2

Traffic 

Arrow 

Function

s:

Selecting the 

Traffic 

Arrow Sequence

 and Warning Flash Patterns

:

Th

is lightbar

 is designed to offer user selectable traffic directing flash sequences.  Each of the 

Traffic 

Arrow functions 

(LEFT, CENTER-OUT, RIGHT) can be configured individually for unique sequences and flash rates.  This allows the greatest flexibility when controlling 

the various light bar configurations available.    The lightbar will come from the factory with Building Fast

 (Mode 1)

 as the default for LEFT, CENTER-

OUT and RIGHT.   If it is desired to change the sequence for any of the functions, follow the configuration procedure below.

STEP 1:

 Power-up the light bar.  Apply +power to the appropriate wire for the 

Traffic 

Arrow function that you wish to configure (LEFT - 

RED

, CENTER-

OUT - 

RED

 and 

ORG

, RIGHT - 

ORG

).  

Programming will not work if more than one function is selected at a time.

STEP 2: 

Continue applying power to the wire from Step 1.  Refer to Table 

3

 for the available 

Traffic 

Arrow function.  To increment to the next 

mode

momentarily hold the BLK/RED wire to +power for less than two seconds and then release.  The four corner light heads will turn on steady to indicate 

that the function has been incremented. To decrement to the previous 

mode

, momentarily hold the BLK/RED wire to +power for two to four seconds 

and then release.  The four corner light heads will turn on steady and then turn off to indicate that the 

mode

 has been decremented. After the BLK/RED 

wire has been released, the new 

mode

 will begin to operate and is automatically stored each time.  Notice that for the LEFT, CENTER-OUT and 

RIGHT functions there are four sequence 

(mode) 

choices (Building, Building with 3 Flash, Traveling Ball with 3 flash, and Build/Collapse) and three 

speeds (Fast, Medium and Slow).  There are a total of 

four

 select

able modes

 for each 

of the 4 

function

s

 and then you return to the top selection

 (Mode 

1)

. Flash 

patterns

 marked with an asterisk “*” can be selected in Fast, Medium or Slow flash rate.

NOTE:  To restore the Factory Default 

Mode

 for any

 of the 4

 

T

raffic

 Arrow

 

Functions

, hold the BLK/RED wire to +power for more 

than four 

seconds.  The four corner light heads will turn on steady, turn off and then turn on steady again to indicate that the Factory Default 

Mode

 

has been restored.  Only the 

T

raffic

 Arrow

 

Function

 that is activated will be restored.

 You can only restore the Factory Default to 1 Function 

at a time.

STEP 3:

  Repeat steps 1 

and

 2 for 

each Traffic 

Arrow 

F

unction as desired.

TABLE 

3

: TRAFFIC DIRECTING 

&

 TRAFFIC WARNING FLASH FUNCTION

S

MODE

LEFT

 (Red Wire)

CENTER-OUT

 (Red & Orange)

 

RIGHT

 (Orange Wire)

1

Building

Building

Building

2

Building, 3 Flash

Building, 3 Flash

Building, 3 Flash

3

Traveling Ball, 3

Traveling Ball, 3

Traveling Ball, 3

4

Build/Collapse

Build/Collapse

Build/Collapse

All sequences have a fast,

medium or slow speed.

 All sequences have a fast, medium or 

slow speed.

All sequences have a fast, medium or 

slow speed.

Summary of Contents for SNLBL10

Page 1: ...for the Sirennet SNLBL10 47 LED Lightbar Contents Introduction Fusing Considerations Warnings 2 Installation Mounting 3 4 Maintenance 5 Warning Signal Modules 5 6 3 Level Modes of Operation 5 Selectin...

Page 2: ...ire size and other recommendations of the manufacturer and be protected from moving parts and hot surfaces Looms grommets cable ties and similar installation hardware should be used to anchor and prot...

Page 3: ...his time Place the light bar upside down on a table or other work surface being careful not to scratch the lenses Slide the 5 16 carriage bolts into the frame Secure the mounting brackets finger tight...

Page 4: ...support the weight of the light bar Place the unit on the roof of the vehicle Place a soft pad in the center of the roof to protect the paint The mounting brackets must be placed so that they are res...

Page 5: ...ual switches make sure to configure all possible switch combinations Repeat steps 1 through 3 for each of the seven possible 3 Level modes as desired TABLE 1 3 LEVEL MODES OF OPERATION MODE NUMBER WIR...

Page 6: ...s will turn on steady to indicate that the flash sequence has been incremented To decrement to the previous pattern momentarily hold the appropriate pattern selection wire to power for two to four sec...

Page 7: ...will turn on steady and then turn off to indicate that the mode has been decremented After the BLK RED wire has been released the new mode will begin to operate and is automatically stored each time N...

Page 8: ...To decrement to the previous rate momentarily hold the BLK RED wire to power for two to four seconds and then release The four corner light heads will turn on steady and then turn off to indicate that...

Page 9: ...ected to connectors P9 P10 The Steady Burn outputs are enabled by the 3 Level control inputs The lightbar may be configured so that Steady Burn light heads are on when either L1 L2 or L3 are active JP...

Page 10: ...ght Right Arrow overrides L1 L2 L3 for rear of lightbar Red Arrow Left Flashing Arrow overrides L1 L2 L3 for rear of lightbar Green White Front Cut Off Blacks Out Front Facing LEDs Blue Black Rear Cut...

Page 11: ...Page 11 of 12 Notes...

Page 12: ...ER S EXCLUSIVE REMEDY IN CONTRACT TORT INCLUDING NEGLIGENCE OR UNDER ANY OTHER THEORY AGAINST MANUFACTURER REGARDING THE PRODUCT AND ITS USE SHALL BE AT MANUFACTURER S DISCRETION THE REPLACEMENT OR RE...

Reviews: