USES
The appliance is already arranged both for filte-
ring and for suction performances.
- In its
filtering version
(Pic. 1), the air and fu-
mes conveyed by the appliance are depured both
by a grease filter and by an active coal filter, and
put again into circulation through the hole made
on the top of the cabinet.
- In its
sucking version
(Pic. 2), fumes are di-
rectly conveyed outside, through an evacuation
duct connected with the superior part of the wall
or the ceiling. Both coal filter and air deflector are
not necessary in this case.
12
INSTALLATION
In order to ease the installation of the product in
side the cabinet, it is recommended to remove
the glass (mod. SM924 - SM927), unscrewing the
four M3x10 screws as shown in Pic. 10.
Before installing the appliance, make sure that
none of the parts is damaged in any way. In case
of damaged parts, contact your retailer and do
not proceed with installation.
Read all of the following instructions with care be-
fore installing the appliance.
- Before installing the appliance, remuve the me-
tal grase filter. It can be removed by pushing its
special handle toward the back-side of the coo-
ker hood and turning the filter downwards so to
unfasten it from its slot (Pic. 3).
To install the appliance please respect the follow
instructions.
The appliance must be install by competent au-
thorities. In order to do not damage the electronic
parts of the appliance please do not use added
screws.
Essential precautions to respect before in- stal-
ling the appliance are the following:
- Prepare the power supply.
- Prepare a hole for the exhaust of the air both in
the filtering and in the exhau sting version.
- Use an exhausting pipe whose maximum length
does not exceed 5 meters.
- Do not use screws to fix the outlet pipe to the
cooker hoods.
- Limit the no. of elbows in the piping , since each
elbow reduces the aspiration efficiency of 1 linear
meter. (Ex.: if you use no. 2 x90 ° elbows, the
length of pi ping l must not exceed 3 meters)
- Avoid abrupt direction changes.
- Use a 150 mm or 200 mm constant dia meter
pipe for the whole length.
- Use piping approved by standards in for ce.
- In the units equipped with 2 motors ple ase use
a 200mm constant diameter pipe for the whole
length.
To have made a cut-out on the bottom of the ca-
binet which is suitable to hold the appliance in
position (Fig. 4).
Summary of Contents for SM923 52
Page 2: ...2...
Page 3: ...1 3 2 3 4...
Page 4: ...4 8 9 7 6 5 10...
Page 5: ...5 14 13 12 11...
Page 6: ...INDICE Avvertenze Sistema d uso Installazione Funzionamento Manutenzione IT 6...
Page 10: ...CONTENTS Warnings Uses Installation Working Maintenance GB 10...
Page 16: ...90000702324 03 21...