background image

64 65 228 D3637

D3637

.

201.01.01

.

02 15.11.13

19

Sirona Dental Systems GmbH

4 Operation

Operating instructions 22'' Monitor AC, REF 64 65 228 SIVISION digital

4.3 Calling up the "Image Properties" menu

båÖäáëÜ

4.3.3

Switching scaling on/off

1. Select the "Scaling" setting and confirm by pressing the [OK check 

mark].

2. Select the "OFF(Original 

Aspect Ratio)" if you want to maintain the 

aspect ratio of the received image. If necessary, black margins are 

shown on the edge of the image.

Select the "ON(Full)" option if the image received should cover the 

size of the entire screen. If necessary, the image could be displayed 

blurred.

Confirm by pressing the [OK check mark].

The scaling is saved. The on-screen menu is hidden.

Summary of Contents for SIVISION Digital

Page 1: ...l OODD j I obc SQ SR OOU NQKMQKOMNQ pfsfpflk k W b Operating instructions for 22 monitor AC...

Page 2: ...cations and extensions of the system 8 2 5 Danger of electric shock 8 2 6 Electromagnetic compatibility 8 2 7 Dismantling Installation 8 3 Unit description 9 3 1 Standards approvals 9 3 2 Technical da...

Page 3: ...4 4 1 Displaying monitor information 20 4 4 2 Moving the on screen menu window 21 4 4 3 Resetting to factory settings 22 4 4 4 Changing the time before the on screen menu is hidden 23 4 4 5 Selecting...

Page 4: ...success of treatment with your patients For indeed a picture says more than a thousand words These Operating Instructions are designed to assist you prior to initial use and whenever you require infor...

Page 5: ...ed Online portal for technical documents For technical documents we have created an online portal at http www sirona com manuals There you can download these operating instructions and further documen...

Page 6: ...to diagnose X ray images special proof is required from the user in terms of the ambient conditions specifying that the monitor is suitable for diagnostic purposes Please observe the relevant nationa...

Page 7: ...n the Sirona homepage 2 3 Maintenance and repair As manufacturers of dental medical units and in the interest of the operational safety of your system we stress the importance of having maintenance an...

Page 8: ...d The system author assumes responsibility for conformity of the system with 93 42 EEC Directive 2 5 Danger of electric shock To prevent the danger of fire or of electric shock the product must not be...

Page 9: ...y mode VESA 1024 x 768 with 45 116 Hz VESA 1280 x 720 with 45 92 Hz VESA 1600 x 1050 with 50 75 Hz VESA 1920 x 1080 with 60 70 Hz Maximum resolution WUXGA 1920 x 1080 with 60 70 Hz Pixel error rate ac...

Page 10: ...igital Degree of protection against ingress of water Ordinary equipment IP X0 without protection against ingress of water Transport and storage conditions Temperature 20 C 70 C 4 F 158 F Relative humi...

Page 11: ...digital 3 3 Attachment and Connections b 3 3 Attachment and Connections HDMI DisplayPort 100 240 V AC 50 60 Hz 3 5 mm stereo audio Kabelverlegung an die li untere Ecke Dp701 mit Gummit lle in der Mon...

Page 12: ...Softkey Function 1 Back Switches to a higher level menu and hides the on screen menu 2 Left arrow Reduces the value of the selected OSD or selects the previous menu 3 Right arrow Increases the value o...

Page 13: ...o select the required menu and confirm by pressing the OK check mark The settings are displayed for you to select Details regarding the settings are described in the following chapters 3 Select the re...

Page 14: ...5 228 SIVISION digital 4 2 Calling up the Brightness Contrast menu 1 Confirm the softkey for the OK check mark The on screen menu is displayed 2 Use the softkeys Left arrow and Right arrow to select t...

Page 15: ...t arrow and Right arrow to change the brightness value Confirm by pressing the OK check mark The brightness value is saved The on screen menu is hidden 4 2 2 Adjusting the contrast 1 Select the Contra...

Page 16: ...4 65 228 SIVISION digital 4 3 Calling up the Image Properties menu 1 Confirm the softkey for the OK check mark The on screen menu is displayed 2 Use the softkeys Left arrow and Right arrow to select t...

Page 17: ...s Select the Custom option to adjust the RGB values yourself Using preset RGB values Preset Mode option Select the presetting Neutral sRGB standard RGB Reddish or Bluish Confirm by pressing the OK che...

Page 18: ...ating instructions 22 Monitor AC REF 64 65 228 SIVISION digital 4 3 2 Selecting the input signal 1 Select the Input Signal setting and confirm by pressing the OK check mark 2 Select the HDMI option or...

Page 19: ...ng setting and confirm by pressing the OK check mark 2 Select the OFF Original Aspect Ratio if you want to maintain the aspect ratio of the received image If necessary black margins are shown on the e...

Page 20: ...oftkey for the OK check mark The on screen menu is displayed 2 Use the softkeys Left arrow and Right arrow to select the Options menu and confirm by pressing the OK check mark 4 4 1 Displaying monitor...

Page 21: ...m by pressing the OK check mark 2 Select the Default option to select the default menu location Press the OK check mark to confirm your selection the on screen menu is displayed in the default locatio...

Page 22: ...y settings 1 Select the Factory Default setting and confirm by pressing the OK check mark 2 Select Cancel to abort the reset and keep your own settings The on screen menu is hidden when you confirm by...

Page 23: ...ime before the on screen menu is hidden is preset to 10 seconds in the factory default settings 1 Select the Accessibility setting and confirm by pressing the OK check mark 2 Use the softkeys Left arr...

Page 24: ...1 Select the Audio source setting and confirm by pressing the OK check mark 2 Select the Digital option for digital audio transmission via HDMI or display port Select the Analog option for analog aud...

Page 25: ...for a certain period of time This period of time prior to the menu being hidden can be adjusted see Changing the time before the on screen menu is hidden 23 The on screen menu can be instantly hidden...

Page 26: ...2 Care and cleaning of the monitor Remove any dirt and disinfectant residues regularly using a mild commercial cleaning agent The surfaces of the monitor can be wiped with surface disinfectants Surfac...

Page 27: ...ny To initiate return of the electrical device please send a disposal order to enretec GmbH 1 You can find a form for placing a disposal order on the company s homepage www enretec de under the menu i...

Page 28: ...t K p a p d e OMNM p W m d aPSPTKOMNKMNKMNKMO NQKMQKOMNQ KJk KW MMM MMM p a p d e rp W c PN aJSQSOR _ d K K p a p ii QUPR p a I p NMM I k OUOTP rp l k SQ SR OOU aPSPT...

Reviews: