background image

 

Installation guide

 

FM 0120 E 4 

26/07/10 

Rev. 

B

 

 

 

 

 

Page 1 of 6

 

 

 

ARIZONA LN S 

 

 
 
1 - Device description 
 
2 - Operation 
 
3 - Mounting information 
 
4 - Trouble shooting 
 
5 - Security advice 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

SIROCO S.A.S. 

10 rue Jean Rostand - Z.I. 

BP 315 

69745 GENAS Cedex 

Tel: +33 (0)4 78 90 96 96 

Fax: +33 (0)4 78 90 15 98 

www.siroco.fr

 

Summary of Contents for ARIZONA LN S

Page 1: ...v B Page 1 of 6 ARIZONA LN S 1 Device description 2 Operation 3 Mounting information 4 Trouble shooting 5 Security advice SIROCO S A S 10 rue Jean Rostand Z I BP 315 69745 GENAS Cedex Tel 33 0 4 78 90 96 96 Fax 33 0 4 78 90 15 98 www siroco fr ...

Page 2: ...n input air supply on heater back an output air supply on front plate and an input output cooling water supply ARIZONA LN S front plate is available in different colors white grey anthracite or black Heater is available in 12 V or 24 V with connections pipes diameters of 16 mm Product part numbers ARIZONA LN S Voltage Front plate color Part number White 0120 0351 Grey 0120 0352 Anthracite 0120 035...

Page 3: ...ce Operating temperature have to be between 30 C and 80 C Cooling fluid must be antifreeze and anticorrosive for copper and aluminum Use a cooling fluid officially recognize by automotive manufacturers Technical data Voltage Electrical power Weight Nominal air flow Heating capacity Sound level 12 24 V 12 W 1 4 kg 110 m h 3 kW 50 dB Optimum heating capacity is reached with air inlet temperature of ...

Page 4: ...ed screws Blower motor axis should rather be in horizontal position on the vehicle Do not drill heater s body so as not to damage heat exchanger Connect water input and output by using cooling pipes with corresponding diameter Use suitable clamping rings There is no preferential cooling water direction Check for leaks in water Fixation stand 2 3 210 x 170 mm cut out 4 not supplied screws 4 x Ø 3 7...

Page 5: ...he circuit diagram and if necessary assemble correctly Blower switch defective Replace the switch with a new original component Blockage in fan unit Rectify cause of blockage e g object in impeller If necessary order new unit Blower not working Blower motor defective Replace plastic part motor No blower power Check connection on blower switch Blower doesn t operate at all speeds Defective resistan...

Page 6: ...re is sufficient the heater is self bleeding Install additional or more powerful water pump Unit is underdimensioned Install a more powerful unit Insufficient pumped water pressure Install additional pump or a more powerful one Reduced heating performance Heat exchanger severely contaminated Carefully clean avoiding damage which can lead to leaks Products which have already been pulling appart are...

Reviews: