Default Configuration
Figure 9.
Default Configuration
Use the following configuration setup to get started with the ZOOM evaluation platform.
The following jumpers are used to implement the following functions:
»
Connect Vin power to the main power supply to power the main board
»
Connect the GSM registration status to the red LED to display network registration
»
Connect auto power on jumper to auto power up the modem when power is applied.
1
3
2
No.
Item
Description
1
GPIO1 to red status LED
connection
Used to display GSM network registration status when GPIO1 is
used in alternate function mode
AT#GPIO=1,0,2
AT#SLED=2
AT#SLEDSAV
2
Auto power on mode connection
Modem will power up automatically when main power is applied
3
Vin to main board power
connection
Used to measure current usage on board or directly power the
board when jumper is fitted