cleaning heating cartridges 15 8 4 Replacing the heating cartridges 16 9 Spare parts and consumables...

Page 4: ...water SPRAYVIT L multifunctional syringe for dental treatment with heated air and heated water and to illuminate the preparation field SPRAYVIT multifunctional syringe for dental treatment with heate...

Page 5: ...ing parts of Sirona instruments have a typical service life of approx 5 years Moving parts of Sirona instruments have a typical service life of approx 3 years No warranty claim can be inferred here as...

Page 6: ...e appropriate hygiene measures e g wear protective gloves Risk of scalding Risk of scalding Test the required media flow amounts 7 before use and conduct a flow rate check 9 Malfunction Damage _ Instr...

Page 7: ...ta SPRAYVIT Multifunctional syringe A Media lever B Serial number Year of manufacture C Valve body D Handle sleeve E Keypad F Nozzle G Light emission only for SPRAYVIT E L M SN xxxxx 20xx SPRAYVIT SPR...

Page 8: ...n W 60 120 max 22 V Air heating power in W 15 max 8 V Heating cartridge electrical resistance in 4 2 0 21 Lamp voltage in V 3 4 0 1 LED current in mA 100 5 SPRAYVIT SPRAYVIT C8 SPRAYVIT E SPRAYVIT L S...

Page 9: ...nge 3 Adjust the media supply at the unit end CAUTION The water may be hot Risk of scalding Set the required media flow rate 4 Ensure that there is perceptible air flow 5 Check the water flow rate It...

Page 10: ...nd electric shock 5 1 Connect the multifunctional syringe to the supply hose SPRAYVIT L Connect SPRAYVIT E L M to the supply hose Exposed voltage CAUTION There may be exposed voltage Do not operate th...

Page 11: ...ut Do not hold or pull on the supply hose 5 3 Vent supply lines Because of the automatic air discharge in Sirona treatment centers for the SPRAYVIT product family the media can be cold at the start of...

Page 12: ...1 Remove any residue e g from impression material or caustic chemicals immediately 2 Purge the water and air channels on the treatment center for 30 seconds 3 Pre disinfect directly at the treatment...

Page 13: ...ame NOTICE SPRAYVIT C8 E L M is not suitable for use with a cleaning and disinfection device 7 3 Manual cleaning and disinfection Immediately after treatment NOTICE Condition immediately or at the lat...

Page 14: ...cked in packaging suitable for sterilization and storage e g paper plastic composite packaging or container Sterilize the multifunctional syringe in the steam sterilizer with saturated water vapor Uni...

Page 15: ...rom lamps CAUTION The lamp can be hot Risk of burns Allow the lamp to cool down 1 Switch the treatment center off at the main switch 2 Detach the handle sleeve from the valve body 10 3 Use a probe or...

Page 16: ...eated media no longer heat up the heating cartridges in the valve body may be burned out Replace the defective heating cartridge The procedure is identical for both heating cartridges depending on the...

Page 17: ...eating cartridge 33 27 132 REF REF SPRAYVIT nozzle G long curved without fiber optic 59 92 206 O ring set SPRAYVIT nozzle 1 attachment tool 10 O rings 5 5 x 1 03 41 76 751 SPRAYVIT nozzle short straig...

Page 18: ...ring set SPRAYVIT nozzle 1 attachment tool 10 O rings 5 5 x 1 03 41 76 751 Casing left water line 60 02 187 Touch button 63 21 728 Small cleaning wires 24 00 232 Halogen lamp brown 59 40 291 REF REF S...

Page 19: ...Storage and transport conditions Operating Instructions SPRAYVIT C8 E L M 10 Storage and transport conditions Protect from moisture Sensitive contents Relative humidity Air pressure Temperature After...

Page 20: ...mbH Operating Instructions SPRAYVIT C8 E L M 11 Disposal According to current information the product does not contain any substances that are hazardous to the environment Disinfected Disinfect the pr...

Page 21: ......

Page 22: ...t K p a p d e OMNR p W ErpF m d aPOUSKOMNKMPKNRKOP MQKOMNR KJk KW MMM MMM p a p d e rp W c PN aJSQSOR _ d K K p a p ii QUPR p a I p NMM I k OUOTP rp l k SR QR QVM aPOUS...

Reviews: