SIP Medusa Ti-1002 Manual Download Page 6

  SAFETY INSTRUCTIONS….cont 

Flammable: 

The fuel used to run this generator (unleaded petrol) is 

highly flammable. Never re-fuel the generator whilst it is still running. 
Store un used fuel safely and away from children and in accordance 
with local regulations / laws.  

Electrical current from the generator may "back feed" into the home's electrical sys-
tem. 
It could cause damage or fire to the building, the generator as well as anything con-
nected to it. 
Should a generator be required to be connected to any electrical system, it must be 
installed by a suitably qualified electrician who can warn you of any dangers that may 
occur.  
Incorrectly installed generators can also cause personal injury. For example, if a power 
company employee is working on an electrical line believing it to be "dead" and cur-
rent created by the generator is in the line, shock or electrocution may occur. 
The key to better safeguard against these dangers is professional installation by a 
qualified electrician and the installation of a generator transfer switch. 
Keep in mind a generator burns fuel and must be run in a well ventilated area, it must 
not be run in a garage or other outbuilding. 
Cords used to connect the generator to the lights and appliances must be correctly 
sized to prevent overheating or damage to the equipment as well, again if you are 
unsure ask a suitably qualified electrician. 

Caution: 

Never attempt to connect the generator directly to the electrical 

system of any building / structure which is connected to the main grid.

 

1. Use the ground terminal (see picture above) on the generator to connect the unit to 
a suitable ground source. Securely fasten the end terminal of the ground wire to the 
ground terminal on the generator. 
2. The ground wire should be made of more than 0.75 square millimetre wire. Too thin 

Grounding instructions:

 

Earth / Ground 

Terminal 

27 

  PARTS LIST….cont 

119 

Washer M4 

PW01-00064 

119 

Washer M4 

PW01-00064 

120 

Bracket Connector 

PW01-00177 

120 

Bracket Connector 

PW01-00177 

121 

Muffler Shield Left 

PW01-00178 

121 

Muffler Shield Left 

PW01-00178 

122 

Canister Bracket 

PW01-00179 

122 

Canister Bracket 

PW01-00179 

123 

Flange Bolt M5x16 

PW01-00013 

123 

Flange Bolt M5x16 

PW01-00013 

124 

Canister    

PW01-00180 

124 

Canister    

PW01-00180 

125 

Canister Bracket 

PW01-00181 

125 

Canister Bracket 

PW01-00181 

126 

Flange Bolt M5x12 

PW01-00039 

126 

Flange Bolt M5x12 

PW01-00039 

127 

Clip 8mm 

PW01-00022 

127 

Clip 8mm 

PW01-00022 

128 

Clip 10mm 

PW01-00048 

128 

Clip 10mm 

PW01-00048 

129 

Canister Tube 

PW01-00182 

129 

Canister Tube 

PW01-00182 

130 

Canister Tube 

PW01-00183 

130 

Canister Tube 

PW01-00183 

131 

Clip 9mm 

PW01-00020 

131 

Clip 9mm 

PW01-00020 

132 

Flange Bolt M5 

PW01-00077 

132 

Flange Bolt M5 

PW01-00077 

118 

Self Tapping Screw 4x12 

PW01-00079 

 

 

 

Summary of Contents for Medusa Ti-1002

Page 1: ...the local amenity tip and place into the appropriate recycling bin Never dispose of electrical equipment or batteries in with your domestic waste If your supplier offers a disposal facil ity please us...

Page 2: ...d 2006 95 EC Low Voltage Directive 98 37 EC Machinery Directive 2004 108 EC EMC Directive 97 68 EC Emissions From Non road Mobile Machinery As Amended By 2002 88 EC 2006 96 EC 200 14 EC Noise Emission...

Page 3: ...s 7 Guarantee 8 Technical Specifications 9 Getting To Know Your Generator 11 Operating Instructions 18 Maintenance 20 Exploded Drawing Ti 1002 21 Parts List Ti 1002 23 Exploded Drawing Ti 2002 24 Part...

Page 4: ...oose clothing or jewellery to start or operate the gen erator Loose clothing or jewellery may become entangled in moving components causing equipment damage and or personal injury 10 Be aware of movin...

Page 5: ...ator with power cords or by any means to move it only move the generator with the carrying handles 31 Never cover the generator or restrict the exhaust or air flow in any way 32 Always ensure that the...

Page 6: ...overheating or damage to the equipment as well again if you are unsure ask a suitably qualified electrician Caution Never attempt to connect the generator directly to the electrical system of any buil...

Page 7: ...M5x16 PW01 00170 108 18 Washer M5 PW01 00170 108 17 Spring Washer M5 PW01 00170 109 Hex Bolt M6x30 PW01 00171 108 18 Washer M5 PW01 00170 110 Flange Bolt M5x8 PW01 00172 109 Hex Bolt M6x30 PW01 00171...

Page 8: ...00151 54 25 Step Motor Support PW01 00140 77 Cross Head Screw M5x30 PW01 00152 54 26 Choke Lever Assembly PW01 00140 78 Maintenance Cover Left PW01 00153 54 27 Washer M3 PW01 00140 79 Bolt M6x16 PW01...

Page 9: ...00018 51 Washer M6 PW01 00086 18 Recoil PW01 00117 52 Spring Washer M6 PW01 00087 19 Flange Bolt M6x12 PW01 00008 53 Flange Bolt M6x25 PW01 00139 20 Fuel Tank Cap PW01 00118 54 Carburettor Complete PW...

Page 10: ...Recoil Starter 3 Fuel Cap 12 DC Socket 4 Primer Bowl 13 DC Circuit Breaker 5 Fuel Valve 14 AC Socket 6 Maintenance Panel A 15 Low Oil Indicator 7 Engine Switch 16 Pilot Power Indicator 8 Earth Ground...

Page 11: ...77 129 Flange Bolt M10x1 PW01 00100 96 Air Filter Cover PW01 00078 130 Fan Hood PW01 00101 97 Self Tapping Screw M4x12 PW01 00079 131 Self Tapping Screw 3 5x12 PW01 00102 98 Plastic Case Left PW01 000...

Page 12: ...00027 8 Flange Bolt M6x12 PW01 00008 42 Tube Sleeve PW01 00035 9 Starter Cover PW01 00009 43 Fuel Tank Rubber Seal PW01 00036 10 Washer M8 PW01 00010 44 Inverter Block PW01 00037 11 Flange Bolt M6x16...

Page 13: ...on 1 position Step 2 Turn the fuel tap to the on position Step 3 Slide the choke lever to the left Note The choke may not be needed if the engine is already warm or the ambient temperature is hot 039...

Page 14: ...n unclean area 1 Remove the M6 screws and open the muffler cover 2 Remove the two M4 screws on the spark arrestor 3 Take out the spark arrestor 4 Check the spark arrestor clean or replace if necessary...

Page 15: ...heck the overall condition of the plug and replace if damaged 7 Reinstall the plug spark plug cap and maintenance panel Check The Fuel Tank Filter periodically Just under the fuel cap is a fuel filter...

Page 16: ...nerator In an emergency simply press the engine switch to the off position In normal conditions Remove any load from the generator Turn the fuel tap to off Press the engine switch to the off position...