For ease of installation the SEM11 motor can be fixed
inside the roof cavity or positioned underneath the floor of
the house, providing the SEM motor is protected from the
elements. The SEM motor uses mounting brackets to fix it
securely to the predetermined location. This location must
be accessible.
Motor/ducting and electrical connection installation
1. After deciding the location of the motor (no back-
to-back installation, no closer than 2 metres and no
further than 7 metres from the rangehood). The motor
should ideally be located closer to the venting point
for maximum air movement. Insert the supplied rubber
anti-vibration caps into holes on the supplied brackets.
The rubber caps must be inserted on the side of the
bracket that fixes to the structure. These caps will
reduce any vibration and reduce the noise level of the
motor.
(Fig 1. [1C])
2. Using the supplied screws connect the brackets (Fig.
1A) to the motor (Fig. 1B)
3. Align the SEM motor brackets with predetermined
location and mark the points required for pre-drilling of
the holes.
4. After pre-drilling the holes, insert the plastic dowels
(Fig. 2A) and then fix in place using the supplied
screws (Fig. 2B).
Make sure you have taken note of the inwards and
outwards arrows on the SEM motor and the motor is
positioned accordingly.
5. Connect a length of Sirius 150mm ducting to the collar
of the rangehood and secure with a URC25/215 ring
clamp (if using semi-rigid ducting).
6. Run the length of ducting to the location of the SEM
motor and secure to the inlet collar and secure with
another URC25/215 ring clamp (if using semi-rigid
ducting).
7. Run another length of 150mm ducting from the outlet
collar on the SEM motor to the predetermined exit
point/vent.
See Sirius website for wall, roof, and eave venting
options or contact your nearest Sirius retail partner.
8. The SEM motor has a 7 metre long cable with
colour-coded wiring. Follow the MOTOR WIRING
CONNECTION instructions on page 4 of this manual
to connect the motor to the rangehood.
9. The motor will draw power itself from the rangehood
which is plugged into a 10AMP powerpoint located
within 1 metre of the rangehood.
SEM11 MOTOR
(Fig.1)
Roof venting option shown
(Fig. 2)
1A
2A
2A
2B
2B
2A
1B
1C
165mm
150mm
150mm
150mm
300mm
Air direction
Power cord
250mm
300mm
200mm
100mm
50mm
150mm
90mm
125mm
125mm