background image

1

S-DD2-L FLUSH TOP

DOWNDRAFT INSTALLATION INSTRUCTIONS FOR

SEM 1, SEM 2, SEM 7, & SEM 8 motors

Congratulations on your purchase!

Thank you for choosing a Sirius product.

SDD2 L EMTC 580 

 

 

EAN #9351116001063

SDD2 L EMTC 880 

 

 

EAN #9351116001094

SDD2 L EMTC 1180 

 

 

EAN #9351116001193

SDD2 L EMTC 580 WH   

 

EAN #9351116001070

SDD2 L EMTC 880 WH   

 

EAN #9351116001278

SDD2 L EMTC 1180 WH  

 

EAN #9351116001285

Summary of Contents for 9351116001063

Page 1: ...s Congratulations on your purchase Thank you for choosing a Sirius product SDD2 L EMTC 580 EAN 9351116001063 SDD2 L EMTC 880 EAN 9351116001094 SDD2 L EMTC 1180 EAN 9351116001193 SDD2 L EMTC 580 WH EAN...

Page 2: ...ase contact your local city office your household waste disposal service or the shop where you purchased the product This appliance is marked according to the European directive 2002 96 EC on waste el...

Page 3: ...gas hobs without pots or pans on them under the hood itself the flames sucked into the hood might damage the appliance Frying under the appliance must be done under constant supervision as hot oils an...

Page 4: ...APPLIANCE DIAGRAMS Side bottom venting SEM 1 SEM 2 motor Side bottom venting SEM 7 SEM 8 motor Front rear venting SEM 1 SEM 2 SEM 7 SEM 8 motor Side bottom venting SEM 10 motor DUCTING TYPES pg 7 pg 8...

Page 5: ...a duct used for fumes discharge or discharge from appliances using gas or other combustible materials Air cannot be ducted into roof space The use of discontinued ducts is not allowed without the app...

Page 6: ...air capacity of 1 linear meter Ex if you use no 2 x 90 elbows the length of piping should not exceed 5 meters Avoid abrupt direction changes Optimum angle 45 when required Use a 150 mm for 580mm model...

Page 7: ...ts Part F supplied with the product Insert the brackets in the lower side of the downdraft in such a way that there is a 2 mm distance between the lower side of bracket and the bottom of the cabinet T...

Page 8: ...piece Part I 2A Secure to the motor with a universal ring clamp Part G See page 12 for ducting from motor to vent N A for SEM 2 motors This step covers ducting for SDD2 L EMTC 580 models only For 880m...

Page 9: ...to round adapter Part A then connect length of ducting Part K 2 to the 200mm outlet 2B Secure to the motor with a universal ring clamp Part G See page 12 for ducting to vent N A for SEM 7 motor STEP...

Page 10: ...ing the special fixing brackets Part F supplied with the product Insert the brackets in the lower side of the downdraft in such a way that there is a 2 mm distance between the lower side of bracket an...

Page 11: ...ly onto the collar on the front adaptor plate Part D 3 Fix in place using a universal ring clamp Part G S DD2 L FLUSH TOP INSTALLATION GUIDE PART G PART G PART K 1 K 2 PART K 1 K 2 PART K 1 K 2 SEM 2...

Page 12: ...motor is to be no less than 2 metres away from the downdraft Failure to do so may result in additional noise level of the downdraft Maximum distance is 7 metres however 3 5 metres is optimum to minimi...

Page 13: ...h a CEI 60083 approved power socket 10AMP power socket which must remain accessible after installation in compliance with installation regulations We decline any responsibility in case of accidents ca...

Page 14: ...After the next 3 cycles the downdraft will carry out its self calibration Stand by When the extractable unit is closed and the light is switched off the control panel after 6 seconds activates the Sta...

Page 15: ...sent a fire risk If frying or cooking with oil the filers need to be cleaned more regularly Refit the grease filters and front panel making sure that the panel is properly fitted at the sides so that...

Page 16: ...Pull the panel out of the rangehood Disconnect the cable Twist the light globe and pull to remove 2 Remove the two screw under the top panel and the three on the back five screws in total 4 Remove the...

Page 17: ...TOR PIECE GDC 200 K K 1 DUCTING 150MM K 2 DUCTING 200MM SRPRO 30 150 SRPRO 30 200 L DUCTING CONNECTOR FOR SEM 10 INSTALLATIONS ONLY Part no FLANGE PARTS LIST AFTER SALES SERVICE Any maintenance operat...

Page 18: ...ducting adaptor SPS 81020 PART B Bottom side cover collar PART C Bottom side exit connector PART D Front rear vent adaptor SPS 20059120071 PART F PART E Upright fixing brackets Front rear vent cover p...

Page 19: ...purchased separately PART H 150mm to 200mm Duct expander GDR 150 200 PART I 150mm diameter connector piece GDC 150 PART J 200mm diameter connector piece GDC 200 PART L Ducting connector for SEM 10 in...

Page 20: ...Professional Stockists nationwide For the latest list of Sirius Stockists near you please refer to www siriusbrand com All efforts have been made to ensure that the information provided in this brochu...

Reviews: