background image

 

Installation guide

 

FM 0120 E 4 

26/07/10 

Rev. 

B

 

 

 

 

 

SIROCO S.A.S. 
10 rue Jean Rostand - Z.I. 
BP 135 
69745 GENAS Cedex 

Tel: +33 (0)4 78 90 96 96 

Fax: +33 (0)4 78 90 15 98 

www.siroco.fr 

Page 6 of 6 

 

Fault found 

Possible cause 

Action to take 

Vehicle engine is not 
running 

Start engine. 

Cooling water still cold 

Wait until the engine reaches operating temperature 

Water valve closed 

See the vehicle manufacturer’s operating 
instructions. 

Water lines kinked or 
squashed 

Eliminate fault by installing correctly. 

Heating doesn’t function 

Water pump pressure 
insufficient 

Heat exchanger does not have cooling water flowing 
through. Install additional pump or more powerful 
one. 

Volumetric air flow from 
blower is too low 

See action to take under “Blower” 

Water flow rate through 
heat exchanger is too 
low 

Water lines kinked or squashed. Relay hoses. Water 
pump pressure too low (see above for action). 

Flush-out water circuit. 

Air in heat exchanger 

When the pumping pressure is sufficient the heater is 
self bleeding. Install additional or more powerful 
water pump. 

Unit is underdimensioned  Install a more powerful unit. 
Insufficient pumped 
water pressure 

Install additional pump or a more powerful one. 

Reduced heating 
performance 

Heat exchanger severely 
contaminated 

Carefully clean avoiding damage which can lead to 
leaks. 

 Products 

which

 have already been pulling appart are not covered by guaratee.

 

 

5 - Security advice 

 

Consider the following advice for your own safety : 
 

 

Installation must only be done by well-formed and authorized specialists. 

 

Product must operate on a well-ventilated place. 

 

Products  have  to  be  used  only  according  to  the  intended  use.  Products  shall  not  used  in 

improper environment. Pay attention to guarantee. 

 

Before using products, ensure that regulations and laws are strictly adhered according to the 

country. 

 

For  security  reasons  (fire  hazards),  fuses  with  required  amperage  must  be  used  to  protect 

electrical connections. 

 

Cut electrical connections before working on product. 

 

Do not get into contact with the heat exchanger and its connections. 

 

Do not grip into the unit and do not put objects inside. 

 

Summary of Contents for ARIZONA LN S

Page 1: ...v B Page 1 of 6 ARIZONA LN S 1 Device description 2 Operation 3 Mounting information 4 Trouble shooting 5 Security advice SIROCO S A S 10 rue Jean Rostand Z I BP 315 69745 GENAS Cedex Tel 33 0 4 78 90 96 96 Fax 33 0 4 78 90 15 98 www siroco fr ...

Page 2: ...n input air supply on heater back an output air supply on front plate and an input output cooling water supply ARIZONA LN S front plate is available in different colors white grey anthracite or black Heater is available in 12 V or 24 V with connections pipes diameters of 16 mm Product part numbers ARIZONA LN S Voltage Front plate color Part number White 0120 0351 Grey 0120 0352 Anthracite 0120 035...

Page 3: ...ce Operating temperature have to be between 30 C and 80 C Cooling fluid must be antifreeze and anticorrosive for copper and aluminum Use a cooling fluid officially recognize by automotive manufacturers Technical data Voltage Electrical power Weight Nominal air flow Heating capacity Sound level 12 24 V 12 W 1 4 kg 110 m h 3 kW 50 dB Optimum heating capacity is reached with air inlet temperature of ...

Page 4: ...ed screws Blower motor axis should rather be in horizontal position on the vehicle Do not drill heater s body so as not to damage heat exchanger Connect water input and output by using cooling pipes with corresponding diameter Use suitable clamping rings There is no preferential cooling water direction Check for leaks in water Fixation stand 2 3 210 x 170 mm cut out 4 not supplied screws 4 x Ø 3 7...

Page 5: ...he circuit diagram and if necessary assemble correctly Blower switch defective Replace the switch with a new original component Blockage in fan unit Rectify cause of blockage e g object in impeller If necessary order new unit Blower not working Blower motor defective Replace plastic part motor No blower power Check connection on blower switch Blower doesn t operate at all speeds Defective resistan...

Page 6: ...re is sufficient the heater is self bleeding Install additional or more powerful water pump Unit is underdimensioned Install a more powerful unit Insufficient pumped water pressure Install additional pump or a more powerful one Reduced heating performance Heat exchanger severely contaminated Carefully clean avoiding damage which can lead to leaks Products which have already been pulling appart are...

Reviews: