8
CIRCUIT DIAGRAM
5
OPERATING INSTRUCTIONS
Specifications and Scope of Applicability (see table 1 below):
Table 1
Functional Characteristics.
The battery charger is equipped with protection in case of:
overloads (too much current delivered towards the battery).
short circuit (charging clamps set in contact with one another).
polarity reversal of the battery.
For battery chargers equipped with fuses, it is necessary, in case of substitution of fus-
es, to use spares having the same nominal current value as the original fuse.
WARNING:
If fuses with current values different from those given are used; a fire hazard
and / or electric shock and damage to the charger and anything connected to it
could occur. For the same reason do not substitute the fuse with copper (or other ma-
terials ) to bridge the fuse terminals.
The substitution of the fuse is to be done when the charger is disconnected from the
mains supply.
Technical Indexes.
Input voltage: 230V ~50Hz
output current (see table 2)
Table 2
Model
Minimum capacity of lead-acid battery suitable for charging
05284
Min.: 12v 30Ah, Min.: 24v 20Ah
05286
Min.: 12v 30Ah, Min.: 24v 30Ah
Operating Environment and Placement.
1. The charger should be placed in a well-ventilated and dry place free from direct
sunshine and corrosive gas and away from heat source. Do not expose charger
to rain and snow.
Warning:
it should be as far as possible away from battery and
on a flat, stable surface to avoid falling.
2. It is unsafe to directly place the charger on the battery or battery on the charger.
Charging output voltage.
05284
05286
12v
20 amp (Max.)
45 amps (Max.)
24v
12 amp (Max.)
45 amps (Max.)